AOPU
Filter
Showing all 10 results
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1200 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1301 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1302 |
| Detection Elements | K, Na, Ca |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Optical System | Interference filter-based monochromator with three dedicated channels (K, Na, Ca) |
| Detector | Silicon photovoltaic cell |
| Calibration Modes | Linear, segmented linear, and quadratic polynomial fitting |
| Stability | ≤ 3% RSD over 15 s |
| Linearity Error | K ≤ 0.005 mmol/L |
| Ignition System | One-touch electronic ignition with flame-ionization safety cutoff and auto-alarm (8 s timeout) |
| Interface | RS232 serial port for PC or printer connectivity |
| Dimensions | 440 × 310 × 500 mm |
| Weight | 12.5 kg |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 250 W |
| Operating Environment | 10–35 °C, RH ≤ 85%, vibration-free, non-corrosive, non-explosive atmosphere |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1401 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Detection Limits | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Aspiration Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1402 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.0004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1500 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Aspiration Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1500 GMP Edition |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limits | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | FP640 |
| Price | USD 1,280 (FOB Shanghai) |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Uptake Rate | < 6 mL/min |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 7-inch Color Touchscreen |
| Ignition System | One-Touch Auto-Ignition with Flame Ionization Safety Cut-off |
| Fuel Compatibility | Liquefied Petroleum Gas (LPG), Propane, or Butane |
| Linear Error | K ≤ 0.005 mmol/L |
| Stability | ≤ 3% max variation within 15 s |
| Operating Environment | 10–35 °C, RH ≤ 85%, Stable Horizontal Surface, No Strong EMI/Vibration, Proper Grounding, 220 V ± 10%, 50 Hz ± 1 Hz, 250 W Max |
| Dimensions | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Standard Configuration | Main Unit, Integrated Air Compressor, Calibration Standards, Capillaries, Filters, User Manual, and Safety Accessories |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FP6400A |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 7-inch Color Touchscreen |
| Ignition System | One-Touch Ignition with Flame Ionization Safety Cut-off |
| Fuel Compatibility | Liquefied Petroleum Gas (LPG), Propane, or Butane |
| Linear Error | K ≤ 0.005 mmol/L |
| Stability | ≤ 3% RSD over 15 s |
| Operating Environment | 10–35 °C, RH ≤ 85%, Stable Horizontal Surface, Grounded 220 V ± 10%, 50 Hz ± 1 Hz, 250 W Max |
| Dimensions | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FP650 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
