aixACCT
Filter
Showing all 8 results
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 1000 |
| Voltage Range | ±12 V (expandable to ±10 kV) |
| Frequency Range | 0.01 Hz – 1 kHz |
| Fatigue Test Frequency | up to 50 kHz |
| Minimum Pulse Width | 20 µs |
| Output Impedance | 50 Ω |
| Max Capacitive Load | 100 nF |
| Output Current | ±50 mA |
| Current Amplification Range | 1 nA – 1 A |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 1000 |
| Voltage Range | ±12 V (expandable to ±10 kV) |
| Frequency Range | 0.01 Hz – 1 kHz |
| Fatigue Test Frequency | up to 50 kHz |
| Minimum Pulse Width | 20 µs |
| Output Impedance | 50 Ω |
| Max Capacitive Load | 100 nF |
| Output Current | ±50 mA |
| Current Amplification Range | 1 nA – 1 A |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 2000E |
| Voltage Range | ±25 V (extendable to ±10 kV) |
| Hysteresis Frequency | 0.001 Hz – 5 kHz |
| Minimum Pulse Width | 2 µs |
| Minimum Rise Time | 1 µs |
| Current Measurement Range | 1 pA – 1 A |
| Maximum Load Capacitance | 1 µF |
| Peak Output Current | ±1 A |
| Module Options | FE (Ferroelectric), MR (Magnetoresistive), RX (Relaxation Current), DR (Dielectric Retention) |
| Channel Capacity | 256-channel automated testing |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 2000E |
| Voltage Range | ±25 V (extendable to ±10 kV) |
| Hysteresis Frequency | 0.001 Hz – 5 kHz |
| Minimum Pulse Width | 2 µs |
| Rise Time | ≤1 µs |
| Current Measurement Range | 1 pA – 1 A |
| Max Capacitive Load | 1 µF |
| Peak Output Current | ±1 A |
| Module Options | FE (Ferroelectric), MR (Magnetoresistive), RX (Relaxation Current), DR (Dielectric Retention) |
| Channel Count | 256-channel automated testing capability |
| Operating System | Windows 7 embedded |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 3000E |
| Voltage Range | ±25 V (extendable to ±10 kV) |
| Hysteresis Frequency | up to 1 MHz (High-Speed FE Module) |
| Minimum Pulse Width | 50 ns |
| Minimum Rise Time | 10 ns |
| Maximum Fatigue Frequency | 16 MHz |
| Current Amplification Range | 1 pA to 1 A |
| Max Load Capacitance | 1 nF |
| Peak Output Current | ±1 A |
| Software Platform | aixPlorer v5.x (Windows 7/10 compatible) |
| Compliance | ASTM D991, IEC 62047-18, ISO/IEC 17025-ready architecture |
| Modularity | FE, MR, RX, DR modules |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 3000E |
| Voltage Range | ±25 V (extendable to ±10 kV) |
| Hysteresis Frequency | up to 1 MHz (high-speed FE module) |
| Minimum Pulse Width | 50 ns |
| Minimum Rise Time | 10 ns |
| Fatigue Test Frequency | up to 16 MHz |
| Current Measurement Range | 1 pA – 1 A |
| Maximum Load Capacitance | 1 nF |
| Output Current Peak | ±1 A |
| Software Platform | aixPlorer v7.x (Windows 7-based) |
| Compliance | GLP/GMP-ready architecture, ASTM E2941-22 compatible, supports 21 CFR Part 11 audit trails (with optional software license) |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 3000E |
| Voltage Range | ±25 V (extendable to ±10 kV) |
| Dynamic Hysteresis Frequency | up to 1 MHz (High-Speed FE Module) |
| Minimum Pulse Width | 50 ns |
| Minimum Rise Time | 10 ns |
| Maximum Fatigue Frequency | 16 MHz |
| Current Amplification Range | 1 pA – 1 A |
| Max Capacitive Load | 1 nF |
| Output Current Peak | ±1 A |
| Software Platform | aixPlorer v7.x (Windows 7-based) |
| Compliance | ASTM D991, IEC 62047-18, ISO/IEC 17025-ready architecture |
| Channel Count | 256-channel automated testing capability |
| Brand | aixACCT |
|---|---|
| Origin | Germany |
| Model | TF Analyzer 3000E |
| Voltage Range | ±25 V (extendable to ±10 kV) |
| Hysteresis Frequency | up to 1 MHz (High-Speed FE Module) |
| Minimum Pulse Width | 50 ns |
| Minimum Rise Time | 10 ns |
| Maximum Fatigue Frequency | 16 MHz |
| Current Amplification Range | 1 pA to 1 A |
| Max Load Capacitance | 1 nF |
| Peak Output Current | ±1 A |
| Software Platform | aixPlorer v5.x (Windows 7/10 compatible) |
| Compliance | ASTM D991, IEC 62047-18, ISO/IEC 17025-ready architecture |
| Modularity | FE, MR, RX, DR modules |