Anton Paar Brabender
Filter
Showing all 23 results
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Measurement Principle | Automated Titration-Based Oil Absorption (OAN) |
| Construction | Stainless Steel Housing |
| Software | Integrated PC-Based Control with Audit Trail & Data Export |
| Sample Handling | Dedicated Mixing Discs for Carbon Black & Silica |
| Viscosity Range | Up to 1,000,000 mPa·s |
| Solvent Compatibility | NMP, Paraffin Oil, and Other Standard Oils |
| Automation Level | Fully Automated Titration, Dosing, Mixing, Endpoint Detection |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Construction | Stainless steel housing |
| Automation | Software-controlled titration system |
| Titration Range | Adjustable dosing rate, suitable for viscosities up to 1,000,000 mPa·s |
| Solvent Compatibility | Compatible with aggressive solvents (e.g., NMP) |
| Data Management | Real-time result comparison, scheduled measurements, CSV/Excel export |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction (DIN EN ISO 15512:2019) |
| Resolution | 0.0001% H₂O |
| Application | Residual Moisture Analysis in Thermoplastics & MFR Sample Preparation |
| Compliance | Fully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics |
| Software | Aquatrac Control Software with LIMS/ERP integration capability |
| Data Integrity | Audit trail, user access levels, electronic signatures (21 CFR Part 11 ready) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction under Vacuum |
| Compliance | DIN EN ISO 15512:2019 |
| Resolution | 0.0001% H₂O (w/w) |
| Application Scope | Polymer Residual Moisture Analysis & MFR Sample Conditioning |
| Software | Aquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability |
| Regulatory Alignment | Supports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ElaTest |
| Density Measurement Range | 0.8–2.6 g/cm³ |
| Temperature Range | 0–40.0 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 40–120 cm³ |
| Application | Density of uncured rubber and rubber compounds |
| Instrument Type | Benchtop Laboratory Densitometer |
| Detection Principle | Pneumatic (gas displacement) density measurement |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Extensograph-E |
| Compliance | ISO 27971, AACC Method 54-10, ICC Standard No. 115 |
| Sample Capacity | Standard (300 g dough) and Mini (100 g dough) configurations available |
| Measurement Principle | Uniaxial tensile deformation under controlled temperature and humidity |
| Data Output | Force (N), Extensibility (mm), Energy (mJ), Resistance to Extension (R, N), Ratio R/E, Curve Area Integration |
| Software Platform | MetaBridge v4.x with audit trail, user roles, and electronic signature support |
| Connectivity | OPC UA, CSV export, LIMS/ERP integration via REST API |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | FarinoGraph |
| Compliance | ICC, AACCI, ISO 5530-1, ISO 21415 |
| Measurement Unit | Brabender Unit (BU) / Farinograph Unit (FU) |
| Stirring Capacity | 10 g to 300 g |
| Water Dosage | Automated via AquaInject module |
| Data Management | MetaBridge web-based software |
| Connectivity | LIMS/ERP integration supported |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | FarinoGraph |
| Weight (without S300 mixer) | 56 kg |
| Weight (with S300 mixer) | 74 kg |
| Dimensions (W × H × D) | 430 mm × 630 mm × 740 mm |
| Torque | 28 N·m |
| Speed Range | 0–200 rpm |
| Power Supply | 230 V (184–264 V) + N + PE / 50–60 Hz / 4.3 A / 1 kW or 115 V (88–126 V) + PE / 50–60 Hz / 8.7 A / 1 kW |
| Interfaces | 4 × USB, 1 × HDMI, 2 × LAN |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Entity | Authorized Distributor |
| Origin Category | Imported |
| Model | GlutoPeak |
| Pricing | Available Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MetaStation |
| Instrument Type | Torque Rheometer |
| Sample Type | High-Viscosity Materials |
| Sample State | Molten or Paste-Like |
| Bearing Type | Mechanical Bearings |
| Frequency Range | 10⁻³–628 rad/s |
| Minimum Rotational Speed | 0.2 min⁻¹ |
| Maximum Torque | 500 N·m |
| Maximum Rotational Speed | 3000 rpm |
| Torque Resolution | <100 nN·m |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA / Aquatrac-V |
| Measurement Principle | Gravimetric (MT-CA), Calcium Hydride Reaction + Vacuum Pressure Monitoring (Aquatrac-V) |
| Moisture Range | 0.1% to 99.9% (MT-CA) |
| Compliance | DIN EN ISO 15512:2019, ICC 113, ISO 712, EC Tobacco Specifications |
| Software | MetaBridge v3.x (FDA 21 CFR Part 11 compliant audit trail, LIMS/ERP integration, GLP/GMP workflow support) |
| Sample Throughput | Up to 10 samples per run (MT-CA) |
| Standards Support | Preloaded methods for flour, tobacco, polymers, pasta, coffee, building materials |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA |
| Measurement Principle | Thermogravimetric (Heated Chamber Drying) |
| Moisture Range | 0.1% to 99.9% |
| Sample Capacity | Up to 10 positions |
| Compliance | ICC Standard 114, ISO 712, EC Tobacco Directive 2001/32/EC, USP <921>, ASTM D4457 |
| Software | MetaBridge v3.x (Web-based, Browser-Accessible) |
| Data Integrity | Audit Trail, User Access Levels, Electronic Signatures (21 CFR Part 11 Ready) |
| Footprint | Compact Benchtop Design |
| Interface | Integrated Touchscreen PC, Ethernet/Wi-Fi Connectivity |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model Series | Quadrumat Junior / Quadrumat Senior |
| Application | Laboratory-scale milling of wheat, durum, rye, barley and other cereals for flour quality analysis |
| Compliance | Designed in accordance with ISO 27971 (Cereal and cereal products — Determination of milling yield), ISO 5528 (Cereals — Sampling), and aligned with AACC International Method 26–10A (Milling of Wheat to Produce Flour for Baking Tests) |
| Key Features | Dual-roller (Junior) and quad-roller (Senior) configuration |
| Standard Sieve Aperture | 280 µm |
| Max. Feed Moisture Content | 18% w/w |
| Cleaning | Tool-free circular sieve removal |
| Optional Integration | Compatible with Brabender Debranning Unit (TorqueTec GmbH) for ash reduction and yield optimization |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | SM 4 |
| Grinding Principle | Adjustable-gap roller mill with dual counter-rotating corrugated rollers |
| Max. Feed Capacity | 200 g per batch |
| Adjustable Gap Range | 0.1–3.0 mm (micrometer-adjustable) |
| Motor Power | 0.75 kW |
| Speed | 250 rpm (fixed) |
| Construction | Stainless steel housing, food-grade contact materials |
| Compliance | ISO 6540, ISO 712, ISO 20483, AOAC 991.20, AACC 22–10 |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TSSR |
| Application | Isothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method) |
| Compliance Context | ASTM D624, ISO 37, ISO 6982, DIN 53515 |
| Software | Automated real-time data acquisition, spectral evaluation, and GLP-compliant storage |
| Measurement Principle | Torque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender GmbH) |
| Model | TwinLab Series |
| Configuration Options | Twin-screw extruder, single-screw extruder (e.g., 19/25 mm), batch mixer |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation modular drive unit |
| Control Software | MetaBridge v3.x |
| Barrel Design | Split-barrel with quick-release liner |
| Material Contact Parts | Wear- and corrosion-resistant high-alloy steel (up to 500 °C service temperature) |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TwinLab Tobacco |
| Pricing | Upon Request |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TwinLab |
| Configuration | Modular Twin-Screw / Single-Screw / Batch Mixer |
| Drive Unit | MetaStation |
| Control Software | MetaBridge |
| Temperature Range | Up to 500 °C |
| Throughput Range | 0.05–100 kg/h |
| Screw Diameter Options | 19 mm, 25 mm, and scalable modular configurations |
| Barrel Design | Split-barrel with removable liners |
| Material Compatibility | Liquids, powders, granules, high-abrasive & high-corrosive compounds |
| Compliance | Designed for GLP/GMP-aligned workflows, data audit trail capable (21 CFR Part 11–ready architecture) |
| Data Export | CSV, PDF, email-integrated reporting |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TwinLab Rubber |
| Screw Diameter | 12 / 20 / 30 mm |
| L/D Ratio | 36 / 40 |
| Torque Capacity | 14 / 30 / 60 / 150 N·m |
| Operating Temperature | >500 °C |
| Throughput Range | 0.05–100 kg/h |
| Drive System | MetaStation Modular Drive Platform |
| Software | MetaBridge (Cross-Platform, Cloud-Ready, Audit-Trail Capable) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Viscograph-E |
| Sample Mass | 40 g |
| Compliance | ICC Standard No. 162, AACCI Method 76-15A |
| Temperature Control Accuracy | ±0.1 °C |
| Probe Type | Direct-contact immersion Pt100 sensor |
| Construction | Stainless steel bowl and stirrer |
| Software Platform | MetaBridge v3.x (supports FDA 21 CFR Part 11 audit trail, LIMS integration, multi-instrument synchronization) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Amylograph-E |
| Compliance | ICC Standard 110/1, ISO 7973, AACCI Method 22-05 |
| Temperature Ramp | 30–95 °C at 1.5 °C/min |
| Torque Measurement Range | 0–1000 mNm |
| Resolution | 0.1 mNm |
| Sample Volume | 50 g flour + 50 mL water (standard) |
| Real-time Sample Temperature Monitoring | Yes, direct-contact Pt100 sensor |
| Data Output | BU (Brabender Units) / AU (Amylograph Units) |
| Software Integration | MetaBridge Standalone v3.0+ |
| Regulatory Alignment | Supports GLP-compliant audit trails, 21 CFR Part 11–ready configuration options |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ExtensoGraph |
| Compliance | ICC Standard No. 110, AACC Method 54-10, ISO 27971 |
| Temperature Control Range | 20–40 °C (±0.2 °C) |
| Humidity Control Range | 30–95% RH (±2% RH) |
| Measurement Resolution | 0.1 mm (extension), 0.01 N (force) |
| Sample Capacity | Up to 2 × 300 g dough pieces per test cycle |
| Data Export Formats | CSV, XML, PDF |
| Software Platform | MetaBridge v3.2 (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user role management) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender) |
| Model | ViscoQuick |
| Heating Rate | +20 °C/min |
| Cooling Rate | −15 °C/min |
| Operating Temperature Range | ≤20 °C to ≥95 °C |
| Measurement Principle | Rotational Viscometry (Torque-based) |
| Data Interface | Web-based MetaBridge Software |
| Compliance Support | ASTM D445, ISO 3104, ISO 2555, USP <911>, GLP/GMP-ready audit trail |