| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | GE AKTA Explorer 100 |
| Operational Age | >10 years |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GE AKTA Explorer 100 Biological Purification System |
| Operational Age | >10 years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% (non-condensing) |
| Power Consumption | 1100 W (instrument: 800 W, PC: 300 W) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C) |
| pH Sensor Range | 0–14 pH (±0.1 pH accuracy, pH 2–12) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | GE AKTA Explorer 100 Protein Purification System |
| Price Range | USD $10,500 – $15,800 (FOB) |
| Operational Age | >10 years |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | GE AKTA Explorer |
| Operational Age | >10 Years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% (non-condensing) |
| Power Consumption | 1100 W (Instrument: 800 W |
| PC | 300 W) |
| UV Detection Range | −6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C) |
| pH Sensor Range | 0–14 pH (±0.1 pH accuracy, pH 2–12) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AKTA Explorer 100 |
| Operational Age | >10 Years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Consumption | 1100 W (system: 800 W, PC: 300 W) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C range) |
| pH Sensor Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12 range) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |