ARALAB
Filter
Showing all 8 results
| Brand | ARALAB |
|---|---|
| Model | FitoClima 1000 ECV45 |
| Temperature Range | −45 °C to +180 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 10–98% RH (at 10–90 °C) |
| Humidity Accuracy | ±0.1% RH |
| Humidity Fluctuation | ±1% RH |
| Humidity Uniformity | ±2% RH |
| Internal Volume | 1000 L |
| Vibration Mode | Horizontal Linear Motion & Vertical Elevating Motion |
| Control System | Integrated Programmable Environmental Controller |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 |
| Internal Volume | 600 L |
| Temperature Range | −5 °C to +45 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±1.0 °C (at setpoint) |
| Temperature Fluctuation | ±0.5 °C (1σ) |
| Humidity Range | 20–95% RH |
| Humidity Uniformity | ±2% RH |
| Humidity Fluctuation | ±0.5% RH (1σ) |
| Shelf Dimensions | 630 mm × 510 mm |
| Shelf Load Capacity | 18 kg per shelf |
| Standard Shelves | 4 stainless steel shelves |
| Max. Shelves | 10 |
| Total Standard Shelf Area | 1.33 m² |
| External Dimensions (H×W×D) | 1980 × 745 × 950 mm |
| Net Weight | 175 kg |
| Power Supply | 1/N/PE, 230 V ±10%, 50 Hz, 16 A |
| Water Supply | Deionized or distilled water, 1–5 bar, conductivity <40 μS/cm |
| Brand | ARALAB |
|---|---|
| Model | FITOCLIMA 600 PLH-R / FITOCLIMA 1200 PLH-R |
| Chamber Type | Vertical Upright Environmental Test Chamber |
| Temperature Range | –5 °C to +45 °C (dark), 2 °C to +45 °C (light on) |
| Temperature Uniformity | < ±2.0 °C (light on) |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 40–80 % RH (light on) |
| Humidity Fluctuation | ±0.5 % RH |
| Humidity Uniformity | < ±2 % RH at 4500 Lux, ±5 % RH at full illumination |
| Visible Light Intensity | Up to 26,000 Lux (cold white LED source) |
| Near-UV Irradiance | 30 W/m² (320–400 nm) |
| Light Control Resolution | Adjustable in 1 % increments |
| Illumination Area per Shelf | 0.14 m² |
| Accumulated Light Dose | 1.2 M·Lux (visible, ≤48 h), 200 W·h/m² (near-UV, ≤7 h) |
| Power Supply | 1/N/PE AC 230 V ±10 %, 50 Hz, 16 A |
| Internal Construction | AISI 304 stainless steel |
| External Casing | Powder-coated galvanized steel |
| Insulation | High-density polyurethane foam |
| Controller | ClimaPlus© 7″ color touchscreen interface with non-volatile memory, Ethernet/Wi-Fi/VLAN/VPN connectivity, 32 programmable profiles (24 steps each), password-protected access, built-in data logger (1-year retention), USB export (read-only), real-time diagnostics, alarm history with timestamped event logging, remote monitoring and control via web browser or mobile app |
| Brand | ARALAB |
|---|---|
| Model | FITOCLIMA 700 SSWT |
| Chamber Internal Volume | 700 L |
| Internal Dimensions (H×W×D) | 900 × 900 × 900 mm |
| External Dimensions (H×W×D) | 1900 × 970 × 1030 mm |
| Water Pan Temperature Range | RT to 90 °C |
| Water Flow Rate | 0–16 L/min (adjustable) |
| Oscillating Pipe Diameter | 400 mm |
| Nozzle Configuration | 7 nozzles, 360° oscillation (±180°), each with variable flow |
| Control Mode | Manual or programmable automatic rotation/spray sequence |
| Safety Feature | Automatic shutdown upon low-water detection |
| Viewing Window | Integrated tempered glass with integrated cleaning mechanism |
| Standards Compliance | DIN 40050-9, IEC 60529 (IPX3, IPX4, IPX4K, IPX9K) |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 PLH / FitoClima 1200 PLH |
| Temperature Range | 5°C to +45°C (±0.1°C) |
| Humidity Range | 40–90% RH (±0.1% RH) |
| Light Intensity | 0–300 µmol/m²·s (up to 21,500 Lux) |
| Internal Volume | 600 L / 1200 L |
| Illumination Type | White LED or Fluorescent Plant-Growth Lighting |
| Temperature Uniformity | ±1.0°C |
| Humidity Uniformity | ±2% RH |
| Airflow Control | 1–100% adjustable (0.3–1 m/s) |
| Compliance | EN 60068-3-5, IEC 61000-6-3, EMC 2004/108/EC, MD 2006/42/CE, LVD 2006/95/CE, EN 14509-CPR 305/2011/EU, EN 13823:2010+A1:2014 |
| Brand | ARALAB |
|---|---|
| Model | FitoClima |
| Temperature Uniformity | ≤ ±1.0°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Uniformity | ≤ ±2.0% RH |
| Humidity Stability | ≤ ±1.0% RH |
| Internal Construction | AISI 304 stainless steel (fully welded) |
| External Construction | Epoxy-coated galvanized steel (RAL 7035) |
| Cooling System | Hermetic compressor-based, low-noise, fluorocarbon-free refrigeration |
| Heating System | Stainless steel annular tubular heaters mounted above fans |
| Air Circulation | Dual variable-frequency fans (top & rear-mounted) with external air exchange ports |
| Safety Systems | Independent high/low temperature & humidity alarms with automatic shutdown and fault-locked operation |
| Controller | Full-color touchscreen interface |
| Compliance | Designed for ISO 14644, ICH Q1–Q5, USP <1151>, and GLP-compliant stability testing environments |
| Brand | Aralab |
|---|---|
| Model | Fitoterm 150 CTE2 |
| Chamber Type | Vertical Dual-Zone (Hot/Cold) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | –75 °C to +60 °C |
| Transfer Time | ≤ 5 s |
| Test Chamber Dimensions (H×W×D) | 410 × 470 × 650 mm |
| External Dimensions (H×W×D) | 2180 × 950 × 1910 mm |
| Load Capacity | 50 kg |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤ ±1.0 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Heating Rate | 0.2 °C/s |
| Weight | 900 kg |
| Cooling System | Compressor-based, CFC-free |
| Control Interface | 4″ color touchscreen with PLC-based controller |
| Programmability | Up to 50 programs, 50 steps each |
| Data Retention | Non-volatile memory with power-loss recovery |
| Safety | Dual independent PT100 Class A sensors per zone, adjustable high/low temperature limits, audible/visual alarms, heated door with dual-seal locking mechanism |
| Communication | Standard RS232 interface |
| Optional Cooling | Water-cooled (external chiller required) or air-cooled configuration |
| Brand | ARALAB |
|---|---|
| Cabinet Type | Upright Walk-in |
| Humidity Range | 35–90 %RH |
| Temperature Stability | ±0.5 °C |
| Compliance | GMP, FDA 21 CFR Part 11 (audit trail capable), ICH Q1–Q5, WHO TRS 992, EU Annex 15, GSP |