Alpao
Filter
Showing all 10 results
| Brand | ALPAO |
|---|---|
| Aperture | 240 mm |
| Actuation Principle | Electromagnetic |
| Surface Type | Continuous Membrane (Silicon) |
| Wavefront Stroke | > 40 µm PV (typ.) |
| Response Time | < 300 µs (full stroke) |
| Linearity | > 98% |
| Operating Wavelength Range | 250–1100 nm |
| Compliance | ISO 9001 certified manufacturing |
| Mounting Interface | Customizable kinematic flange (CF-200 or CF-250 compatible) |
| Environmental Rating | Cleanroom-compatible, vacuum-compatible (optional) |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | ACE |
| Core Architecture | Modular GUI (Windows) & Deterministic Linux Real-Time Kernel (ACE Fast) |
| Feedback Bandwidth | Up to 1.2 kHz (ACE) / 5 kHz (ACE Fast) |
| Loop Latency | ~1.5 ms (ACE) / <150 µs (ACE Fast) |
| Operating System | Windows 10/11 (ACE), Real-Time Linux (ACE Fast) |
| Compliance | Compatible with ALPAO DMs (e.g., DM97-08, DM241, DM468), supports HDF5 data logging, IEEE 1588 PTP time synchronization ready |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | AOS-0 |
| Deformable Mirror Options | DM69 (69 actuators, 10.5 mm pupil) or DM97-15 (97 actuators, 13.5 mm pupil) |
| Wavefront Sensor Options | HASO4 First (VIS, 32×40 res., λ/100 RMS acc., 400–1100 nm) or WFS-VIS (23×23 res., λ/20 RMS acc., 250–1100 nm) |
| Max Closed-Loop Bandwidth | 800 Hz |
| Min Settling Time | 800 µs |
| Mirror Surface Flatness (Closed Loop) | ≤7.0 nm RMS |
| Tip/Tilt Stroke (PV, wavefront) | ≥60 µm |
| Focus/Astigmatism Stroke (PV, wavefront) | ≥40 µm |
| Operating Temperature | −10 to +35 °C |
| Coating | Protected Silver |
| Wavefront Sensor Interface | USB 3.0 or Camera Link |
| Imaging Monitor Camera | IDS UI-3240 (1280×1024, 60 fps, 10-bit, 60 dB DR) |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | DM Series |
| Actuation Principle | Magnetic Actuator |
| Maximum Wavefront Stroke | >80 µm (peak-to-valley) |
| Spatial Resolution | <5 µm |
| Response Time | <500 µs ±10% |
| Linearity Error | <7 nm RMS |
| Hysteresis | Negligible (typ. <0.5% F.S.) |
| Surface Quality | λ/20 @ 633 nm (rms) |
| Coating | Protected Aluminum (Ravg >92% from 400–1000 nm) |
| Operating Temperature | 15–30 °C |
| Interface | Analog ±10 V input per actuator |
| Compatibility | Compatible with real-time control systems (e.g., LabVIEW, MATLAB, Python via SDK) |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | DM Series |
| Actuator Count | 69–820 |
| Pupil Diameter | 7.2–45.0 mm |
| Max Wavefront Stroke (PtV) | 80–120 µm |
| Settling Time | 500–1600 µs |
| Bandwidth (−3 dB) | 400–2000 Hz |
| Hysteresis Error | <2% |
| Nonlinearity Error | <3% |
| Coating | Protected Silver (R > 96.5% @ 0.5–2.0 µm) |
| Operating Temperature | −10 to 35 °C |
| Drive Voltage | ±1 V |
| Power Consumption | <10 W |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | DMM Series |
| Surface Roughness (RMS) | <15 Å |
| Max. Stroke per Mode | ±100 µm |
| Coating | Protected Silver |
| LIDT (1064 nm, 12 ns, 10 Hz) | 880 mJ/cm² |
| LIDT (CW, 1064 nm) | 50 W |
| Control Interface | Ethernet (Web-based API) / USB (via dongle) |
| Zernike Mode Support | Yes |
| Enclosure | Standard Cylindrical Mount |
| Brand | Alpao |
|---|---|
| Origin | France |
| Type | OEM Deformable Mirror |
| Diameter | 50 mm |
| Max. Piston Stroke | 100 µm (P-V) |
| Fitting Error | ≤2% RMS |
| Actuation Principle | Electromagnetic |
| Control Mode | Zernike Mode-Based Open-Loop or Closed-Loop |
| Compatibility | Windows/Linux/macOS, C/C++/Python/MATLAB APIs |
| Power Supply | Low-Voltage DC (<24 V), Low Power Consumption |
| Sensor Integration | Compatible with Shack-Hartmann and Pyramid Wavefront Sensors |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | SH-CMOS |
| Spectral Range | 350–1700 nm |
| Subaperture Count | 50 × 50 |
| Microlens Pitch | 96.6 µm |
| Pupil Diameter | 4.83 µm |
| Sampling Frequency | 477 Hz (standard), up to 28.14 kHz (SH-CMOS Fast) |
| Readout Latency | 5000 µs (standard), down to 10.7 µs (SH-CMOS Fast) |
| Tilt & Defocus Range (PV) | ±96 µm / ±242 µm |
| Repeatability | <152 nm RMS |
| Compliance | Fully compatible with Alpao deformable mirrors and real-time control software |
| Brand | Alpao |
|---|---|
| Origin | Beijing, China (Distributed) |
| Model | WFS-SWIR |
| Spectral Range | 0.9–1.7 µm |
| Sensor Type | InGaAs |
| Max Acquisition Frequency | 3 kHz |
| Microlens Array | up to 23×23 |
| Microlens Pitch | 167–264 µm |
| Quantum Efficiency | >90% @ 600 nm, >70% @ 1500 nm |
| Dynamic Range (Tip-Tilt/Focus, PtV) | 10–15 µm |
| Residual WFE Error (Closed-Loop) | 20 nm RMS |
| Absolute Precision | λ/20 RMS |
| Repeatability | 10 nm RMS |
| Typical Read Noise | <150 e⁻ (high gain), <700 e⁻ (low gain) |
| Operating Temperature | 0–30 °C |
| Interface | Camera Link |
| Recommended Deformable Mirror Compatibility | DM69 / DM97 / DM277 / DM468 |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | WFS-VIS |
| Sensor Type | EMCCD |
| Spectral Range | 250–1100 nm |
| Max Acquisition Frequency | 1838 Hz (WFS-VIS-69) |
| Microlens Array | 8×8 to 23×23 |
| Microlens Pitch | 133–307 µm |
| Quantum Efficiency | >90% @ 600 nm |
| Dynamic Range (Tip-Tilt/Focus, PtV) | 10–20 µm |
| Residual WFE Error (Closed-Loop) | 20 nm RMS |
| Absolute Precision | λ/20 RMS |
| Repeatability | 10 nm RMS |
| Typical Noise | <0.1 electron RMS |
| Operating Temperature | 0–30 °C |
| Interface | Camera Link |
| Compatible Deformable Mirrors | DM69, DM97-15, DM277, DM468 |