BINDER
Filter
Showing 31–51 of 51 results
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB Series |
| Temperature Range | 0 °C to +70 °C |
| Temperature Uniformity at 37 °C | ±0.2 K |
| Temperature Fluctuation at 37 °C | ±0.1 K (KB 130 and larger) |
| Recovery Time after 30-sec Door Opening at 37 °C | 3 min |
| Internal Volume | 63 L to 1070 L |
| Power Consumption | 0.9 kW to 1.5 kW |
| Refrigerant | R-600a |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Imported |
| Model | KB 1060 |
| Cooling Method | Compressor-based refrigeration |
| Heating Method | Water-jacketed heating |
| Temperature Range | 0 °C to +70 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C |
| Chamber Volume | 1070 L |
| External Dimensions (W×H×D) | 1285 mm × 1951 mm × 1175 mm |
| Refrigerant | R-600a |
| Insulation | HIT multi-layer jacket technology |
| Interior | Electropolished stainless steel (AISI 304) |
| Inner Door | Safety glass with metal oxide coating |
| Shelving | 2 adjustable stainless steel shelves |
| Data Interface | Ethernet, USB |
| Compliance | DIN 12880 Class 3.3 temperature safety device, GLP-compliant data logging |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF PRO |
| Temperature Range | −20 to 100 °C |
| Humidity Range | 10–98 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.2 K (KBF PRO 130 & 260), ±0.3 K (KBF PRO 470–1600) |
| Temp. Stability (25 °C / 60 % RH) | ±0.1 K |
| Humidity Stability (25 °C / 60 % RH) | ±1 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1 min |
| Recovery Time (40 °C / 75 % RH, 30 s door open) | 3–5 min |
| Internal Volume | 127–1610 L |
| Power Consumption | 1.6–1.9 kW |
| Refrigerant | R-290 (eco-friendly hydrocarbon) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF Series |
| Type | Benchtop Environmental Test Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–80 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.1–0.4 K |
| Humidity Stability (25 °C / 60 % RH) | ±1.5 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1–3 min |
| Power Consumption | 1.3–1.7 kW |
| Internal Volume | 127–1610 L |
| Refrigerant | R-600a |
| Compliance | DIN 12880, ICH Q1–Q5, GLP/GMP-ready |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF-S ECO Solid.Line |
| Temperature Range (with Humidification) | 0 °C to +70 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity (25 °C / 60 % RH) | ±0.1 K |
| Temperature Fluctuation (40 °C / 75 % RH) | ±0.1 K |
| Humidity Fluctuation (40 °C / 75 % RH) | ±0.3 % RH |
| Recovery Time after 30-sec Door Opening (40 °C / 75 % RH) | 11–17 min |
| Internal Volume Options | 247 L, 400 L, 700 L, 1020 L |
| Power Consumption (25 °C / 60 % RH) | 55–90 Wh/h |
| Noise Level | 45–49 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Type | Upright |
| Model Families | KBF, KBF P, KBF LQC, KMF |
| Temperature Range (dry) | 0–70 °C |
| Temperature Range (humidified) | 10–70 °C |
| Humidity Range | 10–80 % RH |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KT53 / KT115 / KT170 |
| Temperature Range | 4 °C to 100 °C |
| Internal Volume | 53 L / 102 L / 163 L |
| External Dimensions (W×H×D, mm) | 660×635×630 / 860×715×655 / 860×1025×655 |
| Internal Dimensions (W×H×D, mm) | 400×400×334 / 600×455×355 / 600×765×355 |
| Net Weight | 63 kg / 83 kg / 102 kg |
| Inner Door | Tempered Safety Glass (ESG) |
| Interior | Stainless Steel Construction |
| Shelving | 2 Removable Stainless Steel Trays |
| Stacking Capability | Up to KT115 Units |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 240 |
| Temperature Range | −40 °C to +110 °C (extendable to +120 °C with dual safety cut-off) |
| Temperature Uniformity | ±0.1 K to ±1.2 K (dependent on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K |
| Heating Rate (IEC 60068-3-5) | 5 K/min |
| Cooling Time (110 °C → −40 °C) | 160 min |
| Average Cooling Rate (IEC 60068-3-5) | 3.5 K/min |
| Thermal Compensation at 25 °C | 3000 W |
| Rated Voltage | 400 V or 480 V AC, 3~ |
| Frequency | 50/60 Hz |
| Nominal Power | 5.6 kW |
| Fuse Rating | 16 A |
| Internal Volume | 228 L |
| Net Weight (empty) | 375 kg |
| Max. Load Capacity | 70 kg |
| Shelf Load per Rack | 30 kg |
| Viewing Window | 508 mm × 300 mm (heated, LED-lit) |
| Internal Dimensions (W×H×D) | 735 mm × 700 mm × 443 mm |
| External Dimensions (W×H×D) | 1335 mm × 1929 mm × 925 mm |
| Rear Clearance | 300 mm |
| Side Clearance | 200 mm |
| Sound Pressure Level | 62 dB(A) |
| Safety Systems | Dual independent Class 2 temperature cut-offs (DIN 12880), CO/H₂/O₂/temperature gas monitoring, CO₂ fire suppression, reinforced door lock, reversible stainless-steel pressure relief valve, APT.line™ pre-heating chamber, condensation protection programming, fluorine-free refrigerant R-452A |
| Control Interface | Touchscreen controller with time-segment & real-time programming, APT-COM™ Basic software, Ethernet interface, USB data export (open CSV format), internal datalogger, 230 V socket on right-side panel |
| Standard Equipment | 1 stainless-steel shelf, compressed-air-cooled refrigeration unit |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 720 |
| Temperature Range | –40 °C to +110 °C |
| Temperature Uniformity (±K) | 0.1–0.5 |
| Temperature Stability (±K) | 0.3–2.0 |
| Avg. Heating Rate (IEC 60068-3-5) | 4 K/min |
| Avg. Cooling Rate (IEC 60068-3-5) | 3.4 K/min |
| Internal Volume | 734 L |
| Max. Load Capacity | 160 kg |
| Net Weight | 570 kg (LIT MK 720-400V) / 522 kg (LIT MK 720-480V-C) |
| Power Supply | 400 V, 3~ |
| Refrigerant | R-452A |
| Sound Pressure Level | 65–67 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | M53 / M115 / M240 / M400 / M720 |
| Temperature Range | Ambient +5 °C to 300 °C |
| Internal Volume | 53–720 L |
| External Dimensions (W×H×D) | 1235 mm × 1690 mm × 865 mm |
| Internal Dimensions (W×H×D) | 1000 mm × 1200 mm × 610 mm |
| Heating Method | Forced Convection (Hot Air) |
| Temperature Uniformity at 150 °C | ±1.3–1.9 K |
| Temperature Fluctuation at 150 °C | ±0.3 K |
| Heating Time to 150 °C | 15–21 min |
| Recovery Time after 30-sec Door Opening at 150 °C | ≤3 min |
| Max. Load Capacity | 40–120 kg |
| Max. Shelf Load | 15–45 kg |
| Standard Shelves | 2 (adjustable), Max. Shelves: 5–16 |
| Power Rating (230 V) | 1.2–2.7 kW |
| Power Rating (400 V) | 3.45 kW |
| Interface | Ethernet, USB for Data Logger Export |
| Safety | Dual Independent Temperature Safety Devices (DIN 12880 Class 2 & Class 3.1), Redundant Pt100 Sensor |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | M, MK, MKT |
| Application Scope | Thermal Stress Testing, Stability & Durability Evaluation, Material Aging (per EN 60811-1-2 / IEC 60811-1-2) |
| Compliance | ISO 17025-accredited laboratory use, GLP/GMP-compatible operation, FDA 21 CFR Part 11-ready software options available |
| Cooling Method | Dual-circuit refrigeration with cascade system (for MKT series down to –70 °C) |
| Temperature Range | –70 °C to +180 °C (MKT), –40 °C to +180 °C (MK), –20 °C to +180 °C (M) |
| Uniformity | ±0.3 °C (at 100 °C, load-free) |
| Control System | BINDER CTC Advanced Touchscreen Controller with programmable ramp/soak profiles, real-time data logging, and Ethernet interface |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MDL |
| External Dimensions (L×H×W) | 834×800×685 mm |
| Internal Dimensions (L×H×W) | 600×435×435 mm |
| Temperature Range | +5 °C above ambient to 350 °C |
| Internal Volume | 115 L |
| Temperature Uniformity | ≤ ±0.5 °C |
| Airflow Rate | 400 L/min |
| Heating Power | 9.0 kW |
| Safety Class | Dual independent temperature safety device (DIN 12880, Class 2) |
| Fresh Air Filter | EU6 (F6), particle retention ≥1 µm |
| Rear Exhaust Port | Ø100 mm |
| Shelves | 2 chrome-plated adjustable shelves |
| Controller | MCS microprocessor-based controller with 25 stored programs, 100 segments per program, up to 500 total segments |
| Display | User-friendly LCD with intuitive menu navigation |
| Data Logging | Built-in electronic chart recorder with multiple real-time graphical display options |
| Real-Time Clock | Integrated |
| Ramp Function | Programmable via on-board editor |
| Door Seal | High-temperature silicone gasket |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MK Series |
| Temperature Range | –40 °C to +180 °C |
| Internal Volume | 56–1020 L |
| Temperature Uniformity | ±0.1 K to ±2.0 K (depends on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K (depends on setpoint) |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.5 K/min |
| Refrigerant | R-452A (non-ozone-depleting) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.1–2.0 K (depending on setpoint and chamber size) |
| Temperature Fluctuation | ±0.1–0.5 K |
| Humidity Fluctuation | ≤±2.5 % RH |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.2 K/min |
| Internal Volumes | 115 L / 228 L / 734 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT115 / MKFT240 / MKFT720 |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Internal Volume | 115 L / 228 L / 734 L |
| Refrigerant | R-452A |
| Humidity Control | Capacitive Sensor + Steam Humidification |
| Controller | MCS Touchscreen with Real-Time & Segment Programming |
| Data Logging | Integrated Internal Recorder + USB Export |
| Compliance | DIN 12880, IEC 60068-3-5, IEC 60068-3-6, MIL-STD-810G (climate profiles), GLP/GMP-ready audit trail support via optional software |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKT |
| Temperature Range | -70 °C to +180 °C |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, IEC 60068, MIL-STD-810 |
| Humidity Control | Capacitive Hygrometer + Steam Humidification (MKT models) |
| Refrigerant | R-452A |
| Controller | MCS Touchscreen with Real-Time Clock, Ramp Function, Internal Data Logger |
| Interface | Ethernet, USB, 230 V Socket on Right Side |
| Safety | Optical & Acoustic Fault Diagnostics, Heated Viewing Window with LED Lighting, Silicone-Sealed Access Ports (50 mm for MKT 115/240 |
| Castors | 4, 2 with Brakes |
| Internal Volume | 115 L / 228 L / 734 L (MKT 115 / MKT 240 / MKT 720) |
| Net Weight | 305 kg / 380 kg / 610 kg |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | UF V |
| Temperature Range | -40 °C to -86 °C |
| Insulation | Vacuum Insulation Panels (VIP) + Polyurethane Foam |
| Cooling System | Cascade Compressor |
| Refrigerants | R-404A and R-508B (non-ozone-depleting) |
| Door Configuration | Right- or Left-Hinged with Mechanical Limiter |
| Access Control | RFID-Based (Model-Dependent) |
| Data Logging | USB-Enabled Recorder (Model-Dependent) |
| Cooling Option | Water-Cooled Condenser (Model-Dependent) |
| Door Lock | Motorized Mechanical Lock |
| Interior | Stainless Steel Chamber |
| Interior Shelves | 3 Stainless Steel Pull-Out Trays |
| Compartment Doors | 4 ABS Plastic Doors |
| Alarm System | Battery-Backed Audible/Visual Alarm with Dry Contact Output, Runtime Hour Meter |
| Interfaces | RS-422 Serial Port, 4–20 mA Analog Output, Zero-Voltage Alarm Relay |
| Internal Volume | 477 L (UF V500) / 700 L (UF V700) |
| External Dimensions (W×H×D mm) | 826×1966×938 (UF V500) / 1100×1966×938 (UF V700) |
| Internal Dimensions (W×H×D mm) | 606×1300×605 (UF V500) / 890×1300×605 (UF V700) |
| Net Weight | 247 kg (UF V500) / 288 kg (UF V700) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | VDL |
| Temperature Range | Ambient +15 °C to 200 °C (optional up to 250 °C) |
| Internal Volume | 23 L / 53 L / 115 L |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, ATEX Zone 2/22 (Ex II -/3G c IIB T3–T1 Gc X), RS 422 Interface |
| Construction | Electropolished AISI 316Ti stainless steel chamber, silicone door gasket, spring-mounted safety glass door |
| Features | APT.line™ preheating technology, inert gas inlet with precision dosing valve, compressed air interface for overpressure lockbox, optical temperature alarm, pressure monitoring (<125 mbar release threshold), cross-flow air circulation, programmable ramp/soak profiles, dual aluminum extension shelves, time-of-operation indicator, calibrated venting valve |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | VDL-23 |
| Interior Volume | 23 L |
| Interior Dimensions (W/H/D) | 285 × 285 × 285 mm |
| Temperature Range | +5 °C to 200 °C |
| Temperature Accuracy | ≤ ±0.4 °C |
| Temperature Uniformity @100 °C | ±2.0 °C |
| Temperature Uniformity @200 °C | ±4.0 °C |
| Max. Vacuum Level | 1 × 10⁻² mbar |
| Vacuum Flange Port (DN) | 16 mm |
| Gas Inlet Port (PR) | 3/8″ |
| Compressed Air Connection | Ø8 mm, 50 L/min |
| IP Rating | IP54 (DIN EN 60529) |
| Power Supply | 230 V, ±10 %, 50/60 Hz |
| Rated Power | 800 W |
| Net Weight | 63 kg |
| Standard Shelves | 2 (up to 4 optional) |
| Shelf Load Capacity | 20 kg per shelf |
| Total Load Capacity | 35 kg |
| Shelf Spacing | 53 mm |
| Shelf Usable Area (W × D) | 234 × 280 mm |
| Heating Time to 100 °C | 66 min |
| Heating Time to 200 °C | 90 min |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKF |
| Temperature Range | -40 °C to +180 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Internal Volume | 60 L to 734 L (depending on model) |
| Integrated Water Tank Capacity | 20 L |
| Refrigerant | R-452A |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, IEC 60068, MIL-STD-810, ASTM D4332 |
| Control System | MCS Touchscreen Controller with Time/Real-Time Programming, Built-in Data Logger, USB & Ethernet Interfaces |
| Condensation Protection | Programmable |
| Humidity Generation | Steam-based, Capacitive RH Sensor |