AMS
Filter
Showing all 17 results
| Brand | AMS |
|---|---|
| Origin | USA |
| Model | 209.57 |
| Core Components | Stainless Steel |
| Connection Thread | 5/8" Unified National Fine (UNF) |
| Auger Diameter | 5.72 cm |
| Handle Length | 45.72 cm |
| Split-Core Sampler Diameter × Length | 3.49 cm × 15.24 cm |
| Extension Rod Length | 1.2 m |
| Plastic Liner Diameter × Length | 3.49 cm × 15.24 cm |
| Wrench Length | 30.48 cm |
| Stainless Steel Brush Diameter × Length | 3.81 cm × 30.48 cm |
| Standard Configuration | 1× General-Purpose Auger, 1× Sand Auger, 1× Clay Auger, 1× Rubber-Coated Handle, 1× Split-Core Sampler, 1× Standard Sliding Hammer, 3× Extension Rods, 1× Plastic Liner, 2× Plastic Caps, 2× Fixed-Size Wrenches, 1× Adjustable Wrench, 1× Stainless Steel Brush, 1× Premium Carrying Case |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS Flue Gas Heavy Metal Sampler |
| Instrument Type | Particulate and Heavy Metal Sampling System |
| Target Analytes | Heavy Metals (e.g., Pb, Cd, Hg, As, Ni, Cr) |
| Flow Accuracy | ±2% |
| Compliance Standard | UNI-EN 14385 |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS Flue Gas Particulate Sampling System |
| Instrument Type | Isokinetic Particulate Sampler |
| Flow Accuracy | ±2% |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS1 |
| Pricing | Upon Request |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS2 |
| Pricing | Upon Request |
| Construction Material | Stainless Steel |
| Sampling Depth | Up to 3.65 m |
| Kit Components | Main Sampling Probe, Internal Liner Tube, Handle, Adapter, Extension Rod |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS3 |
| Quotation | Upon Request |
| Sampling Capacity | 0.5 L |
| Standard Sampling Depth | 7.62 m (extendable) |
| Minimum Well Casing ID | 5.08 cm |
| Body Material | Stainless Steel |
| Sample Tube Material | Fluoropolymer |
| Valve Material | Fluoropolymer |
| Overflow Cap Material | Fluoropolymer |
| Included Components | Measured cable, cable controller, T-handle actuator, cable control accessories, fluoropolymer sample tube, fluoropolymer-valved top cap, overflow cap, two fluoropolymer tube caps |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Dioxin |
| Instrument Type | Flue Gas Dioxin Sampling System |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 1948:2006 |
| Sampling Methods | Filter-Condensation, Dilution, Cooled Probe |
| Primary Adsorbent | XAD-2 Resin or PUF Foam |
| Heating Zone Temperature | <125 °C (maintained above gas dew point) |
| Condenser Outlet Temperature | <20 °C |
| Main Flow Rate | 3–5 m³/h |
| Side Stream Flow Rate | 0.5–0.7 m³/h |
| Side-to-Main Flow Ratio Tolerance | ±10% |
| Linear Velocity in XAD-2 Tube | ≤34 cm/s |
| Brand | AMS |
|---|---|
| Origin | USA |
| Model | AMS 209.55 / 209.56 / 209.57 / 209.58 |
| Connection Thread | 5/8" UNC |
| Core Diameter Options | 5.72 cm (2.25") or 8.26 cm (3.25") |
| Handle Length | 45.72 cm (18") |
| Split-Sample Auger Dimensions | 3.49 cm × 15.24 cm or 5.08 cm × 15.24 cm |
| Rod Length | 1.2 m (4 ft) per section |
| Plastic Liner ID | 3.49 cm or 5.08 cm × 15.24 cm |
| Wrench Length | 30.48 cm (12") |
| Stainless Steel Brush Diameter | 3.81 cm or 5.08 cm × 30.48 cm |
| Standard Configuration Includes | 3 soil-specific augers (general, sand, clay), rubber-coated T-handle, split-sampling auger, slide hammer, 3 extension rods, 1 liner (25 liners in 209.58), 2 plastic caps (50 caps in 209.58), 2 fixed wrenches, 1 adjustable wrench, 1 stainless steel brush, fluoropolymer film (50 sheets in 209.56/209.58), #2 stainless steel trowel (209.56/209.58), heavy-duty portable case |
| Brand | AMS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FUTURA Segmented Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 240–720 positions |
| Reagent Positions | 5–30 |
| Flow Cell Path Length | 5–500 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GP |
| Price | USD 7,000 (FOB) |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GVP |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0–2 L/min |
| Operating Pressure | Ambient Atmospheric Pressure |
| Flow Stability | <2% over 1 h |
| Flowmeter Accuracy | ±2% FS |
| Service Life at Max Flow & Backpressure | >1000 h |
| Continuous Run Time at Max Flow & Backpressure | >2 h |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS HCl Flue Gas Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Flow Accuracy | ±2% |
| Compliance | EN 1911, ISO 9096:1992 |
| Operating Probe Temperature | ≥120 °C (≥20 °C above HCl acid dew point) |
| Filter Efficiency | >99.5% (glass fiber or quartz fiber) |
| Sample Transit Time | <5 s (nozzle to impinger) |
| Main Stream Flow Rate | 30–150 L/min (isokinetic mode) |
| Impinger Flow Rate | 2–3 L/min |
| Typical Sampling Volume | 50–200 L (for [HCl] = 1–10 mg/m³ |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Mercury Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Target Analyte | Mercury (Hg) and Other Heavy Metals |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 13211 |
| Sample Path Material | Borosilicate Glass & Inert Heated Components |
| Probe Operating Temperature | ≥120 °C (≥20 °C above acid dew point) |
| Max. Sample Residence Time | <5 s (from probe inlet to impinger train) |
| Brand | AMS |
|---|---|
| Origin | Germany |
| Model | RHADOX 7100 |
| Explosion Protection | ATEX II 2G Ex pxb IIB+H2 T4 Gb X (Zone 1) / ATEX II 3G IIB+H2 T3 Gc (Zone 2) |
| Response Time (T90) | 10–30 s |
| Repeatability | ≤1.0% of measured value |
| Long-term Drift | ≤2% of full scale per month |
| Temperature Drift | <0.02% / K (relative to span end) |
| Air Demand Range | 1.5–30 m³ air/m³ gas |
| Wobbe Index Range | 5–120 MJ/m³ |
| Analog Output | 2 × 4–20 mA (galvanically isolated) |
| Display | 2×16-character backlit LCD + optional full-color status display |
| Operating Temperature | –5°C to +45°C (electronics), +5°C to +60°C (gas path) |
| Gas Inlet/Outlet | 6/12 mm stainless steel tubing or flanged connections |
| Sample Flow Rate | 20–100 Nl/h (process gas), 50–500 Nl/h (instrument air) |
| Gas Pressure | ≥0.1 bar(g), max 17 bar(g) |
| Instrument Air | ≥2 bar(g), max 8 bar(g) |
| Power Supply | 115/230 V AC, 50–60 Hz, 500 VA |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 1000×900×350 mm |
| Weight | ~100–125 kg (configurable) |
| Brand | AMS |
|---|---|
| Origin | Germany |
| Model | RHADOX 7100/7100EX/7300/7300EX |
| Repeatability | CARI & Wi ≤ 1.0% of reading |
| Drift | ≤ 2% of reading/month |
| Response Time (T90) | 10–30 s (gas viscosity-dependent) |
| Explosion Protection | ATEX II 2G Ex pxb IIB+H2 T4 Gb X (Zone 1) |
| Operating Temperature | +5 °C to +60 °C |
| Sample Flow Rate | 20–100 NL/h (gas), 50–500 NL/h (instrument air) |
| Gas Inlet Pressure | ≥ 0.1 bar(g) (7100 series), ≥ 0.5 bar(g) (7300 series), max 17 bar(g) |
| Instrument Air Pressure | ≥ 2 bar(g), max 8 bar(g) |
| Analog Outputs | 2 × 4–20 mA (7100), 4 × 4–20 mA (7300), galvanically isolated |
| Digital Interface | RS232 (standard), optional RS485 or Ethernet |
| Measurement Parameters | Wobbe Index (Wi), Combustion Air Requirement Index (CARI), Specific Gravity (SG), Lower Calorific Value (LCV) |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Brand | AMS |
|---|---|
| Origin | Beijing, China |
| Model | NexaFlo™ |
| Configuration | Up to 14 independent analytical channels |
| Detection Principles | Continuous Flow Analysis (CFA) with segmented flow, online pre-treatment (dialysis, UV digestion, distillation, heating, dilution, mixing, extraction) |
| Detector Options | UV-Vis spectrophotometer, flame photometer (for K⁺/Na⁺), fluorimeter |
| Display | 7-inch color touchscreen (NexaFlo™ 450 variant) |
| Automation | Fully programmable CFA software with auto-startup/shutdown, QC control, auto-dilution, LIMS export, and audit-trail-capable operation |
| Compliance | Designed to support ASTM D129, ISO 11905-1, USP <621>, EPA Methods 353.2, 354.1, 365.2, and GLP/GMP-aligned data integrity practices |
| Sample Handling | Dual-probe autosampler optional |
| Fluidics | High-precision three-speed peristaltic pumps |
| Reagent Management | Integrated sealed reagent reservoirs with vapor/leak mitigation |