Bladewerx
Filter
Showing all 3 results
| Brand | Bladewerx |
|---|---|
| Origin | USA |
| Model | EpeeCAM |
| Instrument Type | Laboratory-grade Portable Alpha/Beta Aerosol Monitor |
| Flow Rate | 6.0 LPM (adjustable) |
| Flow Accuracy | ±1% FS |
| Timing Accuracy | ±1 s/h |
| Repeatability | ±1% RSD |
| Particle Size Distribution Uncertainty | ±1% (for 0.3–10 µm equivalent aerodynamic diameter) |
| Indication Error | ±1% of full scale |
| Detector | Ion-implanted silicon solid-state detector (450 mm² active area, 500 µm depletion depth) |
| Energy Range | 1.0–8.0 MeV (Rn mode: 1.0–10.0 MeV) |
| MCA Resolution | 256-channel pulse-height analysis with Po-isotope peak fitting (²¹⁴Po, ²¹⁸Po, ²¹²Po, ²³⁹Pu, and one user-defined nuclide) |
| Power | 7.4 V Li-ion battery (4.1 Ah) |
| Dimensions | 12 × 14 × 7.6 cm (4.7 × 5.5 × 3.0 in) |
| Weight | 1.0 kg (2.2 lbs) |
| Operating Temp | −20 to +50 °C |
| Relative Humidity | 5–100% RH (non-condensing) |
| Ingress Protection | IP54-equivalent (splash- and dust-resistant polymer housing, no external ports or protrusions) |
| Data Interface | USB 2.0 (PC connectivity for calibration, configuration, and data export) |
| Software | Included Windows CE-based firmware with RadNet-compatible output (text/.cdt format), real-time spectral display, acute (120 s) & chronic (240 min) integration modes, net count rate alarm logic, and source-response diagnostics |
| Brand | Bladewerx |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SabreAlert |
| Instrument Type | 24-Hour Constant-Temperature & Constant-Flow Air Sampler |
| Instrument Architecture | Multi-Channel Gas Sampler |
| Flow Rate | 6.0 LPM |
| Maximum Vacuum Pressure | 26,000 Pa |
| Flow Stability | ±5% |
| Flowmeter Accuracy | ±2.5% of Full Scale |
| Service Life at Max Flow & Backpressure | 5,000 hours |
| Continuous Operation Time at Max Flow & Backpressure | 2 hours |
| Brand | Bladewerx |
|---|---|
| Origin | USA |
| Model | SabreISC |
| Instrument Type | Laboratory-grade Alpha/Beta Spectrometric Air Sampler |
| Flow Rate | Low-flow (6 L/min standard) |
| Flow Accuracy | < ±3% |
| Timing Accuracy | < ±1 s |
| Repeatability | < ±5% FS |
| Particle Size Distribution Error | Not applicable (energy-resolved spectrometry, not optical sizing) |
| Energy Response Accuracy | < ±10% FS (α), < ±10% FS (β) |
| Detector | Solid-state ion-implanted silicon, 1-in² (450 mm²) or 2-in² (2000 mm²) active area |
| Alpha Energy Range | 1.0–10.0 MeV |
| Beta Energy Range | 100 keV–4 MeV |
| Max Count Rate | 600,000 cpm (α + β combined) |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | 5–100% RH (non-condensing) |
| Power | 12 VDC @ 2.5 A (AC adapter included) |
| Dimensions | 21 × 16 × 30 cm |
| Weight | 2.9 kg (<7 lbs) |
| Battery Backup | Integrated 1-hr Li-ion UPS |
| Display | 7-inch LCD touchscreen (800 × 480) |
| Compliance | Designed for EPA Method 900, ASTM D6330, ISO 7503-1, and compatible with GLP/GMP data integrity requirements (audit trail, user access control, electronic signature support via RadNet software) |