Avantor
Filter
Showing all 7 results
| Brand | Avantor |
|---|---|
| Origin | USA |
| Type | Micro-syringe Pump |
| Flow Rate | 5 pL/min – 200 mL/min |
| Accuracy | ±0.355% |
| Repeatability | ±0.05% |
| Syringe Capacity | 0.5 µL – 140 mL |
| Linear Force | 75 lbs |
| Interface | RS-232, RS-485, USB, 15-pin D-sub |
| Syringe Travel Rate | <190.8 mm/min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | MFLA74905-02 |
| Instrument Type | Micro Syringe Pump |
| Flow Rate | 1.28 pL/min to 88.28 mL/min |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Linear Force | 30 lbf (133 N) |
| Compatible Syringe Volume Range | 0.5 µL – 60 mL |
| Interface | RS-232, RS-485, USB, 15-pin D-sub |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Display | Full-color capacitive touchscreen |
| Mounting | Horizontal or vertical orientation with auto-rotating UI |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | MFLA74900-05 |
| Flow Rate | 0.2 µL/h to 60 mL/h |
| Accuracy | ±0.5% |
| Repeatability | ±0.2% |
| Syringe Capacity | 10 µL–60 mL |
| Linear Force | 20 lbf (9.1 kgf) |
| Power Supply | 230 VAC, 50/60 Hz |
| Warranty | 1 year |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | Traceable TDL/TGW |
| Wireless Protocol | Proprietary Self-Organizing Mesh RF |
| Max Nodes per Gateway | 30 |
| Sampling Interval | 1 min – 24 hr |
| Onboard Memory | 60,000 readings |
| Battery Life | >3 years (TDL), ≥12 hrs (TGW on backup) |
| IP Rating | IP65 (TDL), IP30 (TGW) |
| Operating Temp | −20°C to +60°C (TDL), −5°C to +45°C (TGW) |
| RF Range | >100 m line-of-sight, wall-penetrating |
| Sensor Compatibility | Digital, RS-485, PT100 |
| Data Resilience | Local caching + auto-resume transmission |
| Compliance | Supports 21 CFR Part 11 audit trail readiness, GLP/GMP-aligned data integrity architecture |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | VWRI620-2635 |
| Temperature Range | -200.00 to 105.00 °C |
| Resolution | 0.01 °C |
| Accuracy | ±0.25 °C |
| Sensor Type | Platinum RTD (316 stainless steel sheath) |
| Cable Length | 1 m |
| Data Storage Capacity | 525,600 points |
| Calibration Points | -196 °C, -80 °C, 0 °C, and 100 °C |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | 94460-07 |
| Temperature Range | −50.00 to +70.00 °C |
| Accuracy | ±0.25 °C |
| Resolution | 0.01 °C |
| Probe Type | Patented Bottle Probe |
| Memory Capacity | 525,600 readings |
| Alarm Events | Up to 10 unique events |
| Data Export | USB flash drive (CSV format) |
| Compliance | CDC vaccine storage guidelines |
| Certifications | Traceable® Certificate of Calibration included |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Industrial Display Instrument |
| Model | VWRI620-1980 |
| Channel Count | 1 |
| Display | 6-digit LCD (10.2 mm digit height) |
| Battery | 9 V (1 unit, ~1 year life) |
| Probe Type | Platinum RTD (Pt100 or Pt1000, Class A or AA per IEC 60751) |
| Probe Options | 37804-06 (7" × 0.13" stainless steel stem, 6' cable) / 37804-07 (1" × ¼" PTFE-insulated bullet probe, 10' cable) |
| Temperature Range | –200.000 to +500.000 °C |
| Resolution | 0.1 °C to 0.0001 °C (user-selectable via resolution key) |
| Accuracy | ±0.05 °C or ±0.05% of reading (whichever is greater), valid between –80 °C and +290 °C |
| Data Logging | Internal hourly min/max recorder (24-hour rolling buffer) |
| Response Time | ≤0.33 s for liquids/air/gases/semi-solids (3 updates/sec) |
| Certifications | NIST-traceable Traceable® Certificate included (ISO/IEC 17025-accredited calibration documentation) |
| Physical Dimensions | 89 × 32 × 140 mm |
| Weight | 230 g |
| Accessories | Battery, probe, cable, RS232/USB computer interface, rugged plastic carrying case, Traceable® certificate |