Anasazi
Filter
Showing all 7 results
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2874, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11 (software-enabled audit trail) |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 |
| Operating Frequency | 60 MHz |
| Magnet Type | AlNiCo Permanent Magnet |
| Sample Form | Solid and Liquid (with appropriate probes) |
| Resolution (1H) | < 0.5 Hz |
| Sensitivity (1H) | < 0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si |
| Cryogen-Free Operation | Yes |
| Compliance | ASTM E2821, ISO/IEC 17025 (when operated under GLP conditions), FDA 21 CFR Part 11–ready software architecture |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60 / EFT-90 |
| Instrument Type | Benchtop High-Field NMR Spectrometer |
| Operating Frequency | 60 MHz / 90 MHz (¹H) |
| Sample Type | Liquid Solutions |
| Resolution | < 0.5 Hz (full width at half maximum, FWHM, for 1% ethylbenzene in CDCl₃) |
| Sensitivity | ≤ 0.001 mmol/L (for ¹H, single-scan, standard 5 mm tube) |
| Magnet System | AlNiCo permanent magnet with active temperature stabilization |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Software Platform | EFT-NMR v5.x with pulse sequence library and GLP-compliant audit trail |
| Compliance | Designed to support ISO/IEC 17025, ASTM E2823, and USP <724> method validation workflows |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| ¹H Resolution | < 0.5 Hz |
| Sensitivity | < 0.001 mmol/L (for ¹H, standard sample) |
| Supported Nuclei | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/low-γ nuclei |
| Software Platform | EFT-NMR Console v4.x |
| Compliance | ASTM E2857, ISO/IEC 17025 (method validation support), GLP-ready audit trail logging |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-60, EFT-90 |
| Operating Frequency | 60 MHz / 90 MHz |
| Sample Type | Liquid |
| Measurement Principle | Pulsed Fourier Transform NMR |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution (1H) | <0.5 Hz |
| Sensitivity | <0.001 mmol/L |
| Nuclei Supported | ¹H, ¹³C, ¹⁹F, ³¹P, ²³Na, ⁵⁹Co, ²⁹Si, and other quadrupolar/nuclear spin-½ nuclei |
| Compliance | ASTM E2874, ISO/IEC 17025-compatible operation, GLP-ready data audit trail |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (Broadband) |
| Magnet Type | AlNiCo Permanent Magnet |
| Resolution | < 0.5 Hz (at 90 MHz, 1H, in DMSO-d6) |
| Sensitivity | < 0.001 mmol/L (for 1H, typical small-molecule sample) |
| Cryogen-Free Operation | Yes (No Liquid Helium or Liquid Nitrogen Required) |
| Compliance | ASTM E2831-18 (Standard Guide for NMR Spectroscopy Data Reporting), ISO/IEC 17025:2017 (for lab accreditation readiness), GLP/GMP-compatible data audit trail via software |
| Brand | Anasazi |
|---|---|
| Origin | USA |
| Model | EFT-90 |
| Operating Frequency | 90 MHz |
| Sample Type | Solid & Liquid (with appropriate probes) |
| Magnet Type | AlNiCo permanent magnet |
| Resolution | < 0.5 Hz (for 1H at 90 MHz) |
| Sensitivity | < 0.001 mmol/L (for 1H) |
| Cooling | Zero-boil-off, helium-free operation |
| Compliance | Designed for GLP-compliant academic and industrial R&D environments |
| Software | EFT-NMR v5.x with full pulse sequence library and audit trail capability |