All Precision Instrument
Filter
Showing 31–53 of 53 results
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-19+ |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤100 W |
| Max Operating Pressure | 9999 mbar |
| Min Inlet Pressure | 4000 mbar |
| Pressure Range for Testing | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Test Accuracy | ±4% |
| Test Duration (Bubble Point) | 15 ± 2 min |
| Test Duration (Enhanced Bubble Point) | 20 ± 2 min |
| Test Duration (Diffusion Flow) | 10 ± 2 min |
| Display | 5.7" monochrome TFT LCD |
| Interface | RS232 serial port |
| Data Storage | 500 test records (configurable extension via PC connection) |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Dimensions (W × D × H1 × H2) | 400 × 380 × 100 × 235 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BQS-40 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Maximum Operating Pressure | 7999 mbar |
| Inlet Gas Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant architecture, GMP-aligned audit trail |
| Enclosure Rating | IP54 |
| Supported Test Methods | Bubble Point, Diffusion Flow, Pressure Hold (Decay), Water Intrusion |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BRXZZ |
| Price | USD 3,500 (FOB Beijing) |
| Temperature Range | Ambient to 400 °C |
| Temperature Stability | ±0.1 °C |
| Temp. Recovery Time | < 4 min |
| Cut Count | 1–99 |
| Cut Interval | 10–600 s |
| Continuous Operation | >10,000 h |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Die Diameter | Φ2.095 ±0.005 mm |
| Die Length | 8.000 ±0.025 mm |
| Barrel ID | Φ9.550 ±0.025 mm |
| Barrel Length | 152.0 ±0.1 mm |
| Piston Head Diameter | 9.475 ±0.015 mm |
| Piston Head Length | 6.350 ±0.100 mm |
| Standard Loads (8 levels) | 0.325 kg (3.187 N) to 21.600 kg (211.82 N) |
| Brand | All Precision Instrument |
|---|---|
| Model | BU-800A |
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Power Supply | 220 V ±5%, 50 Hz, 2 kW |
| UV Lamp Configuration | 16 × 20 W low-pressure mercury lamps (253.7 nm peak output) |
| Conveyor Speed | 0–5 m/min (infinitely variable, digital display) |
| Tunnel Dimensions | 2000 mm (L) × 500 mm (W) × 200–300 mm (H, adjustable inlet/outlet height) |
| UV Exposure Zone | 1000 mm |
| Construction Material | 304 stainless steel (outer shell: 1.2 mm |
| inner reflective chamber | 1.0 mm mirror-finish #2B) |
| Conveyor Belt | Black PTFE-coated mesh belt |
| Safety Features | Light-shielded entry/exit zones with adjustable baffles, overvoltage/overcurrent protection, real-time lamp hour counter, fault alarm indication |
| Key | Brand: All Precision Instrument |
|---|---|
| Model | BWD-C |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | GB 1682, GB 5470–2008, HG 2-162–1965 |
| Temperature Range | Ambient to –70 °C (ambient ≤25 °C) |
| Temperature Stability | ±0.3 °C |
| Cooling Rate | ~2.5 °C/min (0 to –30 °C), ~2.5 °C/min (–30 to –40 °C), ~2.0 °C/min (–40 to –70 °C) |
| Internal Chamber Dimensions | 280 × 170 × 120 mm (L×W×H) |
| External Dimensions | 900 × 500 × 800 mm (L×W×H) |
| Sample Capacity | 1 test fixture (4 rubber or 15 plastic specimens per cycle) |
| Timer Range | 0–99 min, 1 s resolution |
| Impact Head Radius | 1.6 ± 0.1 mm |
| Impact Gap | 6.4 ± 0.3 mm |
| Centerline Offset | 8 ± 0.3 mm |
| Cooling Medium | Industrial ethanol or non-freezing liquid |
| Circulation Motor | 8 W |
| Power Supply | 220–240 V AC, 50 Hz, 1.5 kW |
| Operating Ambient | ≤25 °C |
| Cooling System | Compressor-based with proportional heating compensation |
| Stirring | Continuous circulation for thermal uniformity |
| Safety | Integrated over-temperature and low-coolant-level alarm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWD-D |
| Temperature Control Range | Ambient to –70 °C (ambient ≤25 °C) |
| Temperature Stability | ±0.3 °C |
| Cooling Rate | ~2.5 °C/min (0 °C to –30 °C) |
| Internal Chamber Dimensions | 280 × 170 × 120 mm (L×W×H) |
| External Dimensions | 900 × 500 × 800 mm (L×W×H) |
| Sample Capacity | 1 test fixture (4 rubber specimens or 15 plastic specimens per test cycle) |
| Timer Range | 0–99 min, 1-s resolution |
| Cooling Medium | Ethanol or other non-freezing liquid |
| Stirring Motor Power | 8 W |
| Power Supply | 220–240 V AC, 50 Hz, 1.5 kW |
| Operating Ambient Limit | ≤25 °C |
| Impact Head Radius | 1.6 ± 0.1 mm |
| Impact Gap (head to specimen holder) | 6.4 ± 0.3 mm |
| Horizontal Offset (impact centerline to holder centerline) | 8 ± 0.3 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electronic Tensile Testing Machine |
| Maximum Test Load | 6 kN |
| Force Measurement Range | 2–100% of Full Scale |
| Force Accuracy | ±1% FS |
| Test Stroke | 600 mm |
| Displacement Resolution | 0.01 mm |
| Speed Range | 0.05–500 mm/min |
| Speed Accuracy | ±1% |
| Compliance Standards | GB/T 16491, GB/T 1040, ASTM D412, ASTM D3759, ISO 37, ISO 34-1, EN ISO 1798, DIN 53507-A |
| Power Supply | AC 220 V ±10%, 50 Hz, 0.5 kW |
| Dimensions (W×D×H) | 400 × 400 × 1300 mm |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BWN-5-10KN |
| Max Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.4–100% of full scale |
| Force Resolution | 1/200,000 of full scale (fixed, no range switching) |
| Effective Test Width | 400 mm (customizable) |
| Effective Tensile Travel | 800 mm (customizable) |
| Test Speed Range | 50–300 mm/min |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Drive System | Servo Motor + Precision Ball Screw |
| Power Supply | 220 V / 380 V, 50 Hz |
| Power Consumption | 0.75 kW (typical) |
| Net Weight | ~300 kg |
| Compliance | GB/T 16491–2008, ASTM E4, ISO 7500-1, EN 10002-2 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | BWR-300 Series |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 120 ±5 °C/h or 50 ±3 °C/h |
| Temperature Resolution | 0.01 °C |
| Max. Temp. Accuracy | ±0.5 °C |
| Deformation Measurement | Digital Dial Gauge (Grating-Type) |
| Deformation Range | –0.1 to 5.0 mm |
| Deformation Accuracy | ±0.01 mm |
| Sample Stations | 3 independent test positions per bath |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt) |
| Heating Power | 2.5 kW |
| Cooling Method | Natural air cooling above 150 °C |
| Load Capacity | VST: 10 N ±0.2 N or 50 N ±1 N |
| HDT | configurable for ASTM D648 / ISO 75 stress levels (0.45, 1.80, or 8.00 MPa) |
| Span Options | 64 ±1 mm (flatwise) or 100 ±1 mm (edgewise) |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C-50KV |
| Max Output Voltage | 50 kV AC/DC (RMS) |
| Input Voltage | AC 220 V |
| Power Rating | 3 kVA |
| Voltage Ramp Rate | 0.1–5.0 kV/s (adjustable) |
| Compliance | GB/T 1981.2–2003, GB/T 7113.2–2005, GB/T 10580–2003, ISO 293, ISO 294-1, ISO 294-3, ISO 295, ISO 10724, IEC 60296, IEC 60455-2, IEC 60674-2 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDA-A |
| Price | USD 2,500 (approx.) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic |
| Model | HMQG-100 |
| Instrument Type | Metallographic Cutting System |
| Cutting Display Resolution | 0.01 mm |
| Dimensional Accuracy | ±1 mm |
| Internal Worktable Dimensions | 600 × 600 mm |
| X-Axis Travel Range | 1000 mm |
| Minimum Specimen Size | 25 × 25 × 5 mm |
| Maximum Specimen Thickness | 400 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.2 kW |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JF-5 |
| Oxygen Sensor Range | 0–100% O₂ |
| Resolution | ±0.1% |
| Accuracy Class | 0.1 |
| Flow Control Range | 0–20 L/min (0–1200 L/h) |
| Combustion Tube Internal Diameter Options | ≥75 mm or ≥85 mm |
| Gas Linear Velocity in Tube | 40 ± 2 mm/s |
| Input Pressure | 0.25–0.3 MPa |
| Operating Pressure (N₂/O₂) | 0.15–0.20 MPa |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | 150 W |
| Ambient Temp | Room Temp to 40 °C |
| Relative Humidity | ≤70% |
| Ignition Flame Length | 16 ± 4 mm (adjustable 5–60 mm) |
| Compliance Standard | GB/T 2406.2–2009 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | S-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet for PC connectivity and remote supervision |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11 (audit trail ready), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WYZ-240 |
| Price | USD 2,800 (FOB Beijing) |
| Max Cutting Width | 300 mm |
| Max Cutting Thickness | 15 mm |
| Max Milling Length (Flat/Dumbbell) | 300 mm |
| Cutting Wheel Dimensions | 200 × 32 × 2 mm |
| Notch Milling Tool Length | 50 mm |
| Dumbbell/Flat Milling Tool Dimensions | 30 × 12 × 30 mm |
| Overall Dimensions | 1130 × 720 × 950 mm |
| Spindle Speeds | Cutting Section: 1400–2800 rpm |
| Notch Milling Section | 400 rpm |
| Dumbbell/Flat Milling Section | Low-Speed: 470 / 940 rpm |
| High-Speed | 715 / 1430 rpm |
| Motor Power | Notch Milling Motor: 550 W |
| Dumbbell/Flat Milling Motor | 0.8–1.3 kW |
| Cutting Motor | 0.8 kW |
| Cooling Oil Pump Motor | 60 W |
| Auto-Feed Motor (Flat/Dumbbell) | 60 W |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Scale Offline TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% RSD |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Operating Temperature | 10–40 °C (±5 °C/day max) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS |
| Span Drift | ±5% FS |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 100 W |
| Dimensions | 44 × 18 × 26 cm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Model | HMYS-200 |
| Temperature Range | RT–200 °C |
| Chamber Volume (W×D×H) | 350×300×300 mm |
| External Dimensions | 600×420×450 mm |
| Temperature Uniformity | ±1% of full scale |
| Timer Range | 1–9999 min |
| Compression Ratios | 50%, 75%, 90% |
| Test Duration | 22 h |
| Specimen Size | 50×50×25 mm (5 pcs) |
| Glass Plate Thickness | 1.0–1.5 mm |
| Rated Voltage | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BSQ-20 |
| Power Supply | AC 220 V |
| Sample Vial Capacity | 12 mL |
| Vial Tray Configuration | 14 × 14 (196 positions) |
| Positioning Accuracy | ±0.01 mm |
| Controller Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| Frame Material | Anodized Aluminum Alloy |
| Motion Control | Digital Stepper Motor with Microstepping Driver |
| Automation Level | Fully Unattended Operation |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8005 |
| Pricing | Upon Request |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | B121 |
| Price | USD 1,200 (FOB Beijing) |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Measurement Principle | Guarded Three-Electrode Ring Method |
| Resistance Range | 1.0×10³ – 2.0×10¹² Ω |
| Resistivity Range | 1.0×10³ – 2.0×10¹² Ω·m |
| Sheet Resistance Range | 1.0×10⁴ – 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ – 0.1×10¹² Ω (auto-ranging) |
| Power Supply | 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 × 90 × 275 mm |
| Net Weight | ≤3.0 kg |
| Standard Electrode | Triple-ring coaxial electrode (center cylinder Ø50 mm × 40 mm h |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDJC-50kV |
| Maximum Output Voltage | 50 kV AC/DC |
| Output Current | Adjustable up to 100 mA (standard setting: 30 mA) |
| Voltage Accuracy | ≤ ±1% |
| Rising Rate Range | 10–3000 V/s (adjustable in 7 steps) |
| Power Input | AC 220 V, 3 kVA |
| Electrode Configurations | Two φ25 mm brass electrodes + One φ75 mm brass electrode |
| Test Environments | Air or transformer oil immersion |
| Compliance | Designed per IEC 60243-1, ASTM D149, GB/T 1408.1, and ISO 60243-1 |
| Safety Enclosure | Transparent acrylic shield |
| Dimensions (L×W×H) | 700 × 800 × 1500 mm |
| Weight | ~120 kg |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWR |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Heating Power | 2.5 kW |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt, 20 L required) |
| Sample Stands | Three independent test stations per bath |
| Deformation Measurement | Linear encoder-based dial indicator (resolution 0.001 mm, accuracy ±0.01 mm) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rates | 120 ±5 °C/h (12 ±1 °C/6 min) or 50 ±3 °C/h (5 ±0.5 °C/6 min) |
| Deformation Range | −0.1 to 5.0 mm |
| Cooling Method | Natural convection above 150 °C |
| Maximum Settable Temperature | 300 °C with over-temperature cut-off |
| Load Rod + Indenter Mass | 88 g |
| Standard Loads | Vicat GA = 10.0 N ±0.2 N (1000 g), GB = 50.0 N ±1.0 N (5000 g) |
| HDT fiber stress options | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) |
| Compliance | ASTM D1525, ASTM D648, ISO 306:2004, ISO 75-1:2013, GB/T 1633–2000, GB/T 1634.1–2004, GB 8802 |
| [Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSQ-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar (customizable sensor) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1,000,000 test records) |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Compliance | Fully supports GMP documentation requirements, audit trail-ready configuration, user-level access control (Operator/Supervisor/Admin), 21 CFR Part 11–compatible data handling with electronic signature support] |