Beifen Ruili
Filter
Showing 1–30 of 33 results
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | AES-8000 Series |
| Instrument Type | Benchtop Direct-Reading Spectrometer |
| Excitation Source | AC/DC Arc |
| Detector | UV-Sensitive CMOS Array |
| Focal Length | 600 mm |
| Grating Grooves | 2400 lines/mm |
| Wavelength Range | 230–340 nm |
| Spectral Coverage | Full-Spectrum Acquisition |
| Optical Design | Vertical Symmetric Ebert-Fastie |
| Reciprocal Linear Dispersion | 0.64 nm/mm (1st order) |
| Theoretical Spectral Resolution | 0.003 nm @ 300 nm |
| Spectrometer Chamber Temperature Control | 35 °C ± 0.1 °C |
| Arc Current Range | 2–20 A (AC), 2–15 A (DC) |
| Dimensions (L×W×H) | 1500 × 820 × 650 mm |
| Weight | ~180 kg |
| Operating Environment | 15–30 °C, RH < 80 % |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | AF-640A |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au (12 elements) |
| Relative Standard Deviation (RSD) | <1% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Bi, Se, Te, Pb, Sn: <0.01 µg/L |
| Hg, Cd | <0.001 µg/L |
| Ge | <0.05 µg/L |
| Zn | <1.0 µg/L |
| Au | <3.0 µg/L |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | AF3000 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au, Ag, Co, Cu, Ni |
| Relative Standard Deviation (RSD) | < 0.7% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Sb, Bi, Se, Te, Pb, Sn < 0.01 µg/L |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | AF3000 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au, Ag, Co, Cu, Ni (16 elements) |
| Relative Standard Deviation (RSD) | < 0.7% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Sb, Bi, Se, Te, Pb, Sn < 0.01 µg/L |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | FR60 |
| Instrument Type | Portable Hybrid FTIR-Raman Spectrometer |
| IR Wavenumber Range | 4200–650 cm⁻¹ |
| Raman Wavenumber Range | 175–2800 cm⁻¹ |
| IR Resolution | < 4 cm⁻¹ |
| Raman Resolution | < 10 cm⁻¹ |
| Scan Speed | Full-spectrum acquisition in ≤ 5 seconds |
| Signal-to-Noise Ratio (SNR) | > 2000:1 (IR, 100 scans) |
| Wavenumber Accuracy | < ±0.1 cm⁻¹ at 2000 cm⁻¹ |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Field | General-Purpose |
| Mass Range | 10–2250 Da |
| Ionization Sources | Dual ESI/APCI |
| Collision Cell | Curved RF-only Quadrupole Design |
| Gas System | Counter-Flow Curtain Gas Configuration |
| Software | Integrated Intelligent Tuning, Calibration, Method Optimization & Reporting Engine |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | HMS7680 |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | General-Purpose |
| Ionization Sources | ESI and APCI |
| IM Resolution Modes | 3 Adjustable Settings |
| Mass Analyzer Configuration | Quadrupole + Orthogonal TOF |
| Collision Cell | Axial DC Voltage Gradient CID with Tunable Collision Gas |
| Temperature Control | Water-Cooled, Thermally Stabilized Flight Tube with Intelligent Compensation |
| Acquisition Mode | 4D Full-Spectrum Simultaneous Detection |
| Software Features | Automated Tuning, Real-Time Mass Calibration, Method Optimization, and Integrated Data Processing & Reporting |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | MAS-100 |
| Pricing | Upon Request |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | OILA-I |
| Instrument Type | Benchtop |
| Excitation Method | Arc |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Grating Grooves | 2400 lines/mm |
| Wavelength Range | 201–810 nm |
| Detection Mode | Full-Spectrum Simultaneous Acquisition |
| Argon Consumption | None |
| Detector Resolution | High-Density CMOS Array with Pixel-Level Spectral Sampling |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | PAF-1100 |
| Instrument Type | Single-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au, Cu, Ag, Co, Ni |
| Detection Limits | As ≤ 0.06 µg/L, Hg (Cold Vapor Method) ≤ 0.006 µg/L |
| Relative Standard Deviation (RSD) | As ≤ 1.5%, Hg (Cold Vapor Method) ≤ 1.5% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Linearity (r) | ≥ 0.999 for As (0.5–50 µg/L) and Hg (0.05–5 µg/L) |
| Drift | ≤ 2% over 30 min |
| Noise | ≤ 2% over 30 min |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-2110 |
| Instrument Type | Dedicated Gas Chromatograph for Dissolved Gas Analysis (DGA) in Transformer Oil |
| Compliance | Designed to meet GB/T 17623–2017, DL/T 703–2015, and IEC 60567 requirements |
| Interface | USB 2.0 |
| Data Acquisition | Integrated with Transformer Oil DGA-Specific Chromatography Workstation |
| Injection System | Manual syringe injection with micro-switch trigger activation |
| Gas Control | Equipped with digital pressure and mass flow sensors for carrier gas (N₂, H₂, or Ar) and detector gases |
| Detector Configuration | Dual-TCD (Thermal Conductivity Detector) or TCD+FID (optional) |
| Column | Pre-packed stainless-steel capillary or packed column optimized for C₁–C₅ hydrocarbons and CO/CO₂ separation |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-2120 |
| Temperature Control Range | 20–400 °C above ambient |
| Ramp Rate | 0.5–35 °C/min |
| Cool-down Time | <5 min (250 °C → 50 °C) |
| Carrier Gas Pressure Range & Control | 0–0.8 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.8 MPa |
| Detection Limits | H₂ ≤5 ppm, CO ≤0.5 ppm, O₂/N₂ ≤0.05 vol%, CH₄/CO₂/C₂H₄/C₂H₆/C₂H₂ ≤0.1 ppm |
| Total Analysis Time | ≤7 min (single injection, 9-component full profile) |
| Simultaneous Active Detectors | 3 (TCD + dual FID) |
| Flow Sensors | 4-channel digital gas flow monitoring |
| Valve Configuration | High-reliability imported 10-port rotary valve |
| Explosion Risk Assessment | Real-time calculation per GB/T 20964–2007 and AQ 1018–2006 |
| Compliance | Designed for GLP-compliant coal mine safety labs |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-3420A |
| Temperature Control Range | Ambient +12 °C to 400 °C |
| Maximum Oven Ramp Rate | >35 °C/min (100 °C to 200 °C in <3 min) |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Compatible Detectors | TCD, FID, ECD, FPD, TSD |
| Injection Systems | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 pre-programmed methods |
| Diagnostic Capability | Real-time self-diagnostic with fault localization |
| Safety Protections | TCD carrier-gas failure protection, overtemperature shutdown, FPD light-leak detection |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP-3500 |
| Price Range | USD 14,000–21,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Maximum Ramp Rate | 50°C/min |
| Carrier Gas Flow Control | 0–1000 mL/min (H₂) |
| Carrier Gas Pressure Control | 0–100 psi |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min (H₂) |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | SP-3510 |
| Price Range | USD 14,000–21,000 (FOB Beijing) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5 °C above ambient to 450 °C |
| Maximum Ramp Rate | 50 °C/min |
| Cooling Capability | Forced-air cooling (no cryogenic option) |
| Carrier Gas Flow Control Range | 0–1000 mL/min (H₂) |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min (H₂) |
| Heating Zones | 9 independent temperature-controlled zones |
| Simultaneous Inlets/Detectors | Up to 3 inlets and 3 detectors operational concurrently |
| Detector Options | FID, TCD, ECD, FPD, TSD, AFD |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-5220 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Regulatory Compliance | CE-marked per EN 61010-1, IEC 61326-1 (EMC), ISO/IEC 17025-compatible operation |
| Control System | Linux-based embedded platform with Ethernet and USB 2.0 interfaces |
| Pressure Control Accuracy | ±0.001 psi (EPC) |
| Temperature Program Reproducibility | ±0.5% (RSD) |
| MTBF | >12,000 hours |
| Safety Certification | UL 61010-1 / GB 4793.1 compliant |
| Electromagnetic Compatibility | Tested to IEC 61326-1 Class A |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP3400 |
| Temperature Control Range | Ambient +12 °C to 420 °C |
| Maximum Oven Ramp Rate | >33 °C/min (100 °C to 200 °C in <3 min) |
| Injector Max Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 methods |
| Compliance | Designed to meet ISO/IEC 17025 operational prerequisites for routine GC analysis |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SY-9100 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical use |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 42 MPa |
| Flow Precision | <0.1% RSD |
| Sample Tray Capacity | 96 positions (1.5 mL vials) |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SY9230 |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion and Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate Accuracy | 0.1–5.0 mL/min |
| Max Operating Pressure | 35 MPa |
| Column Oven Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Stability | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Fluidic Path Material | Full-PEEK (Polyetheretherketone) |
| Eluent Generation | On-Demand Electrolytic Eluent Generator (EG) with Water-Only Input |
| Degassing | Integrated Low-Pressure Membrane Degasser + Gas-Liquid Separator |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection, Eluent Reservoir Level Sensing, Auto-Shutdown Protocol |
| Consumables Monitoring | Column & Suppressor Usage Tracking with Auto-Recognition of New Units |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | UV-1601 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (5-step selectable) |
| Stray Light | ≤0.1% T (at 220 nm with NaI |
| Auto Wavelength Scanning | Yes |
| Dimensions | 630 × 470 × 210 mm |
| Weight | 26 kg |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Power Consumption | 180 W |
| Interface | USB port, optional PC control, printer output |
| Data Retention | Non-volatile memory for parameters and measurements |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | UV-1801 |
| Optical System | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 1.0, 2.0, or 5.0 nm (user-selectable) |
| Stray Light | ≤0.05% T (at 220 nm with NaI solution |
| Display | 6-inch high-brightness blue LCD |
| Light Sources | Imported deuterium lamp and tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Power Consumption | 140 W |
| Dimensions (W×D×H) | 530 × 420 × 205 mm |
| Net Weight | 18 kg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | UV-2200 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.25 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 nm (6-step selectable) |
| Stray Light | ≤0.001% T (at 220 nm using NaI solution |
| Wavelength Scanning Resolution | 0.02 nm minimum sampling interval |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 400 W |
| Dimensions (W×D×H) | 730 × 530 × 230 mm |
| Net Weight | 40 kg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | UV-2601 |
| Optical Design | Dual-beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 0.5–5.0 nm (5 selectable steps) |
| Stray Light | ≤0.1% T (at 220 nm using NaI |
| Display | 6-inch high-brightness blue LCD |
| Light Sources | Socket-type deuterium lamp and tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 630 × 470 × 210 mm |
| Net Weight | 26 kg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | UV-9600 |
| Optical System | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2.0 nm |
| Spectral Bandwidth | 1.0, 2.0, 4.0, 5.0 nm (selectable) |
| Stray Light | ≤0.05% T (at 220 nm with NaI |
| Display | 16×2 LCD |
| Light Sources | Plug-in deuterium lamp (optional), plug-in tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Power Consumption | 120 W |
| Dimensions (W×D×H) | 530 × 410 × 210 mm |
| Net Weight | 16 kg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | VIS-723N |
| Optical System | Single-beam |
| Detector | Silicon photodiode array |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 1.0, 2.0, or 5.0 nm (user-selectable fixed settings) |
| Stray Light | ≤0.05% T (at 220 nm using NaI solution |
| Wavelength Scanning | Motorized automatic wavelength drive |
| Dimensions | 530 × 420 × 205 mm |
| Weight | 18 kg |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Power Consumption | 140 W |
| Interface Options | RS-232 (RS-485 and USB available on request) |
| Data Storage | Non-volatile memory for method parameters and measurement results |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-200 |
| Instrument Type | Dual-mode Flame/Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Flame mode — Cu: 0.04 µg/mL per 1% absorption |
| Graphite furnace mode — Cd | ≤0.9 pg |
| Precision (RSD) | Flame mode ≤0.9% |
| Detection Limit | Flame mode — Cu: 0.007 µg/mL |
| Graphite furnace mode — Cd | ≤4.0 pg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-210 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Flame mode — Cu: 0.04 µg/mL per 1% absorption |
| Graphite furnace mode — Cd | ≤0.9 pg |
| Precision (RSD) | Flame mode ≤0.9% |
| Detection Limit | Flame mode — Cu: 0.007 µg/mL |
| Graphite furnace mode — Cd | ≤4.0 pg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-220A |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-absorption Method |
| Spectral Bandwidth | 0.2 nm ± 0.02 nm (at 0.2 nm setting) |
| Sensitivity | Flame mode — Cu ≤0.03 µg/mL/1% |
| Precision (RSD) | Flame mode — Cu ≤0.5% |
| Detection Limit | Flame mode — Cu ≤0.003 µg/mL |
| Baseline Stability | ≤0.002 absorbance units/30 min |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-810 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy < 36% |
| Sensitivity | Flame mode — Cu 0.13 µg/mL per 1% absorption |
| Repeatability (RSD) | Flame RSD ≤ 0.9% |
| Detection Limit | Flame — Cu 0.010 µg/mL |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-910 |
| Optical System | Single-beam |
| Detector Type | Solid-state CCD detector |
| Atomizer Type | Resistive-heated filament atomizer |
| Power Consumption | ~6% of conventional graphite furnace systems |
| Dimensions (H×W×D) | 335 mm × 610 mm × 230 mm |
| Weight | 18 kg |
| Compliance | Designed for field-deployable environmental monitoring per ISO 8288, EPA Method 7000B principles |
| Software | Embedded acquisition and quantification interface with calibration curve generation and QC flagging |