AnTing
Filter
Showing 1–30 of 68 results
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800B |
| Type | Benchtop Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 20 mL (angle rotor) |
| Power Supply | 220 V, 50 Hz, 40 W |
| Dimensions (D×H) | 245 mm × 210 mm |
| Weight | 4 kg |
| Construction | High-strength engineering plastic housing |
| Safety | Electronic lid lock |
| Application Class | General-purpose low-speed separation |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800C |
| Type | Benchtop Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 15 mL (angle rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing |
| Safety | Electronic door interlock |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 ×g |
| Rotor Type | Fixed-Angle Rotor |
| Rotor Capacity | 15 mL × 6 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Net Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Cooling | Non-refrigerated (ambient-temperature operation) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-4000B |
| Type | Benchtop Refrigerated Centrifuge |
| Rotor Configuration | Swing-Bucket (Horizontal) |
| Max Speed | 4000 rpm |
| Max RCF | 3600 × g |
| Max Capacity | 500 mL × 6 |
| Temperature Range | −20 °C to +30 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions (L×W×H) | 710 × 575 × 850 mm |
| Weight | 213 kg |
| Rotor Options | No.1 (500 mL × 6 / 50 mL × 24 / 10 mL × 72), No.2 (6 mL × 210), No.3 (192-well microplate, max 3500 rpm) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-4C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3776 ×g |
| Dimensions (L×W×H) | 580 mm × 630 mm × 650 mm |
| Weight | 160 kg |
| Power Supply | 220 V, 50 Hz, 750 W |
| Timer Range | 0–99 min |
| Rotor Configuration | Horizontal swing-out rotor |
| Standard Capacity Options | 500 mL × 4, 100 mL × 4, 50 mL × 16, 15 mL × 28, 10 mL × 48, 7 mL × 48, 5 mL × 48, or 192-well microplate support |
| Safety | Electronic door lock |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5-B |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 5000 rpm |
| Max RCF | 5000 × g |
| Max Capacity | 250 mL × 4 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions (L×W×H) | 590 mm × 460 mm × 675 mm |
| Weight | 83 kg |
| Rotor Configuration | Fixed-angle rotor |
| Construction | Reinforced polymer housing with structural steel frame |
| Safety | Electronic lid interlock system |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 6000 ×g |
| Max Capacity | 1200 mL × 6 (with No.1 swing rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 3 kW |
| Dimensions (L×W×H) | 860 mm × 750 mm × 955 mm |
| Weight | 337 kg |
| Rotor Configuration | Dual swing-out rotors (No.1: 1200 mL × 6 at 4000 rpm |
| No.2 | options include 500 mL × 6 / 50 mL × 24 / 10 mL × 72, all rated up to 5000 rpm) |
| Safety | Electronic door interlock system |
| Construction | Reinforced polymer housing with vibration-damping base |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B-C |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | ~4000 ×g |
| Max Capacity | 100 mL × 4 |
| Temperature Range | −20 °C to 30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Dimensions (L×W×H) | 500 × 590 × 780 mm |
| Weight | 120 kg |
| Rotor Configurations | Horizontal rotor with air shield (e.g., 100 mL × 4, 250 mL × 4, 15 mL × 16, etc.), Radioimmunoassay-specific rotor (6 mL × 96) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B-II |
| Type | Benchtop Refrigerated Centrifuge |
| Max. Speed | 5000 rpm |
| Max. RCF | 5000 × g |
| Max. Capacity | 250 mL × 4 (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Dimensions (L×W×H) | 460 mm × 510 mm × 680 mm |
| Net Weight | 245 kg |
| Rotor Type | Horizontal (swing-out) |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5200 |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4500 rpm |
| Max RCF | 5000 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 3 kW |
| Dimensions (L×W×H) | 650 × 710 × 835 mm |
| Weight | 250 kg |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic door interlock system |
| Compliance | Designed to meet IEC 61010-1 safety requirements for laboratory equipment |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 4500 × g |
| Max Capacity | 250 mL × 4 (horizontal rotor) |
| Rotor Configurations | Horizontal rotors for 6×96-well plates (6 mL × 96), 15 mL × 32, 25 mL × 56, 50 mL × 16, 10 mL × 36, 15 mL × 16, 50 mL × 8, 250 mL × 4 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 660 mm × 460 mm × 415 mm |
| Net Weight | 90 kg |
| Construction | Full stainless-steel housing with reinforced polymer structural components |
| Drive System | Frequency-converter-controlled brushless DC motor |
| Safety | Electronic door interlock, imbalance detection, automatic rotor recognition (via preset rotor profiles) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-6000B |
| Type | Benchtop Refrigerated Centrifuge |
| Max. Speed | 6000 rpm |
| Max. RCF | 7500 × g |
| Max. Capacity | 4 × 500 mL (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions (L×W×H) | 710 mm × 575 mm × 850 mm |
| Weight | 213 kg |
| Rotor Type | Horizontal swing-out |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-6000C |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 6000 rpm |
| Max RCF | 7500 ×g |
| Max Capacity | 4 × 500 mL (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Dimensions (L×W×H) | 740 × 575 × 840 mm |
| Weight | 220 kg |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Rotor Configuration | Horizontal swing-out rotor with air shield |
| Construction | Full stainless-steel body with high-strength polymer housing |
| Drive System | Frequency-controlled AC motor |
| Safety | Electronic door lock, automatic rotor recognition (optional), imbalance detection |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-12B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 12,000 rpm |
| Max RCF | 9,338 × g |
| Capacity | 4 × 100 mL (angular rotor) |
| Temperature Range | −20 °C to +30 °C |
| Timer Range | 0–99 min |
| Power Consumption | 1.5 kW |
| Dimensions (L×W×H) | 600 × 505 × 770 mm |
| Weight | 115 kg |
| Rotor Type | Fixed-angle |
| Enclosure Material | Reinforced polymer housing |
| Safety | Electronic door interlock system |
| Compliance | Designed per IEC 61010-1 for laboratory equipment safety |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-16G-II |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 16,000 rpm |
| Max RCF | 17,000 × g |
| Capacity | 12 × 10 mL (angular rotor) |
| Temperature Range | −20 °C to +30 °C |
| Timer Range | 0–99 min |
| Power Consumption | 1.5 kW |
| Dimensions (L×W×H) | 600 × 505 × 770 mm |
| Weight | 111 kg |
| Rotor Type | Fixed-angle |
| Safety | Electronic door lock |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-20B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 20,000 rpm |
| Max RCF | 43,825 × g |
| Max Capacity | 6 × 500 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 3 kW |
| Dimensions (L×W×H) | 790 × 665 × 950 mm |
| Weight | 277 kg |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-20G-II |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 20,000 rpm |
| Max RCF | 25,938 × g |
| Max Capacity | 6 × 50 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Dimensions (L×W×H) | 500 mm × 540 mm × 780 mm |
| Weight | 115 kg |
| Rotor Configuration | Fixed-angle rotor |
| Safety | Electronic door lock |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-21B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 0–21,000 rpm |
| Max RCF | 46,700 × g |
| Max Capacity | 6 × 500 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 3 kW |
| Dimensions (L×W×H) | 790 × 665 × 950 mm |
| Weight | 277 kg |
| Rotor Configuration | Fixed-angle rotor standard |
| Safety | Electronic door interlock system |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 × g |
| Rotor Capacity | 8 × 20 mL (angle rotor) |
| Timer Range | 0–30 min |
| Power Supply | 220 V, 50 Hz, 135 W |
| Dimensions (L×W×H) | 330 × 300 × 280 mm |
| Weight | 12 kg |
| Construction | Reinforced polymer housing with electronic safety lid lock |
| Compliance | Designed for general laboratory use under ISO/IEC 17025-aligned operational environments |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 × g |
| Rotor Type | Fixed-angle rotor |
| Capacity | 8 × 15 mL |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 380 mm × 480 mm × 330 mm |
| Net Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety interlock door |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 ×g |
| Rotor Type | Fixed-Angle |
| Rotor Capacity | 15 mL × 8 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Control System | Frequency-converter motor with capacitive touch panel interface |
| Compliance | Designed for GLP-compliant routine separation tasks in academic and QC laboratories |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIB |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 0–3600 rpm |
| Max RCF | 3040 ×g |
| Rotor Type | Swing-Bucket Horizontal Rotor |
| Max Capacity | 120 × 5 mL Vacuum Blood Tubes |
| Temperature Control | Refrigerated (operating range: 4–25 °C) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 550 mm × 700 mm × 770 mm |
| Net Weight | 144 kg |
| Drive System | Brushless Frequency-Controlled Motor |
| Safety Features | Electronic Door Interlock, Automatic Lid Lock During Operation |
| Noise Level | ≤65 dB(A) |
| Compliance | Designed for GLP-compliant clinical laboratories |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIC |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3000–5000 ×g |
| Max Capacity | 1000 mL × 4 (horizontal rotor) |
| Rotor Configurations | 500 mL × 6, 50 mL × 24, 15 mL × 42, 10 mL × 72, 7 mL × 72, 5 mL × 72, 6 mL × 210, 50 mL × 24, 15 mL × 54, 5 mL × 96, 192-well microplate |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 700 mm × 800 mm × 900 mm |
| Weight | 160 kg |
| Enclosure Material | Reinforced engineering plastic |
| Safety | Electronic door interlock system |
| Brand | Anting |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIZ |
| Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge |
| Cooling | Refrigerated |
| Rotor Type | Horizontal Swing-Bucket Rotor |
| Maximum Capacity | 120 × 5 mL Vacuum Blood Tubes |
| Maximum Speed | 3600 rpm |
| Maximum RCF | 3040 × g |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 550 mm × 700 mm × 770 mm |
| Weight | 145 kg |
| Drive System | Brushless Frequency-Controlled Motor |
| Safety | Electronic Door Lock Interlock |
| Noise Level | Low-Noise Operation |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-36C |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–3600 rpm |
| Max RCF | 3100 × g |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Max Capacity | 4 × 1000 mL |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 715 × 550 × 435 mm |
| Weight | 90 kg |
| Safety | Electronic Lid Lock |
| Construction | Reinforced Polymer Housing |
| Compliance | Designed for GLP-compliant routine separation workflows |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 20 mL (angle rotor) |
| Timer Range | 0–30 min |
| Power Supply | 220 V, 50 Hz, 65 W |
| Dimensions (L×W×H) | 280 mm × 310 mm × 265 mm |
| Net Weight | 9 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Compliance | Designed for general laboratory separation per ISO 13485-aligned manufacturing practices |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4000C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3300 × g |
| Max Capacity | 50 mL × 4 (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 660 mm × 460 mm × 415 mm |
| Weight | 80 kg |
| Rotor Configuration | Horizontal swing-out rotor with safety hood |
| Drive System | Frequency-controlled AC motor |
| Construction | Reinforced polymer housing with precision-machined aluminum rotor chamber |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-40B |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 4328 ×g |
| Rotor Capacity | 100 mL × 4 (swinging bucket), 50 mL × 8, or 15 mL × 16 (all at ≤4000 rpm) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 505 mm × 450 mm × 425 mm |
| Net Weight | 53 kg |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic door interlock system |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-40C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3180 × g |
| Max Capacity | 100 mL × 4 (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 660 mm × 460 mm × 415 mm |
| Weight | 70 kg |
| Rotor Type | Swing-Bucket Horizontal Rotor |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic door interlock system |
| Compliance | Designed to meet general laboratory safety and electromagnetic compatibility (EMC) requirements per IEC 61000-6-3/6-2 |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 15 mL (angle rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 380 mm × 480 mm × 330 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Compliance | Designed for general laboratory use under ISO/IEC 17025-aligned workflows |