Anseros
Filter
Showing all 8 results
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6010T |
| Temperature Range | 26–60 °C (standard), 15–70 °C (extended) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Measurement Range | 0–100 / 1,000 / 10,000 pphm |
| Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±0.2 % of reading (ozone sensor) |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Recovery Time to 95 % Set Ozone Level | ≤10 min |
| Recovery Rate | 0.4 K/min |
| Temperature Compensation | Automatic, 0–60 °C ±1 °C |
| Pressure Compensation | Automatic, 600–1500 mbar ±2 mbar |
| Zero Drift | Auto-zeroing cycle every 2 s |
| Span Drift | None (single-beam optical design) |
| Power Supply | 230 V / 50 Hz |
| External Dimensions | 950 × 870 × 610 mm |
| Usable Internal Volume | 680 × 650 × 400 mm |
| Generator/Controller/Detector Cabinet | 1600 × 550 × 600 mm |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6050-T |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity in Test Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm |
| External Dimensions | 670 × 620 × 510 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6300 |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Range | 0–100 / 1,000 / 10,000 pphm |
| Response Time | 5 s |
| Detection Limit | 1 pphm |
| Accuracy | ±0.2% of reading |
| Repeatability | ±0.2% of full scale |
| Temperature Control Range | 15–70 °C (RT = 23 °C) |
| Temp. Accuracy | ±5 K |
| Temp. Ramp Rate | 0.4 K/min |
| Humidity Range | 30–80% RH |
| Humidity Accuracy | –1 to +4% RH |
| Humidity Stabilization Time to 95% | ≤20 min |
| Ozone Control Range | 20–200 pphm |
| Ozone Control Accuracy | ±1 pphm |
| Ozone Stabilization Time to 95% | 10 min |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 680 × 650 × 400 mm |
| External Dimensions | 950 × 870 × 610 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 7500 |
| Temperature Range | 26–60 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive ultraviolet (NDUV) absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm (standard) |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM 8000 |
| Chamber Volume | 8000 L |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV Absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity) |
| Airflow Velocity in Test Zone | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM-6300 |
| Internal Dimensions | 680 × 680 × 500 mm |
| External Dimensions | 1610 × 1500 × 1000 mm |
| Gas Flow Velocity | 8–700 mm/s |
| Air Exchange Rate | 50–500 L/min |
| Air Replacement Rate | 1–2000 dm³/h (33 L/min) |
| Temperature Range | RT to 70 °C ±0.5 °C |
| Humidity Range | 30–90 %RH (±1/+4 %RH) |
| Ozone Measurement Principle | Single-beam NDUV Photometry |
| Ozone Concentration Range | 0–1999 mg O₃/Nm³ or 0–1000 ppmv |
| Sensitivity | 0.001 ppmv |
| Accuracy | <1 % SCE |
| Linearity | 98 % SCE |
| Ozone Generation Method | Corona Discharge (COM-ADM) |
| Ozone Output Capacity | 10–2000 mg/h |
| Ozone Flow Rate | 100–2000 NL/h |
| Power Consumption | 3000 W |
| Voltage | 230 V, 10 A |
| Weight | 250 kg |
| Compliant Standards | ASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10 |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM6200-T-CL |
| Chamber Volume | 230 L |
| Internal Dimensions (H×W×L) | 50 × 68 × 68 cm |
| Total Dimensions (H×W×L) | 181 (+43) × 99 × 120 (+10) cm |
| Weight | 400 kg |
| Power Supply | 230/120 VAC, 50/60 Hz |
| Ozone Concentration Range | 0–1000 pphmv |
| Airflow Velocity (in chamber) | 8–16 mm/s (longitudinal, laminar flow) |
| Reynolds Number (Re) | 300–1000 |
| Loading Factor | G = 12 s/m (per ISO 1431-1) |
| Certified Ozone Analyzer | MP60602 |
| Ozone Generator | Maintenance-Free Type |
| Control System | Siemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI |
| Data Interface | RS232, USB |
| Safety Features | Catalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM6300-T-CL |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Ozone Generation | Maintenance-free corona discharge generator |
| Ozone Monitoring | Certified ozone analyzer (MP series) with closed-loop feedback control |
| Control System | Programmable logic controller (PLC) with interrupt-resume functionality for long-term durability testing |
| Air Circulation | Recirculating turbojet system integrated with catalytic ozone destruct unit and activated carbon filter |
| Sample Mounting | Dual-mode fixture—static test racks and dynamic rotating sample disc (4-position V-groove clamping) |
| Data Interface | RS232 serial port for real-time logging to ANSEROS on-board monitoring software |
| Chamber Configuration | Climate-controlled enclosure with temperature stabilization (ambient to +70 °C, ±0.5 °C uniformity) |