Baseline
Filter
Showing all 15 results
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Baseline 9000 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Configuration | Multi-Component VOC Analyzer |
| Detection Limit | <0.1 ppm (as propane) |
| Measuring Range | 10 ppm–10% (propane) or 10 ppm–50% (methane), factory-configurable per application |
| Operating Sample Temperature | Up to 191°C (376°F) |
| Sample Filtration Requirement | Pre-filtered, non-condensing, particle size <10 µm |
| Display | Graphical LCD with real-time parameter visualization |
| Communication Interfaces | RS-232/RS-485 serial, Ethernet, analog (4–20 mA / 0–10 V), digital I/O, relay outputs |
| Calibration | User-scheduled automatic zero/span calibration |
| Flow Control | Electronic FlowGuard™ system with integrated fuel/air/sample flow regulation, electronic back-pressure regulator, and sample bypass |
| Ignition | Automatic FID ignition sequence |
| Software | 9000 Keeper PC Utility for method storage, configuration upload/download, and firmware management |
| Mounting Options | Benchtop or 19-inch rack-mountable |
| Compliance | Designed for use in environments requiring EPA Method 25A, ASTM D6348, ISO 11843-2, and USP <467> compliant VOC monitoring workflows |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE 9100 |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Baseline 9200 |
| Pricing | Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE piD-TECH eVx |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | eV-NXT 045-110 |
| Price | Upon Request |
| Detection Range | 0–10,000 ppm |
| LOD | 500 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 0.6 mV/ppm |
| Calibration Gas | 2000 ppm Isobutylene (standard) |
| Operating Temperature | –20 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 3.3 V DC nominal |
| Power Consumption | < 80 mW (active mode) |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | eV-NXT 045-111 |
| Detection Range | 0–2,000 ppm |
| LOD | 100 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 2.4 mV/ppm |
| Measurement Condition | 100 ppm |
| Operating Voltage | Low-Voltage DC |
| Power Consumption | Ultra-Low |
| Intrinsic Safety Rating | Certified |
| Onboard Fault Detection | Yes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-112 |
| Detection Range | 0–200 ppm |
| LOD | 10 ppb |
| T90 | < 3.5 s |
| Typical Sensitivity | 12 mV/ppm |
| Operating Condition | 100 ppm |
| Power Requirements | Low-voltage, low-power design |
| Compliance | Intrinsically Safe (IS) certified |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-113 |
| Detection Range | 0–20 ppm |
| LOD | 1.0 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 118 mV/ppm |
| Measurement Condition | 10 ppm |
| Operating Voltage | Low-Voltage DC |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-114 |
| Detection Range | 4 ppm |
| LOD | 0.5 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 545 mV/ppm |
| Measurement Condition | 1 ppm |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE PID-TECH eV-NXT |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-010 |
| Pricing | Available Upon Request |
| Certification | UL, CAN/CSA C22.2 No. 60079-0, ATEX II 2G Ex d [ia] IIC T4 Ga, IECEx Ex d [ia] IIC T4 Ga |
| Detection Range | 0–10,000 ppm isobutylene equivalent |
| Minimum Detectable Quantity (MDQ) | 500 ppb (isobutylene) |
| T90 Response Time | < 2 s (typical) |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Output Signal | 0–5 V DC analog |
| Power Supply | 5.0 V ±0.1 V DC |
| Ingress Protection | IP67-rated housing |
| Filter Configuration | Dual-stage particulate & hydrophobic membrane filter |
| Temperature Drift | < 0.05% FS/°C |
| Humidity Compensation | Electrode-based active suppression |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-011 |
| Price | Upon Request |
| Detection Range | 2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 100 ppb |
| T90 Response Time | < 2 s (typical) |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Design | Intrinsically Safe, 4-Series Compatible Form Factor |
| Lamp Lifetime | Extended Operational Life |
| Temperature Sensitivity | Negligible |
| Humidity Compensation | Electrode-Based Suppression |
| Filtering | Dual-Stage Particle Protection |
| Signal Stability | Internal Linear Regulator Circuitry |
| Maintenance | Field-Serviceable, Cleanable Electrodes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-013 |
| Price | Upon Request |
| Detection Range | 20 ppm |
| Minimum Detectable Quantity (MDQ) | 1.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Housing Color | Yellow |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Sensor Architecture | 4-Series Compatible |
| Lamp Type | Long-Life UV Lamp (10.6 eV) |
| Internal Regulation | Dual Linear Voltage Regulators |
| Filtration | Dual-Stage Particle Filter |
| Humidity Compensation | Electrode-Based Suppression |
| Thermal Drift | Negligible |
| Maintenance | Field-Serviceable & Cleanable |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-014 |
| Pricing | Available Upon Request |
| Detection Range | 2 ppm |
| Minimum Detectable Quantity (MDQ) | 0.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Certification | UL, CAN/CSA C/US, ATEX II 1G, IECEx Ex ia IIC T4 Ga |
| Sensor Architecture | 4-Series Compatible Form Factor |
| Lamp Life | > 12,000 hours |
| Operating Temperature Range | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based suppression |
| Filtering | Dual-stage particulate protection |
| Power Supply | Internal linear regulation for signal stability |
| Maintenance | Field-serviceable, cleanable electrode assembly |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ |
| Detection Range | 0–2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 10 ppb |
| T90 Response Time | < 2 s (typical) |
| Certifications | UL, CAN/CSA C22.2 No. 152, ATEX II 2G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga |
| Intrinsic Safety Design | Yes |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based humidity suppression |
| Dual-Stage Particle Filtration | Integrated |
| Signal Stability | Internal linear voltage regulation |
| Structural Compatibility | 4-Series electrochemical sensor footprint |