Applied Biosystems
Filter
Showing all 19 results
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3130xl |
| Instrument Type | First-Generation Sanger Sequencer |
| Category | Capillary Electrophoresis–Based DNA Sequencing System |
| Regulatory Designation | Import-Class Life Science Instrument |
| Vendor Status | Authorized Refurbishment & Distribution Partner |
| Brand | Applied Biosystems |
|---|---|
| Model | 2720 |
| Sample Capacity | 96-well |
| Heating Rate | 2.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.5 °C |
| Operating Temperature Range | 4.0–99.9 °C |
| Heat Lid Temperature | 105 °C |
| Memory Capacity | 100 protocols |
| Tm Calculation | Built-in |
| Power Failure Recovery | Auto-resume |
| NIST-Traceable Calibration | Yes |
| Diagnostic Self-Test | Integrated |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | 2720 |
| Sample Block | Aluminum 0.2 mL 96-well |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.5 °C (35–100 °C) |
| Dimensions (L×W×H) | 36 × 21 × 22 cm |
| Part Number | 4359659 |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 3500/XL |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Category | Imported |
| Distributor Type | Authorized Third-Party Reseller |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7300 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Reaction Volume | 25–100 µL |
| Detection Channels | 4-color fluorescence detection |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7500 |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 48-well formats |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7900HT |
| Instrument Age | 6–8 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per manufacturer specifications |
| Software | SDS 2.4 or later (compatible with Windows-based analysis workstations) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3100 |
| Instrument Type | First-Generation Capillary Electrophoresis Sequencer |
| Sample Throughput | Up to 768 samples per unattended run (2 × 384-well plates or 4 × 96-well plates) |
| Capillary Array | 16-capillary array |
| Excitation Source | Single 488 nm argon-ion laser |
| Detection | Dual-side illumination with grating-based full-spectrum fluorescence detection using CCD camera |
| Voltage Range | Up to 20 kV |
| Operating Temperature | 18–65 °C |
| Dimensions (W×D×H, door closed) | 74 × 54.8 × 81 cm |
| Weight | 130 kg |
| Power Requirement | 200–240 V AC, 50/60 Hz, ≤15 A, 2000 W |
| Environmental Conditions | 15–35 °C ambient, 20–80% non-condensing humidity |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730 |
| Instrument Type | First-Generation Sanger Sequencer |
| Configuration | Refurbished Unit with Full System Validation |
| Compliance | Designed to meet legacy GLP/GMP-relevant operational standards for nucleic acid analysis |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730XL |
| Category | Imported Instrument |
| Condition | Refurbished Unit |
| Sample Throughput | 96-capillary array |
| Read Length | Up to 1,000 bases (typical under standard POP-7 polymer and BigDye Terminator v3.1 chemistry) |
| Data Output Format | AB1 (.ab1), SCF, FASTA, QUAL |
| Base Calling Accuracy | ≥99.99% (Q40+ for >80% of bases in high-quality templates) |
| Run Time | ~2.5 hours per 96-well plate (standard sequencing protocol) |
| Detection System | CCD-based fluorescence detection with four-color laser excitation (488 nm, 532 nm, 595 nm, 635 nm) |
| Capillary Array | 96 × 50 cm fused-silica capillaries with polymer matrix (POP-7 or POP-6) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ArcturusXT™ |
| Laser Types | Near-Infrared (NIR) for LCM + Ultraviolet (UV) for Precision Cutting |
| Microscope Platform | Nikon Eclipse® Ti-E Inverted Research Microscope |
| Sample Compatibility | Glass slides, membrane-coated slides (contact/non-contact), petri dishes, standard glass |
| Software | ArcturusXT™ Control Software + Optional AutoScanXT Image Analysis Module |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ATC |
| Sample Capacity | 96-well and 384-well plates |
| Ramp Rate | 3.5°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Uniformity | ≤0.5°C (20 seconds after reaching 95°C) |
| Compliance | SiLA Rapid Integration™ certified |
| Software Interface | RESTful APIs, preconfigured for Beckman Coulter, Hamilton, and other major automation platforms |
| Brand | Applied Biosystems |
|---|---|
| Model | GeneAmp® 9700 |
| Origin | USA |
| Temperature Accuracy | ±0.25°C (35–100°C) |
| Temperature Range | 4–99°C |
| Ramp Rate | 3.5°C/sec (55–95°C) |
| Block Uniformity | ±0.5°C (35–100°C, 30 sec hold) |
| Heat Lid Temperature | 105°C |
| Display Resolution | 0.1°C (computed sample temperature) |
| Dimensions | 40.6 × 30 × 26 cm |
| Weight | 12.7 kg |
| Sample Formats | Interchangeable blocks — 60-well (0.5 mL), 96-well (0.2 mL), dual 96-well, dual 384-well |
| Software | GeneAmp 9700 Network Software (multi-instrument control) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | MiniAmp |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniAmp Plus |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (30 seconds after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex 2×Flat PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 96-well flat plates (0.2 mL) |
| Heating Rate | 1.6°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Inter-well Temperature Uniformity | <0.5°C (20 sec after reaching 95°C) |
| Module Configuration | Dual independent flat-block thermal modules |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 32-well, 96-well, dual 96-well, dual 384-well, and 24 × 20k Digital PCR Chip modules |
| Ramp Rate | Up to 6.0 °C/s (user-adjustable) |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (measured 20 s after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 4°C/sec |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (measured 30 sec after reaching 95°C) |
| Thermal Control Architecture | VeriFlex™ 3-Zone Independent Peltier Module |
| Interface | Capacitive Touchscreen, USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Compatibility | Thermo Fisher Connect Cloud Platform, compatible with standard .pcr file import/export |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | VeritiPro |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well (0.2 mL) and 384-well (0.02 mL) blocks |
| Heating Rate | 6.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.25°C (at 95°C, measured 30 s after target reached) |
| VeriFlex™ Block | 6 independently controlled thermal zones |
| Thermal Lid | 30–110°C, pressure-adjustable, auto-lift |
| Operating Voltage | 100–240 V, 50–60 Hz |
| Power Consumption | ≤700 W |
| Dimensions (H×W×D) | 21.7 × 24.5 × 46.5 cm |
| Weight | 12.0 kg |
| Environmental Requirements | 15–30°C, 15–80% RH (non-condensing) |