| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C (optional low-temp module: –130°C to 1200°C) |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC |
| Gas Handling | Built-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator) |
| Sample Configuration | Removable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure) |
| Safety Systems | Multi-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility |
| Sample Capacity | 0.1–1.0 g |
| Sample Tube Types | Quartz U-tube, bubble tube, straight-wall tube (low-pressure) |
| Tubing | 1/16″ OD 316 SS, heated throughout |
| Gas Mixing | Internal precision gas mixer (no external mixer required) |
| Cooling | Automated air-cooling module |
| Safety Systems | Dual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 TPD/TPO/TPR Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300Neo Basic Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AMI-400 Automated Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |