| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | aerotracer |
| Detection Principle | Matrix-based Multi-Channel Mixed Sensor Array |
| Sample Flow Rate | 50–100 mL/min |
| Detection Time | < 60 seconds |
| Detectable Substances | Aviation Engine Lubricants, Hydraulic Fluids (e.g., MIL-PRF-83282/87257), De-icing Fluids (Type I/II/IV), Corrosion Inhibitors, Adhesives, Jet Fuel (Jet A/A-1) |
| Display | Graphical LCD Interface |
| Dimensions | 395 × 112 × 210 mm |
| Weight | 4.2 kg (without battery) |
| Operating Temperature | 0–45 °C |
| Relative Humidity | 5–95 % RH (non-condensing) |
| Power Supply | 110–240 VAC, 30 W or Rechargeable Battery (4 h standby) |
| Communication | RS232 Serial Interface |
| Data Storage | Removable 1 GB miniSD Card |
| Software | WinMuster AT (Offline & Real-Time Data Analysis) |
| OS Compatibility | Windows XP, Vista, 7 |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | COOLJETTER |
| Quotation | Available Upon Request |
| Dimensions | Not Applicable (Wall/Ceiling-Mounted Fixed Installation) |
| Reservoir Capacity | Not Specified |
| 雾化输出速率 | Not Specified |
| Sensing Distance | Not Specified |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DRY-FOG |
| Quotation | Upon Request |
| Dimensions | Not Applicable (Wearable, Ergonomic Design) |
| Reservoir Capacity | Integrated Dual-Compartment Cartridge System (Compatible with Standard 1–2 L Disinfectant Cartridges) |
| 雾 Output Rate | ≤2 L/h (Adjustable via Microprocessor-Controlled Pneumatic Atomization) |
| Detection Range | 0–30 cm (Infrared Proximity Sensor, Auto-Triggered Dispensing) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±2% FS |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 s |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC, user-selectable target odorants (1–2), and dimensionless odor unit (OU) concentration |
| Communication Interfaces | WiFi, GSM, GPRS, 3G, Ethernet |
| Data Management | Cloud database, local LAN, or open-network deployment |
| Compliance Ready | Designed for integration into GLP/GMP- and ISO 16000-compliant environmental monitoring workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | EDU3 |
| Product Type | Olfactory Analysis System (Electronic Nose) |
| Adsorbent Compatibility | Multiple proprietary sorbents |
| Sample Flow Rate | 0.2–0.5 L/min (programmable) |
| Sample Temperature Range | 30–100 °C (adjustable) |
| Desorption Flow Rate | 50–100 mL/min (adjustable) |
| Desorption Temperature | >250 °C (adjustable) |
| Injection Port Temperature | >150 °C (heated transfer line) |
| Enrichment Factor | 10–1,000× (compound- and time-dependent) |
| Interface Compatibility | PEN3 electronic nose, GC, GC-MS, MS |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-F |
| Detection Principle | Multi-Sensor Fusion (IMS, PID, MOS, EC) + Pattern Recognition Algorithm |
| Detection Time | 2–60 s |
| Detection Range | 1 ppb – 10 ppm (gas-dependent) |
| Sample Interface | Dedicated Container Probe with Integrated Auto-Sampling Pump |
| Operating Temperature | −30 °C to +50 °C |
| Relative Humidity Range | 5–95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion Battery (30 W, 4 h runtime) |
| Dimensions | 39.5 × 11.2 × 21 cm |
| Weight | 4.2 kg |
| Data Interfaces | RS-232, Ethernet, Wireless Transmission |
| Sensor Channels | 8-channel parallel acquisition (dual IMS, dual PID, dual MOS, dual EC) |
| Database | Preloaded Library of TICs & Fumigants (Expandable) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-F |
| Weight | 2 kg |
| Sampling Method | Automatic Continuous Sampling |
| Operating Temperature | Ambient (15–30 °C) |
| Detection Range | ppb to ppm |
| Target Gases | Cl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDA-FR |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-FR |
| Detection Technologies | IMS, PID, MOS, EC |
| Sensor Channels | 8 independent parallel channels |
| Library Size | >300 calibrated chemical signatures |
| Response Time | <2 s (typical), ≤60 s (full quantification) |
| Detection Range | Sub-ppb to ppm level depending on analyte |
| Power | Rechargeable Li-ion battery, >8 h continuous operation |
| Compliance | CE, RoHS, ATEX Zone 2/22 (optional), IEC 61508 SIL2-ready architecture |
| Operating Temperature | −10 °C to +50 °C |
| Ingress Protection | IP65 |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Detection Principle | Hybrid IMS/PID/MOS/EC Sensor Fusion |
| Core Configuration | Multi-Channel VOC & Inorganic Gas Detector |
| Operating Temperature | −30 °C to 50 °C |
| Relative Humidity Range | 5–95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion Battery (30 W, 8 h runtime) |
| Weight | 4.2 kg |
| Sample Introduction | Integrated Auto-Sampling Pump with Continuous Gas Flow |
| Cycle Time | 5 min |
| Response Time | 2–60 s |
| Detection Library | >300 Pre-Calibrated Compounds (VOCs, Inorganic Gases, Electronic Specialty Gases), Expandable |
| Data Interfaces | RS-232, Ethernet, Wireless Transmission |
| Software | WinMuser GDA Suite |
| Heating Module | Integrated IR Heater for Solid/Surface Residue Volatilization |
| Alarm Logic | Template-Based Pattern Recognition with User-Configurable Thresholds |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-FR |
| Detection Principles | Ion Mobility Spectrometry (IMS), Photoionization Detection (PID), Metal Oxide Semiconductor (MOS), Electrochemical (EC) |
| Sensor Architecture | 8-channel parallel detection array |
| Response Time | <10 seconds for qualitative/quantitative identification |
| Target Analytes | 40+ industrial toxic gases and chemical warfare agents (CWAs) |
| Compliance | Designed for field deployment under ISO 17025-aligned operational protocols, compatible with GLP/GMP documentation workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-X |
| Pricing | Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | HT2000 |
| Sample Tray Capacity | 14-position or 42-position (selectable) |
| Heating Temperature Range | Off / 40–170 °C |
| Heating Time | Off / 0–999 min |
| Vibration Mode | Oscillatory agitation |
| Vibration Cycle | Off / 0–9.9 min |
| Sample Analysis Time | 0–60 min |
| Dimensions (H×W×D) | 696 × 330/350 × 320/520 mm (door open/closed |
| Power Supply | 100–240 V AC, 50–60 Hz, 1.6 A |
| Weight | 10 kg |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | IRS1200 |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | M-IR |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Imported |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Model | MI10 |
| Wavenumber Range | 500–5000 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Compliance | Designed for field-deployable chemical identification in accordance with ISO 17025-aligned operational workflows |
| Software | Embedded real-time spectral acquisition and library-matching interface |
| Data Handling | On-device storage with USB export and optional cloud-sync capability |
| Environmental Rating | IP54-rated enclosure for dust and splash resistance |
| Power Supply | Rechargeable Li-ion battery (≥4 h continuous operation) |
| Dimensions & Weight | 320 × 240 × 120 mm |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Mobile-IR |
| Design | Integrated ATR-based Portable FTIR System |
| Spectral Range | 4000–600 cm⁻¹ (typical) |
| Spectral Resolution | ≤4 cm⁻¹ (user-selectable) |
| Library | >14,000 reference spectra of hazardous, industrial, and environmental chemicals |
| Compliance | IP67-rated enclosure |
| Data Interface | Wi-Fi, USB, Bluetooth |
| Operating System | Embedded Linux with OPUS/Mentor software suite |
| Display | High-brightness capacitive touchscreen (≥10.1″) |
| Power | Rechargeable Li-ion battery (≥6 h continuous operation) |
| Weight | <5.2 kg |
| Dimensions | 320 × 240 × 180 mm (L×W×H) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Olfosense |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±1–2% |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 second |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC concentrations, user-selectable odorant(s) (1–2), and dimensionless odor unit (OU) values |
| Connectivity | WiFi/GSM/GPRS/3G |
| Data Integration | Open API, Modbus TCP/RTU, MQTT |
| Compliance | Designed for EN 13725-compliant odor assessment workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN 3.5 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | < 1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (integrated mass flow control) |
| Built-in Pumps | 2 (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD panel |
| Interface | USB and/or RS232 |
| Digital I/O | TTL and digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limits | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software Platform | WinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| Data Integrity | Audit-trail enabled |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Type | Olfactory Analysis System (Electronic Nose) |
| Sensor Technology | Metal Oxide Semiconductor (MOS) Array |
| Data Acquisition | Standalone Operation with Onboard LCD Display & Internal Data Storage |
| Sampling Modes | Manual, Automated Headspace, Adsorption-Desorption Gas Interface, Optional Pre-concentration Unit |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | <1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (internally regulated) |
| Sampling System | Dual built-in pumps (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD screen |
| Interface | USB and/or RS232 |
| Digital I/O | TTL & digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limit | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software | WinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| OS Compatibility | Windows XP and later |
| Calibration Stability | Automated drift compensation over 12 months |
| Warranty | 1 year |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Sensor Array | 10 MOS metal oxide sensors |
| Odor Unit Quantification | OU/m³ per EN 13725 |
| Data Logging | Integrated DCR computer (Mini-ITX, 40 GB HDD, 512 MB RAM, Windows XP) |
| Connectivity | Wi-Fi + optional GSM/GPRS module for SMS alerts |
| Meteorological Integration | Co-located anemometer and wind vane with real-time digital output |
| Compliance | EN 13725:2003 certified odor quantification methodology |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | meteo |
| Compliance | EN 13725 |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Sensor Array | 10 MOS (Metal Oxide Semiconductor) sensors |
| Data Acquisition | Continuous, 24/7 |
| Communication | Wi-Fi + optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer & wind vane |
| Software Algorithms | PCA, PLS regression, Mahalanobis & Euclidean distance analysis |
| Calibration Reference | EN 13725-compliant dynamic olfactometry |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Compliance | EN 13725:2003 |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array with Multivariate Pattern Recognition |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Data Transmission | Wi-Fi + Optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer and wind vane |
| Operating Mode | Fully Automated, Unattended 24/7 Monitoring |
| Software Algorithms | PCA, PLS, Mahalanobis Distance, Euclidean Distance |
| Sensor Configuration | 10-channel MOS sensor array |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3.5 |
| Instrument Type | Portable |
| Detection Principle | Multi-sensor array (Metal Oxide Semiconductor, Electrochemical, PID) |
| Sensor Array | 10 distinct MOS sensors |
| Software Platform | WinMuster v5.x |
| Data Analysis Algorithms | PCA, LDA, DFA, K-NN (Euclidean & Mahalanobis), PLS |
| Compliance | Designed for ISO 18562-3 (biocompatibility of gas pathways), ASTM E2147-22 (odor intensity measurement), GLP-compliant audit trail support |
| Operating Environment | 5–40 °C, 20–90% RH (non-condensing) |
| Sample Introduction | Integrated auto-sampling pump with mass-flow-controlled inlet (0.1–1.0 L/min adjustable) |
| Connectivity | USB 2.0, RS-232, optional Ethernet module for remote station integration |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Sampling Kit |
| Compliance | Designed to Support ASTM D6196, ISO 16017-1, USP <621>, EPA Method TO-17 & TO-15 Derivatives |
| Sample Matrices | Gaseous, Aerosol, Liquid (Aqueous/Organic), Solid (Soil/Sediment), Semi-solid, Biological, and Unknown Contaminants |
| Integrated Preparative Functions | Thermal Desorption, Liquid-Liquid Extraction, Headspace Equilibration, Solid-Phase Adsorption, Solvent Elution, Filtration, and Direct GC/MS Injection Compatibility |
| Accessories | Color-Coded PTFE-Sealed Vials, Tenax/Composite/Desorption Cartridges (Blue/Black/Red), Certified Deuterated Internal Standards (D6-Benzene, D8-Toluene, D10-Xylenes, D8-Naphthalene, D10-Anthracene, D10-Pyrene), Eppendorf Varipette 4720 (10 mL) & Biomaster 4830 (5 µL), Swagelok Alu-Plexiglas Fittings |
| Packaging | Ruggedized Portable Case with Modular Trays and Visual Identification System (Color-Coded by Matrix & Method) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Models | TS-5000Z (Electronic Tongue), PEN3 (Electronic Nose) |
| Application | Odor and Taste Profiling, Quality Control, Process Monitoring, Sensory Fingerprinting |
| Detection Principle | Multi-channel Biomimetic Lipid Membrane Sensors (TS-5000Z) |
| Sensitivity | Sub-ppb (PEN3), Quantitative Taste Index Resolution (TS-5000Z) |
| Compliance | Designed for GLP-compliant workflows |
| supports ASTM E2897-21 (Standard Guide for Electronic Nose Data Acquisition and Analysis) and ISO 22964 | 2021 (Electronic Tongues — Performance Requirements and Test Methods) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECOFOG |
| Pricing | Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | FOGBOOSTER |
| Quotation | Available Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | None |
| Operating Temperature | Ambient (Cold Fogging Only) |
| Disinfectant Type | Anhydrous Formulation (GD-6) |
| External Dimensions (L×W×D) | Not Specified |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Surf-Ex |
| Certification | ATEX Zone 1 & Zone 21 compliant |
| Decontamination Method | Spray-Extraction with Integrated Vacuum Recovery |
| Max Effective Coverage | 200 cm (80 in) |
| Max Hose Extension Length | 15 m |
| Collection Capacity | Compatible with standard 20–60 L containment drums |
| Pump Type | Explosion-proof diaphragm pump |
| Inlet Diameter | Large-diameter suction port for bulk particulate and sorbent material removal |
| Application Scope | Surface decon of sensitive equipment interiors, aircraft fuselages, ship compartments, infrastructure, and contaminated soil/sorbents |
| Compliance | Meets EU Directive 2014/34/EU (ATEX), IEC 60079-0/-10/-14, and supports GLP-aligned documentation workflows |