Arun Technology Ltd.
Filter
Showing all 28 results
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | High-Resolution CCD Array |
| Spectral Range | 130–700 nm |
| Optical Design | Paschen–Runge Mount with Dual Optical Chambers |
| Cooling | Thermostatically Controlled Enclosure (±0.1 °C) |
| Purge Medium | Argon |
| Compliance | ISO/IEC 17025-ready architecture, GLP/GMP-supporting data integrity features |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | Scientific-grade CMOS Sensor with Active Cooling |
| Wavelength Range | 130–700 nm |
| Element Analysis Time | ≤10 s per measurement |
| Detection Limit | ≤1 ppm for key metallic elements |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, supports GLP/GMP audit trails and ASTM E415, E1086, E1479 methodologies |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark Discharge |
| Detector | Cooled Scientific-Grade A-CMOS Array |
| Wavelength Range | 130–700 nm |
| Optical Configuration | Dual-Optical-Path System |
| Element Coverage | ≥40 elements across Fe, Al, Cu, Ni, Zn, Mg, Co, Ti, Sn, Pb matrices |
| Detection Limit | ≤1 ppm (C, P, S, N with cryogenic cooling) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Calibus 3 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | Not Specified (Nanosecond-Pulsed Solid-State Laser) |
| Wavelength Coverage | 190–700 nm |
| Detector | CMOS Array |
| Optical Stabilization | Active Temperature Control (PID) |
| Gas Purge | Argon (Recirculating System) |
| Quantification Method | Empirical Calibration Curve (Intensity-to-Concentration Mapping) |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Calibus 3S |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | Not Specified (Nanosecond-Pulsed Solid-State Laser) |
| Wavelength Range | 190–700 nm |
| Detector | CMOS Array |
| Optical Architecture | Triple Spectrometer Chambers |
| Cooling | Active PID-Controlled Thermal Stabilization |
| Gas Purge | Recirculating Argon Flush System |
| Operating Temperature Range | −10 °C to +40 °C |
| Analysis Speed | <1 Second per Measurement |
| Safety Certification | Class 1 Laser Product (IEC 60825-1), No X-ray Emission |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Calibus 3S PLUS |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | Not Specified (Nanosecond-Pulsed Solid-State Laser) |
| Wavelength Range | 190–700 nm |
| Detector | CMOS Array |
| Optical Architecture | Triple-Chamber Spectrograph |
| Cooling | Active PID-Controlled Thermal Stabilization (±0.1 °C) |
| Gas Purge | Recirculating Argon Flush System |
| Analysis Speed | <1 Second per Measurement |
| Operating Temperature Range | −10 °C to +40 °C |
| Imaging | Integrated HD Camera with Micro-Region Targeting and Image Logging |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Calibus 5 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Energy | 1 mJ (typical, single-pulse) |
| Wavelength Range | 190–700 nm |
| Detector | CMOS Array |
| Laser Pulse Width | Nanosecond-scale |
| Operating Temperature Range | −10 °C to +40 °C |
| Argon Consumption | ~200 analyses per fill |
| Safety Certification | Class 4 Laser Product (IEC 60825-1), No X-ray Emission |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Calibus 5/9 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | Not Specified (Nanosecond-Pulsed Solid-State Laser) |
| Spectral Range | 190–700 nm |
| Detector | CMOS Array |
| Cooling | Active PID-Controlled Thermal Stabilization |
| Gas Purge | Integrated Argon Circulation System |
| Operating Temperature Range | –10 °C to +40 °C |
| Analysis Time | < 1 s per measurement |
| Elemental Coverage | >30 elements including C, Li, Be, B, Si, Fe, Al, Cu, Ni, Zn, Mg, Ti, Co, Pb, Sn, and others |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Model | Calibus M |
| Instrument Type | Portable / Field-Deployable LIBS Analyzer |
| Optical Range | 190–700 nm |
| Detector | CMOS Array |
| Laser | Q-switched Nanosecond Solid-State, <0.1 °C Thermal Stability Control |
| Pulse Width | Nanosecond |
| Argon Purge | Integrated Recirculating System (≥200 analyses per charge) |
| Operating Temperature | –10 °C to +40 °C |
| Safety | Class 4 Laser (IEC 60825-1 compliant), Interlocked Trigger, Zero X-ray Emission |
| Quantification Method | Empirical Calibration with Multi-Parameter Spectral Correction (Background Subtraction, Matrix Correction, Spectral Drift Compensation) |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CALIBUS Handheld LIBS |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | 400 mJ per pulse (typical, Q-switched Nd:YAG at 1064 nm) |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark Discharge |
| Detector Type | Cooled Scientific-Grade CMOS |
| Wavelength Range | Configurable (UV–Vis, down to ~130 nm) |
| Optical System | Dual-Chamber Paschen–Runge Mount |
| Cooling | Thermoelectric (Peltier) |
| Detection Limit | ≤1 ppm for C, P, S, N, and other metallic/non-metallic elements |
| Stability | Drift-Free Operation (No Recalibration Required Under Normal Conditions) |
| Analysis Time | <10 s per sample |
| Argon Consumption | Reduced by ~67% vs. conventional systems |
| Compliance | Designed for ISO/IEC 17025, ASTM E415, E1086, E3061, and EN 10315 environments |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Type | Cooled Scientific-Grade A-CMOS |
| Focal Length | UV 300 mm, Visible 450 mm |
| Groove Density | UV 3600 lines/mm, Visible 2400 lines/mm |
| Wavelength Range | 130–700 nm |
| Number of Channels | Full CMOS Array (12–15 cm² active area) |
| Cooling | Thermoelectrically Cooled Detector |
| Optical Configuration | Dual Chamber (UV-Dedicated + Visible) |
| Stability | Drift-Free Operation (No Recalibration Required) |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Cooled Scientific CMOS (A-CMOS) |
| Wavelength Range | Configurable (UV–Vis, down to ~130 nm) |
| Optical System | Dual Chamber Design |
| Cooling | Thermoelectric (Peltier) |
| Stability | Drift-Free Operation (No Recalibration Required) |
| Detection Limit | ≤1 ppm for key elements (C, P, S, N, Al, Cu, etc.) |
| Analysis Time | <10 s per sample |
| Argon Consumption | Reduced by ~67% vs. conventional systems |
| Compliance | Designed for ISO/IEC 17025, ASTM E415, E1086, E3061, and USP <730> trace metal analysis workflows |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Type | Cooled Scientific-Grade CMOS |
| Wavelength Range | Configurable (UV–VIS, down to ~130 nm) |
| Optical Design | Dual Chamber |
| Detection Limit | ≤1 ppm for key metallic and non-metallic elements |
| Stability | Drift-Free Operation Without Recalibration |
| Analysis Time | ≤10 s per sample |
| Gas Consumption | Reduced Argon Usage (≈33% of conventional systems) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Charge-Coupled Device (CCD) |
| Spectral Range | Configurable (130–700 nm) |
| Optical Design | Paschen-Runge Mount with Long Focal Length |
| Temperature Control Stability | ±0.1 °C |
| Software Platform | iAPS Intelligent Alloy Identification System, OMVR Calibration Engine, ASR Spark Filtering Algorithm |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Spectral Range | Configurable (130–700 nm) |
| Optical Design | Paschen-Runge Mount with Long Focal Length |
| Gas Environment | Argon-Flushed Optical Chamber |
| Temperature Control Accuracy | ±0.1 °C |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail & GLP/GMP Data Integrity Requirements |
| Sample Handling | Open-Design Spark Stand with Gravity-Driven Electrode, 32 kg Max Load |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Charge-Coupled Device (CCD) |
| Spectral Range | Configurable from 130 nm to 700 nm |
| Optical Design | Paschen–Runge mounting with extended focal length |
| Temperature Control Stability | ±0.1 °C |
| Software Platform | iAPS Intelligent Alloy Identification System, OMVR Optimized Multi-Variable Regression, ASR Aberrant Spark Removal Algorithm |
| Compliance Ready | ASTM E415, ASTM E1086, ISO 11577, ISO 17025-aligned workflows, FDA 21 CFR Part 11 optional audit trail module |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Model | ARTUS 8 U |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | High-Resolution CCD Array |
| Focal Length | 400 mm |
| Grating Line Density | 2400 l/mm (Visible), 3600 l/mm (UV) |
| Wavelength Range | 140–680 nm |
| Spectral Acquisition Mode | Full-Spectrum Direct Reading |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Calibus 3B |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | Not Specified (Nanosecond-Pulsed Solid-State Laser) |
| Wavelength Range | 190–700 nm |
| Detector | CMOS Array |
| Cooling | Active PID-Controlled Thermal Stabilization |
| Gas Purge | Argon Circulation System |
| Operating Temperature Range | −10 °C to +40 °C |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Calibus Al |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Energy | 1 mJ (typical, single-pulse) |
| Laser Pulse Width | Nanosecond-range |
| Wavelength Coverage | 190–700 nm |
| Detection Detector | CMOS-based spectrometer array |
| Operating Temperature Range | –10 °C to +40 °C |
| Argon Consumption | ~5 mL per shot |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HELIUS Series |
| Pricing | Upon Request |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Optical System | Full-Spectrum Holographic Grating |
| Vacuum Requirement | None |
| Wavelength Range | Configurable (typically 130–800 nm) |
| Resolution | High spectral resolution enabled by optimized optical path and CCD pixel density |
| Sample Handling | Open-type spark stand with X-Y motorized sample stage |
| Compliance | Designed to support ISO/IEC 17025, ASTM E415, ASTM E1086, and GB/T 4336 workflows |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Model | MERLIN 4 |
| Excitation | Spark Source |
| Optical System | Paschen-Runge Mount with Holographic Concave Grating |
| Detector | High-Resolution CCD Array |
| Spectral Range | 130–800 nm |
| Resolution | ≤ 10 pm at 200 nm |
| Sample Stage | Motorized X-Y Translation with Open Spark Stand |
| Compliance | ASTM E415, ISO 11577, GB/T 4336 |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Optical Design | Full-Spectrum Holographic Grating |
| Sample Handling | Open-Style Horizontal/Vertical Translational Spark Stand |
| Compliance | Designed for ISO/IEC 17025-aligned laboratories, supports ASTM E415, E1086, and ISO 6892-1 elemental analysis workflows |
| Software | ARUN SpectraSuite with audit trail, user access levels, and data export compliant with FDA 21 CFR Part 11 requirements |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Optical Design | Full-Spectrum Holographic Grating |
| Sample Handling | Open-Type Adjustable Spark Stand with X-Y Translation |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, supports ASTM E415, E1086, and ISO 6892-2 traceable analysis workflows |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PGC Industrial Online Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TDLA-8000 |
| Pricing | Available Upon Request |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UVF Series Total Sulfur Analyzer |
| Price | Upon Request |
