ALISN
Filter
Showing 31–39 of 39 results
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-150 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Chamber Dimensions (W×H×D) | 600 × 620 × 405 mm |
| Internal Volume | 150 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | E+E Elektronik, Austria |
| Temperature Sensor | Heraeus, Germany |
| Insulation | Monolithic Polyurethane Foam |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | 3-year capacity (1-min intervals), exportable via USB, read-only |
| Audit Trail | 16,000+ immutable entries (operations & alarms), USB exportable |
| User Management | 5 configurable roles with hierarchical permissions |
| Communication Interfaces | RS232, RS485, USB-B |
| Compliance Support | GLP/GMP-ready logging, 21 CFR Part 11-compatible audit trail architecture |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-150S |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to +85 °C |
| Humidity Range | 10–98 %RH |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Uniformity | ±1.5 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Internal Dimensions (W×H×D) | 600 × 620 × 405 mm |
| Internal Volume | 150 L per compartment |
| Total Volume | 300 L |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 1500 W × 2 |
| Refrigeration Power | 250 W (R134a) |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | E+E Elektronik, Austria |
| Temperature Sensor | Heraeus, Germany |
| Insulation | Monolithic Polyurethane Foam (≥80 mm thickness) |
| Data Logging | ≥10 years of uneditable raw data storage |
| Audit Trail Capacity | 16,000 entries |
| User Management | 5 configurable roles with granular permissions |
| Communication Interfaces | RS232, RS485, USB |
| Display | 7-inch full-color capacitive touchscreen |
| Control Algorithm | PID + Fuzzy Logic hybrid control |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-250 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 15–98 % RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Interior Dimensions (W×H×D) | 670 × 912 × 410 mm |
| Interior Volume | 250 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | Capacitive, E+E Elektronik, Austria |
| Temperature Sensor | HERAEUS, Germany |
| Insulation | Monolithic Polyurethane Foam |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | ≥10 years (non-editable, USB export) |
| Audit Trail | 16,000 entries (user actions & alarms, non-editable, USB export) |
| User Management | 5 configurable roles with granular permissions |
| Communication Interfaces | RS232, RS485, USB |
| Language Support | English / Chinese Switchable |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Protections | Over-temperature, over-pressure, leakage current, low-water, door-open, sensor fault, auto-restart after power failure |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-460 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Uniformity | ±1.5 % RH |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 770 × 1200 × 500 mm |
| Compressor | Secop (Danfoss Group) |
| Condenser Fan | EBM-Papst |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Temperature Sensor | Heraeus platinum RTD |
| Insulation | Monolithic polyurethane foam |
| Power Supply | AC 220 V, 50/60 Hz |
| Data Logging | ≥10 years internal storage, USB export with write-protection |
| Audit Trail Capacity | 16,000 entries |
| User Management | 5 configurable roles with hierarchical permissions |
| Brand | ALISN |
|---|---|
| Model | THA760 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 15–98 % RH |
| Temperature Uniformity (at 15–45 °C) | ±0.3 °C |
| Temperature Fluctuation | ±0.3 °C |
| Humidity Uniformity | ±1.5 % RH |
| Humidity Fluctuation | ±1.5 % RH |
| Heating/cooling Rate | 1.0–3.0 °C/min |
| Internal Dimensions (W×H×D) | 1200 × 1180 × 540 mm |
| Internal Volume | 760 L |
| Refrigerant | R404a |
| Compressor | SECOP (Danfoss Group) |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Insulation | Monolithic polyurethane foam (≥100 mm thickness) |
| Control System | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touchscreen |
| Data Logging | 3-year storage (1-min interval), USB export, write-protected |
| Audit Trail | 16,000 entries (user actions & alarms), non-modifiable, USB-exportable |
| User Management | 5 configurable roles with granular permissions |
| Communication Ports | RS232, RS485, USB host/device |
| Compliance Support | ASTM E145, ISO 17025, ICH Q1, USP <1151>, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 1000 |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidity control) | −10 °C to 85 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Chamber Volume | 1000 L |
| Control Method | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | Internal non-volatile memory (≥10 years of continuous data), USB export with write-protected binary format |
| Audit Trail | 16,000 entries (user actions, alarms, system events), immutable export via USB |
| User Management | Up to 5 configurable accounts with role-based permissions |
| Sensor System | HERAEUS platinum RTD temperature sensors |
| Insulation | Monolithic polyurethane foam injection (≥120 mm thickness, thermal conductivity ≤0.022 W/m·K) |
| Airflow Design | Dual-side aerodynamic ventilation ports (Ø50 mm) |
| Door Structure | Double-door configuration with tempered inner glass door |
| Communication Interfaces | RS232, RS485, USB-B (for data export and EMS integration) |
| Power Supply | AC 220 V ±10 %, 50/60 Hz |
| Safety Protections | Over-temperature cutoff, refrigerant high-pressure shutdown, leak current protection, low-water alarm, door-open alert, sensor fault detection, auto-restart after power recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 460 |
| Refrigeration | Inverter-driven SECOP (Danfoss) compressor |
| Humidity Reservoir | External water tank |
| Temperature Range (dry) | −10 °C to 85 °C |
| Temperature Uniformity (15–45 °C) | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Chamber Volume | 460 L |
| Insulation | High-density polyurethane integral foaming |
| Cooling Refrigerant | R404a |
| Heating & Humidification Power | 2300 W |
| Compressor Power | 550 W |
| Sensor System | HERAEUS temperature sensor + E+E Electronics capacitive humidity sensor |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | ≥10 years internal storage, USB export (read-only, tamper-proof) |
| Audit Trail | 16,000+ immutable entries (user actions, alarms, system events) |
| User Management | 5 configurable roles with hierarchical permissions |
| Airflow Design | Dual-side aerodynamic 50 mm ports |
| Door Structure | Double-door, inner tempered glass viewing window |
| Communication Interfaces | USB, RS232, RS485 (EMS integration ready) |
| Compliance Support | GLP/GMP-aligned operation logs, 21 CFR Part 11–compatible data integrity architecture |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | TPC 760 |
| Refrigeration System | Inverter-driven SECOP (Danfoss) compressor with R404a refrigerant |
| Humidity Reservoir | External water tank |
| Temperature Range (with humidification) | −10 °C to 85 °C |
| Temperature Range (without humidification) | −10 °C to 85 °C |
| Temperature Uniformity (at 25 °C, empty chamber) | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Range | 10–98 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Chamber Volume | 760 L |
| Insulation | High-density polyurethane foam, one-shot foaming process |
| Airflow Design | Dual-side aerodynamic ventilation ports (Ø50 mm) |
| Viewing Window | Tempered glass inner door |
| Control System | 7-inch color TFT touch screen with PID + fuzzy logic algorithm |
| Data Logging | Internal non-volatile memory (≥10 years of continuous 1-min interval logging), USB export (read-only, tamper-proof), audit trail (16,000 entries), user permission management (5 configurable roles) |
| Compliance Support | GLP-compliant data integrity, 21 CFR Part 11-ready audit trail and electronic signature capability (via optional software module), ISO 17025 traceable calibration support |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | MTN-80 |
| Price | USD 2,500 (FOB Shanghai) |