| Brand | AMS Alliance |
|---|---|
| Model | FUTURA |
| Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | ≥100 |
| Flow Cell Path Length | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Analysis Rate | 15–120 samples/hour |
| Sample Volume | 0.5–100 µL |
| Peristaltic Pump | 13 rollers per channel |
| Flow Rate Range | 50–3000 µL/min |
| Linear Absorbance Range | 0–2.5 AU |
| Dimensions | 240 × 650 × 410 mm |
| Weight | 17 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | 1–20 |
| Flow Cell Pathlength | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | FUTURA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 200 positions / 5 racks |
| Reagent Positions | 104 or 360 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Futura |
| Pricing | Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | iCinac |
| Channel Capacity | 16 or 32 simultaneous channels |
| Measurement Parameters | pH, Temperature (°C), Redox Potential (mV) |
| Power Supply | 110–220 V AC ±15%, 50–60 Hz |
| Dimensions | 510 × 450 × 300 mm (L × W × H) |
| Weight | 11–13 kg |
| Sensor Interface | Digital ISM-compatible multiparameter electrodes (pH/T/Redox) with embedded calibration memory |
| Data Output | 32 configurable outputs (digital + dual analog: 0–10 V / 4–20 mA) |
| Software | iCINAC v5.x with real-time compensation, audit trail, and GLP-compliant data logging |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 104-position turntable autosampler (optional 360-position XYZ autosampler) |
| Reagent Positions | 36 |
| Flow Cell Path Length | 50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Detection Limit | Sub-ppb level |
| Throughput | Up to 120 samples/hour |
| Pump Tubing | 52 channels (2 × 26) |
| Flow Rate Range | 50–3000 µL/min |
| A/D Resolution | 24-bit (1.68 × 10⁷) |
| Dimensions (Main Unit) | 75 × 50 × 42 cm |
| Weight (Main Unit) | 45 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMAs |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume | 0.5 mL |
| Reagent Positions | 104 |
| Flow Cell Path Length | 5–50 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | SmartChem 200 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Test | 300 µL |
| Sample Positions | 126 |
| Reagent Positions | 200 (including refrigerated slots) |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Tungsten Lamp (6 V / 10 W, 2000 h lifetime) |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions (standard configuration) |
| Reagent Positions | 72 (with optional refrigeration) |
| Wavelength Range | 340–880 nm |
| Cuvette Path Length | 6 mm |
| Light Source | 6 V / 10 W halogen lamp |
| Throughput | up to 450 determinations per hour (including ISE module) |
| Absorbance Range | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Temperature Control | 37 °C ± 0.3 °C |
| Dimensions | 500 × 700 × 1050 mm (H × W × L) |
| Weight | 48 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem 450 |
| Sample Throughput | Up to 450 samples/hour (colorimetric), 150 samples/hour (ISE) |
| Reaction Temperature Range | 30–50 °C (adjustable, ±0.1 °C accuracy) |
| Optical System | Dual-beam, dual-wavelength photometer with 12 filters (340–880 nm), 10 mm pathlength cuvettes |
| Absorbance Linearity | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 180 μL |
| Sample Capacity | 100 positions (5 rotating racks) |
| Reagent Capacity | 72 positions (refrigerated at 10 °C) |
| Dispensing Precision | 0.1 μL (1.0–900 μL sample |
| Dilution Ratio | Up to 100× |
| Cuvette Disk | 80 reusable quartz/glass cuvettes |
| Compliance | US EPA Method 353.2 (with Cd-column module), ISO/IEC 17025-compatible operation |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 600 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Pathlength | 6 or 10 mm |
| Light Source | LED |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem 600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Cup | 300 µL |
| Sample Capacity | 126 positions |
| Reagent Positions | 600 |
| Cuvette Path Length | 10 mm |
| Light Source | LED and Halogen Lamp |
| [Brand | AMS Alliance |
|---|---|
| Origin | USA |
| Model | Smartchem 600 |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 (with refrigeration) |
| Wavelength Range | 340–1100 nm |
| Cuvette Path Length | 10 mm (6 mm optional) |
| Detection Principle | Dual-beam, dual-wavelength photometry |
| Maximum Throughput | 600 samples/hour |
| Reaction Disc Capacity | 85 reusable cuvettes |
| Temperature Control | 37 °C ± 0.3 °C |
| Linear Absorbance Range | 0.00001–4.2 Abs |
| Resolution | 0.00001 Abs |
| Minimum Reaction Volume | 180 µL |
| Compliance | ISO, AOAC, US EPA, AFNOR, COFRAC, BATF] |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem140 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 330–840 nm |
| Sample Capacity | 64 positions |
| Reagent Positions | 24 + 10 |
| Cuvette Path Length | 6 mm |
| Light Source | Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem200 |
| Product Type | Automated Discrete Analyzer |
| Wavelength Range | 420–880 nm |
| Sample Capacity | 126 positions |
| Reagent Positions | 10 (expandable to 28) |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Tungsten Lamp (2000 h lifetime) |
| Measurement Speed | Up to 200 tests/hour (per method) |
| Minimum Reaction Volume | 300 µL |
| Absorbance Range | 0.001–2.500 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Thermostat Accuracy | 37 °C ± 0.3 °C |
| Dimensions (H×W×L) | 420 × 650 × 1000 mm |
| Weight | 43 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 12 fixed wavelengths from 340 to 880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Path Length | 6 mm or 10 mm |
| Light Source | High-stability LED |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | CINAC |
| Automation | Fully Automatic |
| Analysis Speed | 16 samples/min |
| Measurable Parameters | Temperature, pH, Redox Potential |
| Repeatability | <0.5% CV |
| Accuracy | <1.0% |
| Input Voltage | 110–220 V AC ±15%, 50–60 Hz |
| Dimensions (L×W×H) | 35 × 26 × 15 cm |
| Weight | 3.5 kg |
| Channel Configuration | Up to 16 pH electrodes (CINAC16), or mixed configurations (e.g., CINAC12: 12 pH + 4 Pt100 |
| CINAC14 | 14 pH + 2 Pt100) |
| Data Acquisition | Real-time logging of pH, temperature, and redox across 1–16 (expandable to 32 via dual-unit PC integration) channels |
| Calibration Traceability | Factory-calibrated against certified reference standards |
| Compliance | Designed in collaboration with INRA-LGMPA (France) |