| Model | APL-AGS-36 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 132 positions |
| Minimum Injection Volume | 1 mL |
| Quantitative Loop Volume | 1 mL |
| Sample Tray Configuration | 36-position base (expandable in 12-position modules) |
| Compatible Sampling Devices | Gas-tight syringes and Tedlar®/aluminized gas bags |
| Tubing Material | PTFE |
| Valve Body | PEEK |
| Valve Core | Polyimide (PI) |
| Carrier Gas Line Purge Flow Rate | Up to 0.5 L/min |
| Injection Precision | R² ≥ 0.9999 for total hydrocarbons and methane peak areas across five replicate injections |
| Dimensions (L×W×H) | 450 × 500 × 430 mm |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-AS-24 |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 24 positions (expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Maximum Injection Volume | 250 µL |
| Replicate Injections per Vial | up to 99 |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Method Storage | up to 20 methods |
| Needle Wash Cycles | up to 99 |
| Pump Draw Cycles | up to 99 |
| Viscosity Delay | 0–60 s |
| Dwell Time Pre-/Post-Insertion | 0–120 s |
| Injection Timing Reproducibility (Dual-Tower Mode) | < 1 ms |
| Communication Interfaces | Modbus RTU, USB 2.0 |
| Operating Temperature | −20 °C to 50 °C |
| Storage Temperature | −40 °C to 70 °C |
| Operating Humidity | 10–90% RH |
| Storage Humidity | 5–90% RH |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | APL-FHS 300 |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 180-position liquid tray / 70-position headspace tray / 70-position SPME tray |
| Minimum Liquid Injection Volume | 0.01 µL |
| Motion Control | XYZ three-axis precision positioning |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | APL-GC-901A |
| Temperature Control Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 80°C/min |
| Cooling Time | <7 min (250°C to 50°C) |
| Carrier Gas Flow Range | 0–500 mL/min |
| Carrier Gas Pressure Range | 0–0.6 MPa |
| Injector Maximum Temperature | 350°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmed Temperature Ramping | Up to 16 steps |
| Ramp Rate Adjustable | 0.1–60°C/min |
| Temperature Stability | ±0.1°C |
| Display | 7-inch capacitive touchscreen LCD |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously installed) |
| Injection Options | Packed column, capillary column, dual-capillary, valve-based gas injection, headspace, thermal desorption, autosampler-ready |
| Column Oven Dimensions | 260 × 270 × 235 mm |
| Communication Interface | Ethernet (IEEE 802.3) |
| External Events | 8 inputs, 2 auxiliary outputs |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 16 positions (all heated) |
| Vial Size Compatibility | 10 mL and 20 mL (20 mL standard) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Purge Flow Rate | 0–400 mL/min (continuously adjustable) |
| Precision | RSD ≤1.5% (ethanol in water, 400 ppm, n=5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Vial Capacity | 40 positions |
| Vial Size Compatibility | 20 mL (standard), 10 mL (optional) |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Pressure-Controlled Injection Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 60 positions (15 heated positions) |
| Backup Positions | 20 |
| Vial Size Compatibility | 10 mL and 20 mL (standard) |
| Oven Temperature Range | Ambient to 260 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Pressure-Controlled Injection | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Injection Volume Control | Pressurization time + regulated pressure |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | APL-PT-100 |
| Sample Capacity | 100 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Purge Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | −30 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | APL-PT-75 |
| Sample Tray Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | –30 °C |
| Purge Gas Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Sample Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-1 |
| Instrument Type | Primary Thermal Desorber |
| Automation Level | Fully Automatic |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C to 25 °C (Note: Input states “25” — interpreted as upper limit of ambient-cooled trap |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-100 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 400 °C (±1 °C) |
| Secondary Desorption Temperature Range | −35 °C to 400 °C (±1 °C) |
| Secondary Flash Heating Rate | ≥3000 °C/min |
| Valve Oven Temperature Range | Ambient to 300 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 300 °C (±1 °C) |
| Cold Trap Temperature Range | −35 °C (±0.5 °C) |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Efficiency | >98% |
| Sample Capacity | 100 positions |
| Tube Standard | ASTM D6196-22 / ISO 16017-1 compliant 89 mm × 6.4 mm (3.5″ × 1/4″) adsorption tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-2 |
| Instrument Type | Two-Stage Thermal Desorber, Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Count | 1 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve & Injection Port Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature | −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-50D |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Desorption Temperature Range | –35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | –35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-TOC-30 |
| Instrument Category | Graphite Block Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | 30 |
| Temperature Range | Ambient to 350 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electric Resistance Heating |
| Reagent Dispensing Channels | None |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 1600 W |
| Well Dimensions | Ø30 mm × 55 mm depth |
| Inter-Well Temperature Uniformity | < ±1.0 °C (20–250 °C) |
| Control System | Detachable PID Controller with LCD Digital Display |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | APL-TOC-60 |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | 60 |
| Temperature Range | Ambient to 350 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electric Resistance Heating with Isostatically Pressed High-Purity Graphite Block |
| Reagent Channels | None |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 4000 W |
| Well Dimensions | Ø30 mm × 55 mm depth |
| Inter-Well Temperature Uniformity | < ±1.0 °C (25–250 °C) |
| Control System | Separated PID Controller with LCD Digital Display |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | APL-ASE200 |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0–20 MPa |
| Extraction Cell Volume | 40 mL (standard) |
| optional volumes | 1, 5, 10, 22, 66, and 100 mL |
| Typical Extraction Time | 8–20 min per sample |
| Dimensions | 600 × 600 × 700 mm |
| Compliance | HJ 782–2016, HJ 783–2016, GB/T 23200.9–2016, ASTM D7567–2009 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | BUS |
| Price Range | USD 56,000 – 70,000 |
| Cavity Class | Industrial Grade |
| Maximum Sample Capacity | 40 vessels |
| Microwave Source | Dual Magnetron |
| Max Temperature | 305 °C |
| Max Pressure | 22,000 psi |
| Input Power | 220 VAC, 50 Hz, 15 A |
| Total System Power | 3600 W |
| Microwave Output Power | 2200 W |
| Output Mode | Non-pulsed, continuous microwave (0–2200 W adjustable) |
| Cavity Volume | 66 L |
| Cavity Material | 316 stainless steel with multi-layer PTFE-based high-temp corrosion-resistant coating |
| Cooling | Integrated high-turbulence forced-air cooling system |
| Safety | Aerospace-grade composite fiber outer vessels with 3D vertical explosion containment, real-time pressure/temperature monitoring, electromagnetic leakage < 1 mW/cm² (per GB 10436 & IEC 61000-3-2) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CFF-2.5-12T |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 2500 W |
| Time to Reach 1000 °C | ≤20 min |
| Heating Element | Fe-Cr-Al Alloy Wire |
| Internal Chamber Dimensions | 200 × 120 × 80 mm |
| Chamber Volume | 2 L |
| Operating Voltage | AC 220 V, 50 Hz |
| Control System | PID Temperature Controller |
| Insulation Material | High-Purity Alumina-Silica Ceramic Fiber |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | DK-400 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Manual Operation |
| Vial Heating Range | Ambient to 250 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Sample Loop Volume | 1.0 mL |
| Vial Capacity | 9 positions |
| Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-7890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5 °C above ambient to 420 °C (1 °C increment programmable) |
| Maximum Oven Operating Temperature | 400 °C |
| Heating Rate | Up to 40 °C/min |
| Cooling Rate | 280 °C → 50 °C in ≤8 min |
| Carrier Gas Flow Control Range | 0–50 mL/min |
| Carrier Gas Pressure Control Range | 0–0.35 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.35 MPa |
| Total Injector Flow Setting Range | 0–500 mL/min |
| Temperature Stability (≤180 °C) | ±0.01 °C |
| Temperature Stability (full range) | ±0.1 °C |
| Programmable Temperature Ramping | 7-stage |
| Independent Temperature Control | Dual vaporizers (capillary & packed column) |
| Detector Configuration | FID (Hydrogen Flame Ionization Detector) |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤5×10⁻¹⁴ A |
| FID Drift | ≤1×10⁻¹³ V/h |
| FID Linear Dynamic Range | ≥10⁷ |
| Column Compatibility | Up to three packed columns or two capillary columns simultaneously |
| Detector Capacity | Up to three detectors + methanizer |
| Optional Features | Integrated AD conversion circuit, cryogenic oven operation (dry ice/liquid nitrogen), dual rear doors with intelligent control, ceramic or quartz jet nozzles |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-GC-901 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-Down Rate | 0.1–80 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | Ambient to 450 °C |
| Injector Pressure Setpoint Range | 0–0.6 MPa |
| Injector Total Flow Setpoint Range | 0–100 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmable Temperature Steps | 16 stages |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 detectors (FID, TCD, ECD, FPD, NPD selectable) |
| Injection Modes | Packed column, capillary column, valve injection, headspace (with optional autosampler), thermal desorption |
| EPC/EFC Modes | Constant-flow and constant-pressure |
| Supported Gases | N₂, H₂, Air, He, Ar |
| EPC Pressure Resolution | 0.01 psi |
| EPC Flow Resolution | 0.01 mL/min |
| Communication Interface | 10/100 M adaptive Ethernet with embedded TCP/IP stack |
| Software | iBrainChrom workstation supporting up to 253 concurrent GC systems, 21 CFR Part 11 compliance (audit trail, role-based user permissions, electronic signatures), Modbus RTU protocol for DCS integration |
| Brand | APL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 8°C above ambient to 425°C |
| Oven Ramp Rate | Up to 75°C/min |
| Carrier Gas Pressure Control Range | 0–689.47 kPa (0–100 psi) |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–689.47 kPa |
| Injector Total Flow Setting Range | 0–100 psi |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | 104 |
| Max. Heating Temperature | 350 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Medium | Isostatically Pressed High-Purity Graphite |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 4000 W |
| Heating Block Dimensions | 104 × Ø30 mm × 55 mm (D × H) |
| Inter-Well Temperature Uniformity | ≤ ±1.5 °C (RT–250 °C) |
| Control System | Detached PID Controller with LCD Digital Display |
| Heating Method | Full Perimeter Surround Heating |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GD12 |
| Instrument Type | Graphite Block Digestion System |
| Temperature Range | Ambient to 250 °C |
| Heating Method | High-Purity Graphite Block with PFA Coating |
| Temperature Accuracy | ±1 °C |
| Max Power | 1.6 kW |
| Standard Sample Configuration | 12 × Ø55 mm holes (depth: 110 mm) |
| Uniformity | ±1.5 °C across all positions (20–210 °C) |
| Control System | PID-based Digital Temperature Controller with Programmable Ramp/Soak Profiles |
| Remote Interface | RS-232 Serial Communication Port |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Digestion System |
| Number of Digestion Positions | 25 |
| Max. Heating Temperature | 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Medium | Highly Uniform Graphite Block with PTFE Coating |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1600 W |
| Temperature Setting Range | Ambient to 250 °C (1 °C increments) |
| Timer Range | 0–60 min (1 min increments) |
| Preheating Time | ≤10 min |
| Standard Sample Well Configuration | Ø28 mm × 25 positions |
| Compliance | Designed for ISO/IEC 17025-compliant sample preparation workflows |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GD25-COD |
| Price | USD 980 (FOB China) |
| Display | Full Chinese LCD Interface |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Time | ≤10 min to Setpoint |
| Digestion Programs | COD, Total Phosphorus, Total Nitrogen, Total Copper, Hexavalent Chromium |
| Timer Range | 1–199 min |
| Timer Accuracy | ±0.1 s at 10 min |
| Sample Capacity | 25 samples per batch |
| Digestion Method | Sealed-Tube Digestion |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GD30 |
| Instrument Type | Graphite Block Digestion System |
| Number of Digestion Positions | 30 |
| Maximum Heating Temperature | 350 °C (optional high-temp upgrade to 450 °C) |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Medium | High-Purity Graphite |
| Power Rating | 1.6 kW |
| Standard Sample Tube Dimensions | Ø30 mm × 55 mm (30 positions) |
| Heating Method | Uniform Surrounding Graphite Block Heating |
| Temperature Uniformity | ±1.5 °C across all positions (20–210 °C) |
| Control System | PID-Based Digital Temperature Controller with Programmable Ramp/Soak Profiles |
| Corrosion Protection | PFA-Coated Lower Housing (ambient models) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | 60 |
| Max Heating Temperature | 450 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Material | Isostatically Pressed High-Purity Graphite |
| Reagent Addition Channels | 2 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 4000 W |
| Temperature Range | Ambient to 350 °C |
| Inter-Well Temperature Uniformity | ±1.0 °C (ambient–250 °C) |
| Well Dimensions | Ø40 mm × 55 mm depth |
| Control Interface | Detachable LCD Digital Display |
| Control Algorithm | PID-Based Closed-Loop Temperature Regulation |
| Overall Dimensions | 500 mm × 350 mm × 180 mm |
| Net Weight | 35 kg |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHP400P |
| Price | USD 850 (FOB) |
| Heating Surface Material | High-Purity Graphite |
| Surface Coating | Optional PFA Coating |
| Max. Temperature (PFA-coated) | 250 °C |
| Max. Temperature (Uncoated) | 450 °C |
| Temperature Control | PID with Digital LCD Controller |
| Uniformity | ±1.5 °C across surface |
| Power Rating | 1600 W |
| Dimensions (W×D×H) | 400 mm × 320 mm × 120 mm |