BCC
Filter
Showing all 24 results
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | BKS-3000 |
| Instrument Type | Flue Gas CEMS |
| Accuracy | ≤±1% FS/24h |
| Repeatability | ≤±1% FS/24h |
| Response Time | ≤10 s |
| Stability (Zero/Scale Drift) | ≤±1% FS/24h (gaseous), negligible drift (particulate) |
| Measured Parameters | SO₂, NOₓ (NO, NO₂, N₂O), CO, CO₂, SO₃, CH₄, O₂, HCl, NH₃, HF, H₂S, H₂O, particulate matter (PM) |
| Detection Methods | Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), UV Differential Optical Absorption Spectroscopy (UV-DOAS), Electrochemical (O₂), Optical Scattering (PM) |
| Output Interfaces | RS232, RS485, 4–20 mA, Ethernet, 4G/5G cellular |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KPV-2000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | Temperature, Pressure, Velocity |
| Temperature Range | 0–500 °C (customizable up to 1100 °C) |
| Pressure Range | −8 to +8 kPa |
| Velocity Range | 5–40 m/s |
| Measurement Methods | Pt100 resistance thermometer (temperature), piezoresistive pressure transducer (pressure), Pitot tube differential pressure method (velocity) |
| Accuracy | ±2% relative error |
| Power Consumption | < 0.04 kVA |
| Output Signal | 4–20 mA analog |
| Environmental Rating | Rated for continuous operation at ambient housing temperatures up to 1100 °C |
| Additional Feature | Integrated automatic purge system |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KSD-1000 |
| Instrument Type | Relative Humidity (RH) Sensor |
| Measurement Range | 0–100% RH |
| Accuracy | ±1.5% RH |
| Resolution | 1% RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Power Supply | 220 VAC, 50 Hz |
| Sensing Principle | Polymer Thin-Film Capacitive |
| Output Signal | 4–20 mA DC |
| Enclosure Rating | IP65 (Dust-Resistant & Corrosion-Resistant) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KSP-L-1000 (Extractive) |
| Measurement Principle | Laser Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–5–200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±2% FS |
| Relative Error | ≤±2% FS |
| Zero Drift | ≤±2% FS/24h |
| Span Drift | ≤±2% FS/24h |
| Detection Limit | 0.01 mg/m³ |
| Sampling Flow Rate | Up to 250 L/min |
| Heating Temperature | Full-Path Heated Sampling Line (Typical Setpoint: 120–180°C) |
| Calibration | Automated Zero & Span Calibration |
| Carrier Gas | Integrated Air Pump (Frost-Resistant Design) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000 |
| Sensor Type | Paramagnetic |
| O₂ Range | 0–100% vol |
| O₂ Resolution | 0.01% vol |
| O₂ Accuracy | ±1% FS |
| CO Range | 0–10 ppm |
| CO Resolution | 0.01 ppm |
| CO Accuracy | ±2% FS |
| CO₂ Range | 0–500 ppm |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Accuracy | ±2% FS |
| Dew Point Temperature Range | −50 to +100 °C |
| Dew Point Resolution | 0.1 °C |
| Dew Point Accuracy | ±0.5 °C |
| Barometric Pressure Range | 50–110 kPa |
| Pressure Resolution | 0.01 kPa |
| Pressure Accuracy | ±0.5 kPa |
| Zero Drift | ≤2% FS |
| Span Drift | ≤±2% FS |
| Data Storage | Scheduled auto-storage |
| Analog Output | 4–20 mA |
| Digital Interfaces | RS232 / RS485 / USB / Ethernet |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Accuracy | ±1 ppm or ±2% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±2% FS/24 h |
| Response Time (T90) | ≤90 s |
| Sampling Method | Extractive |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Enclosure Rating | IP65 |
| Explosion Protection | Ex d IIB T4 Gb |
| Power Supply | 220 V AC |
| Brand | BCC |
|---|---|
| Model | MGA-3000 |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Configuration | Fixed-Mount |
| Detection Range | 0–10 / 50 / 100 / 500 / 1000 ppm to 100% vol (gas-dependent, customizable) |
| Sensitivity | 1 ppb |
| Response Time | T90 ≤ 60 s |
| Repeatability | ≤ ±1 % FS |
| Accuracy | ≤ ±2 % FS |
| Zero Drift | ≤ ±1 % FS / 24 h |
| Detection Limit | 0.1–1 ppm (varies by target gas) |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Enclosure Options | 19″ rack-mount, benchtop, portable |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000Ex |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Fixed-Mount Industrial Analyzer |
| Detection Range | 1 ppb to 100% vol |
| Sensitivity | 1 ppb (for select gases) |
| Response Time | T90 ≤ 60 s |
| Repeatability | ≤ ±1% FS |
| Accuracy | ±0.1–2% FS (gas-dependent) |
| Zero/Full-Scale Auto-Calibration | Yes |
| Drift | ≤ ±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP) |
| Enclosure Options | 19" rack-mount, benchtop |
| Certified Protection | Ex d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-3000P (Ammonia-Specific) |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Portable Multicomponent Gas Analyzer |
| Measurement Range | 1 ppb to 100% vol NH₃ (customizable) |
| Sensitivity | 1 ppb (NH₃) |
| Response Time | T₉₀ ≤ 20 s |
| Repeatability | ±1–2% FS |
| Zero/ Span Drift | ≤ ±1% FS / 24 h |
| Power Consumption | < 100 W |
| Output Interfaces | 4–20 mA, RS232 / RS485, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Model | MGA-3000P |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Portable |
| Detection Range | 0.1 ppm to 100% vol |
| Sensitivity | 0.01 ppm |
| Response Time (T90) | ≤30 s |
| Repeatability | ±1–2% FS |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Detection Limits | 0.1–1 ppm (gas-dependent) |
| Power Consumption | <100 W |
| Data Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Sample Handling | Dual-mode (cold-dry and hot-wet) |
| Gas Selectivity | Enhanced via Gas Correlation Filtering (GCF) |
| Simultaneous Channels | Up to 7 gas components |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000 |
| Sensor Type | Paramagnetic |
| Measurement Range | 80/98–99.99% O₂ (user-selectable span) |
| Accuracy | ±0.1% FS |
| Repeatability | ±0.01% FS |
| Resolution | 0.01% O₂ |
| Response Time | T₉₀ ≤ 15 s |
| Sample Flow Rate | 400 ± 50 mL/min |
| Operating Temperature | –15 °C to +45 °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Data Storage | Scheduled automatic logging |
| Output Interfaces | 4–20 mA analog, RS232 / RS485 serial, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MGA-6000 |
| Sampling Method | Extractive |
| Power Supply | 220 V AC |
| Explosion Protection | Ex d IIB T4 |
| Ingress Protection | IP65 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analytes | Ethyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester |
| Measurement Range | 0–100 ppm |
| Response Time (T90) | ≤60 s |
| Accuracy | ±1 ppm or ±1% of reading (whichever is greater) |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS-232 / RS-485, USB, Ethernet |
| Brand | BCC |
|---|---|
| Model | MGA-6000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Range | 0–1 ppm to 0–100% (selectable, multi-range auto-switching) |
| Sensitivity | 1 ppb (gas-dependent) |
| Response Time | T90 ≤ 20 s |
| Repeatability | ≤ ±1% FS |
| Zero/Scale Drift | ≤ ±1% FS / 24 h |
| Operating Temperature Stability | Active thermal control with proprietary temperature management |
| Enclosure Options | 19" rack-mount, benchtop, and portable configurations |
| Data Interfaces | 4–20 mA analog output, RS232 / RS485 serial, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MGA-6000 |
| Linearity Error | ≤±2% FS |
| Repeatability | ≤1% |
| Zero/ Span Drift | ≤±1% FS / 24 h |
| Response Time (T₉₀) | ≤20 s |
| Measurement Range | 0–50 ppm (extendable to 0–100 ppm) |
| Resolution | 0.1 ppm |
| Output Interfaces | 4–20 mA, RS232 / RS485, USB, Ethernet |
| Brand | BCC |
|---|---|
| Model | MGA-6000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gases | Formaldehyde (HCHO), Formic Acid (HCOOH) |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ 1% FS |
| Zero/ Span Drift | ≤ ±1% FS / 24 h |
| Response Time (T90) | ≤ 20 s |
| Detection Limit | 1 ppb – 1 ppm (gas-dependent) |
| Measurement Ranges | 0–1, 0–10, 0–50, 0–100, 0–500, 0–1000 ppm, up to 100% vol (customizable) |
| Enclosure Options | 19" rack-mount, benchtop, portable |
| Output Interfaces | 4–20 mA, RS232 / RS485, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Model | MGA-6000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time (T90) | ≤20 s |
| Measurement Range | 0–8000 mg/Nm³ |
| Minimum Detectable Range | 0–500 mg/Nm³ |
| Resolution | 0.1 mg/Nm³ |
| Zero Drift | ≤±1.5% FS |
| Span Drift | ≤±1.5% FS |
| Linearity Error | ≤±2% |
| Operating Temperature | 10–30 °C |
| Power Consumption | ≤120 W |
| Output Signals | 4–20 mA, RS232/RS485, USB, Ethernet |
| Alarm Outputs | High/Low H₂S concentration, sample flow fault (dry contact) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000 |
| Sensor Type | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measurement Range | 0–3000 ppb |
| Accuracy | ±0.1% FS |
| Response Time | 1–60 s |
| Repeatability | ≤ ±0.5% |
| Resolution | 1 ppb |
| Detection Limit (LDL) | 10 ppb |
| Drift | ≤ ±1% / 24 h |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet, 4G, 5G |
| Enclosure | 19″ rack-mountable & desktop form factor |
| Data Storage | Industrial-grade SSD with ≥5 years local data retention |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000Ex |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Fixed-mount |
| Detection Range | ppb to 100% vol |
| Sensitivity | 1 ppb |
| Response Time | T90 ≤ 20 s |
| Repeatability | ≤ ±1% FS |
| Accuracy | 0.1–2% FS |
| Drift | ≤ ±1% FS / 24 h |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP) |
| Auto-Calibration | Zero & Span |
| Certified Protection | Ex d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000P |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Portable |
| Detection Range | ppb to 100% (gas-dependent) |
| Sensitivity | 1 ppb |
| Response Time (T90) | ≤20 s |
| Repeatability | 1–2% FS |
| Drift | ≤±1% / 24 h |
| Power Consumption | <100 W |
| Detection Limits | 1 ppb – 1 ppm (varies by target gas) |
| Data Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Brand | BCC |
|---|---|
| Model | MGA-8000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) with Off-Axis ICOS |
| Detection Range | 0–1 / 10 / 50 / 100 / 500 ppm (selectable per gas) |
| Detection Limit | <1 ppb (gas-dependent) |
| Response Time (T90) | ≤20 s |
| Repeatability | ≤±0.1% FS |
| Drift | ≤±1% FS / 24 h |
| Temperature Control Stability | ±0.005 °C |
| Pressure Control Stability | ±0.0002 atm |
| Sample Temperature Range | −10 to +50 °C |
| Output Interfaces | 4–20 mA, RS-232 / RS-485 (Modbus RTU), USB, Ethernet |
| Power Supply | 200–240 VAC, 50/60 Hz |
| Enclosure Options | 19″ rack-mount, benchtop, portable |
| Brand | BCC |
|---|---|
| Model | MGA-6000 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gases | Acetylene (C₂H₂) and Ethylene (C₂H₄) |
| Linearity Error | ≤ ±1% FS |
| Repeatability | ≤ 1% FS |
| Drift | ≤ ±1% FS/24 h |
| Response Time (T90) | ≤ 20 s |
| Detection Limit | 1 ppb – 1 ppm |
| Range Options | 0–1, 0–10, 0–50, 0–100, 0–500, 0–1000 ppm up to 100% vol (customizable) |
| Enclosure Types | 19″ rack-mount, benchtop, portable |
| Output Interfaces | 4–20 mA, RS232/RS485, USB, Ethernet |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA-6000 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Range | 80/98–99.99% O₂ (user-selectable sub-ranges) |
| Accuracy | ±0.1% FS |
| Repeatability | ±0.01% FS |
| Stability | ±0.02% FS |
| Response Time | T₉₀ ≤ 15 s |
| Resolution | 0.01% O₂ |
| Sample Flow Rate | 400 ± 50 mL/min |
| Operating Temperature | −15 °C to +45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Output Interfaces | 4–20 mA analog, RS232 / RS485 serial, USB, Ethernet (TCP/IP) |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA6000 |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Fixed-Installation Multicomponent Gas Analyzer |
| Measurement Target | H₂O vapor in gas streams |
| Detection Range | 0–10 / 50 / 100 / 500 / 1000 ppm up to % level (configurable) |
| Limit of Detection (LOD) | 10 ppb |
| Response Time (T90) | ≤20 s |
| Repeatability | ≤±1% FS |
| Output Interfaces | RS-485, Ethernet (TCP/IP) for DCS integration |
| Data Storage | Embedded SSD with 5-year local retention |
| Design | Modular, maintenance-free architecture |
| Consumables | None |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | MGA6000 |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Type | Fixed-mount analyzer |
| Measurement Range | 0–1000 ppm H₂O |
| Limit of Detection (LOD) | 10 ppb H₂O |
| Response Time (T90) | ≤20 s |
| Repeatability | ≤±1% FS |
| Output Interfaces | RS-485, Ethernet (TCP/IP) |
| Data Storage | Embedded SSD (5-year capacity) |
| Design | Modular, maintenance-free architecture |
| Compliance | Designed for continuous industrial process monitoring per ISO 8573-3 and ASTM D7217 |