AUTOMESS
Filter
Showing all 4 results
| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-5 |
| Detection Principle | GM tube-based photon (γ/X-ray) dosimetry |
| Energy Range | 45 keV – 3 MeV |
| Dose Rate Range (analog) | 1 µSv/h – 1000 mSv/h |
| Dose Rate Range (digital) | 0.1 µSv/h – 999 mSv/h |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | PTB-certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Interface | RS232 serial port |
| External Probe Support | Yes (up to 100 m cable length) |
| Auto-probe Recognition | Yes |
| Memory | Non-volatile dose storage |
| Alarm Functions | Programmable dose & dose rate thresholds |
| Display | Analog needle + digital LCD with real-time avg/max/accumulated values |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-5 |
| Detection Principle | Ionization Chamber / GM Tube (Internal) + External Probe Compatibility |
| Energy Range | 45 keV – 3 MeV (γ/X-rays) |
| Dose Rate Range (Digital) | 0.1 µSv/h – 999 mSv/h |
| Dose Rate Range (Analog) | 1 µSv/h – 1000 mSv/h |
| Power Supply | IEC 6LR61 9 V battery |
| Certification | PTB-certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Interface | RS232 serial port |
| Max. External Cable Length | 100 m (probe-dependent) |
| Alarm Functions | Programmable dose & dose rate thresholds |
| Data Storage | Non-volatile memory for accumulated dose |
| Auto-probe Recognition | Yes (e.g., “ext 17” display upon connection) |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Alarm Functions | Adjustable Dose & Dose Rate Thresholds |
| Interface | RS232 Serial Port |
| External Probe Support | Up to 100 m cable length (model-dependent) |
| Certification | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | Designed for IEC 60846, IEC 61017, and ISO 4037-3 referenced radiation protection applications |
| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Power Supply | IEC 6LR61 (9 V) Battery |
| Interface | RS232 Serial Port |
| External Probe Cable Length Options | 1.25 m, 3 m, 10 m, 20 m, 75 m, 100 m |
| Compliance | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |