AOE
Filter
Showing 1–30 of 44 results
| Brand | AOE |
|---|---|
| Model | 6400A |
| Origin | Shanghai, China |
| Type | Benchtop Flame Emission Spectrometer |
| Detection Elements | K, Na, Li, Ca, Ba |
| Optical System | Interference Filter-Based Monochromator |
| Detector | Silicon Photocell |
| Display | LCD |
| Sample Uptake Rate | <6 mL/min |
| Response Time | <8 s |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 6 readings) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K: ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Na | ≤0.03 mmol/L (0.0500–0.400 mmol/L) |
| Detection Limit | K: ≤0.004 mmol/L |
| Na | ≤0.008 mmol/L |
| Potassium Filter | Peak Wavelength Tolerance ≤±7 nm, FWHM ≤15 nm, Background Transmittance ≤0.5% |
| Sodium Filter | Peak Wavelength Tolerance ≤±5 nm, FWHM ≤15 nm, Background Transmittance ≤0.5% |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A360 |
| Price Range | USD 4,200 – 7,000 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A380 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 220 nm & 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A390 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 2.0, 4.0, 5.0 nm |
| Stray Light | ≤0.03% T at 360 nm |
| Display | 6.5K-color TFT LCD (800 × 480) |
| Data Storage | 240 calibration curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.1 host port for firmware update |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), CMC License (PRC Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A560 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.02% T at 360 nm |
| Wavelength Scanning | Automatic |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A580 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A590 |
| Optical System | Dual-Beam Ratio-Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Display | 800 × 480 TFT color LCD (65K colors) |
| Data Storage | 240 curves × 240 data points onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Software Copyright Registration) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FP640 |
| Price Range | USD 720–1,430 (FOB Shanghai) |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 1-min interval) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K: ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Na | ≤0.03 mmol/L (0.0500–0.400 mmol/L) |
| Detection Limit | K: ≤0.004 mmol/L |
| Na | ≤0.008 mmol/L |
| K Interference Filter | Peak Wavelength Tolerance ≤±7 nm |
| Na Interference Filter | Peak Wavelength Tolerance ≤±5 nm |
| Filter Bandwidth (FWHM) | ≤15 nm for both K and Na filters |
| Background Transmittance | ≤0.5% |
| Response Time | <8 s |
| Sample Aspiration Rate | <6 mL/min |
| Display | LCD with integrated parameter readout |
| Optical System | Fixed-wavelength interference filters |
| Detector | Silicon photodiode |
| Measurement Range (as elemental concentration) | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FP6410 |
| Price Range | USD 1,400–2,800 |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 1-min interval) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Detection Limit | K ≤0.004 mmol/L |
| Filter Peak Wavelength Tolerance | K ≤7 nm |
| Filter Bandwidth (FWHM) | ≤15 nm (K & Na) |
| Filter Background Transmittance | ≤0.5% |
| Response Time | <8 s |
| Sample Aspiration Rate | <6 mL/min |
| Display | LCD |
| Optical Filtering | Interference Filters |
| Photodetector | Silicon Photocell |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | ND300 |
| Optical Design | Single-Beam |
| Detector | 2048-Pixel Linear CCD Array |
| Wavelength Range | 185–910 nm |
| Spectral Bandwidth | 1.8 nm (FWHM at Hg 253.7 nm) |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.1% (at 220 nm & 360 nm) |
| Minimum Sample Volume | 0.5 µL |
| dsDNA Detection Range | 2–15,000 ng/µL |
| Absorbance Accuracy | ±0.002 Abs (1 mm pathlength) |
| Measurement Time | <0.5 s |
| Connectivity | USB 2.0, Wi-Fi, USB Flash Drive Firmware Update |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ND500 |
| Price Range | USD 9,500 – 13,600 (FOB Shanghai) |
| Optical Design | Single-Beam |
| Detector | 2048-Pixel Linear CCD Array |
| Wavelength Range | 185–910 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Photometric Accuracy | ±0.002 Abs (at 1 mm pathlength) |
| Minimum Sample Volume | 0.5 µL |
| dsDNA Detection Range | 2–15,000 ng/µL |
| Scan Speed | <0.5 s per full spectrum |
| Spectral Resolution | ≤1.8 nm FWHM (measured at Hg 253.7 nm line) |
| Light Source | Pulsed Xenon Lamp |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Update | USB Flash Drive–Based Firmware Upgrade (Lifetime Free) |
| Brand | AOE |
|---|---|
| Model | OD600 |
| Instrument Type | Benchtop Microbial Turbidimeter |
| Detection Wavelength | 600 nm ± 1 nm |
| Bandwidth | 10 nm |
| Absorbance Range | −0.3 to 3.0 Abs |
| Absorbance Accuracy | ±0.005 Abs (0–0.5 Abs), ±0.01 Abs (0.5–1.0 Abs) |
| Absorbance Repeatability | ≤0.002 Abs |
| Light Source | High-Stability Solid-State LED (20,000 h lifetime) |
| Detector | Silicon Photodiode |
| Sample Volume | 200–3000 µL |
| Display | 8-inch HD Color TFT LCD (1024 × 600) |
| Data Storage | 128 MB internal memory |
| Data Export | USB flash drive & microSD card support |
| Built-in Thermal Printer | Yes (auto/batch print) |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V / 3 A |
| Dimensions (W × D × H) | 290 × 260 × 100 mm |
| Weight | 2.15 kg |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T1 |
| Instrument Architecture | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.001 Abs |
| Display | 7-inch TFT LCD Touchscreen (480 × 272 pixels) |
| Data Export | USB flash drive interface |
| Software Features | Audit Trail, GMP/GLP-compliant data logging, lifetime free firmware & software updates |
| Sample Holder Compatibility | Adjustable cuvette holder for 1–5 cm pathlength cells |
| Optical System | Holographic grating (1200 lines/mm) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T1v |
| Optical System | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1020 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Selection |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T at 360 nm |
| Noise Level | ±0.001 Abs |
| Display | 7-inch 480×272 TFT True-color Touchscreen |
| Data Output | USB flash drive export |
| Software Features | Audit Trail, GMP/GLP-compliant data logging |
| Supported Cuvette Pathlengths | 1–5 cm |
| Compliance | Meets pharmacopoeial requirements (ChP, USP <857>, EP 2.2.25) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T2 |
| Price Range | USD 1,400–2,800 |
| Optical Configuration | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | ±3.8 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T (at 220 nm and 360 nm) |
| Noise Level | ±0.001 Abs |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T2v |
| Price Range | USD 700–1,400 |
| Optical Design | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | ±3.8 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1%T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.001 Abs (at 500 nm, 0 Abs) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T5 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Automatic |
| Spectral Bandwidth | 4.0 nm (±3.8 nm) |
| Wavelength Accuracy | ±0.4 nm (±0.3 nm at 546.1 nm) |
| Stray Light | ≤0.04% T (at 220 nm and 360 nm) |
| Wavelength Repeatability | ≤0.2 nm |
| Photometric Noise | ±0.0005 Abs (0–0.5 Abs), ±0.0004 Abs (0.5–1.0 Abs) |
| Display | 7-inch TFT LCD Touchscreen (1024 × 800 resolution) |
| Data Export | USB flash drive interface |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Sample Handling | Standard 6-position automatic cuvette changer (1–5 cm pathlength support) |
| Software Compliance | Audit trail enabled, 21 CFR Part 11–ready configuration options |
| Maintenance | Lifetime free firmware and software updates |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T6 |
| Price Range | USD 2,800–4,300 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm (±1.6 nm) |
| Wavelength Accuracy | ±0.4 nm (±0.3 nm at 546.1 nm) |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T (at 220 nm and 360 nm) |
| Absorbance Noise | ±0.0005 Abs (0–0.5 Abs), ±0.0004 Abs (0.5–1.0 Abs) |
| Display | 7-inch TFT LCD Touchscreen (1024 × 800 resolution) |
| Data Interface | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Sample Holder | Integrated 6-position Automatic Cuvette Changer (supporting 1–5 cm pathlength cells) |
| Software Compliance | Audit Trail Enabled, 21 CFR Part 11 Ready (User Authentication, Electronic Signature Support, Immutable Log History) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | U110Pro |
| Price Range | USD 700–1,400 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 200–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 Abs/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | U120Pro |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 195–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.1% T at 220 nm and 340 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 Abs/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | UV-1000 |
| Optical System | Single-beam with dual-beam ratio monitoring |
| Detector Type | Photocell |
| Wavelength Range | 200–1020 nm |
| Wavelength Accuracy | ±1.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 4.0 nm |
| Stray Light | ≤0.1% T @ 360 nm |
| Display | 128 × 64 dot-matrix LCD |
| Data Output | USB port (U-disk export), RS-232 serial printer interface |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | UV-1200 |
| Optical System | Single-beam with dual-beam ratio monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 195–1020 nm |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T @ 360 nm |
| Display | 128 × 64 dot-matrix LCD |
| Data Output | USB port (U-disk export), RS-232 serial printer interface |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1600 |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1600PC |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1800 |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1800PC |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UV-1900 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | Onboard memory for 240 calibration curves (240 data points per curve) |
| Data Export | USB 2.0 × 2 (for printer & PC transfer), USB 1.0 for firmware update |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRxxxxxx) |
| Compliance | ISO 9001:2015, CE Marking, CMC License (PRC Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1900PC |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | Onboard memory for 240 calibration curves (240 data points per curve) |
| Data Export | USB 2.0 port for direct U-disk export |
| Printing Interface | PCL-compatible USB printer support (A4 format) |
| Firmware Upgrade | USB-based one-click update via AOE official website (instrument serial number required) |
| Certifications | ISO 9001:2015, CE (EN 61010-1, EN 61326-1), CMC (China Metrology Certification), RoHS Directive 2011/65/EU |
| Software Compliance | Basic Control Software registered with the National Copyright Administration of the People’s Republic of China (Certificate No. 2021SRXXXXXX) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1000 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | V-1200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1020 nm |
| Wavelength Scanning | Motorized Auto-Scan |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.1% T @ 360 nm |
| Display | 128 × 64 Dot-Matrix LCD |
| Data Output | USB Port (U-disk export), RS-232 Serial Print Interface |
| Software | AOE Basic Spectroscopy Suite (Certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE, CMC (China Metrology Certification), RoHS Directive 2011/65/EU |