CEM
Filter
Showing 1–30 of 35 results
| Brand | CEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BLADE |
| Quotation | Upon Request |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 24 Samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 310 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity | 0.01 °C |
| Max Pressure | Not Applicable |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Clean-STAR |
| Chamber Class | Industrial-Grade |
| Sample Capacity | 2–6 positions |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 500 °C |
| Operating Pressure | Ambient (Atmospheric) |
| Vessel Options | PTFE (30 mL, 70 mL), Quartz (100 mL) |
| Software | STAR LINK™ PC Interface, 20 Predefined Methods, Real-Time Temp/Time Curve Visualization, Endpoint Detection via Moisture/Volatility Sensing, Integrated Gas Absorption Module |
| Safety | Automated Interlock, Overtemperature & Overpressure Monitoring, HEPA-Filtered Inert Gas Purge (N₂ or Clean Air) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CleavagePro |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 1–10 μmol |
| Reaction Vessel Count | 48 |
| Reaction Vessel Capacity Options | 15 mL / 50 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Instrument Type | Single-Mode Microwave Reactor |
| Temperature Range | –80 °C to 300 °C |
| Pressure Range | 0–35 bar |
| Microwave Power Output | 0–600 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Modes | Electromagnetic + Mechanical Stirring |
| Reaction Vessel Capacity | 300 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | DISCOVER 2.0 |
| Temperature Range | Up to 200 °C |
| Pressure Range | Up to 200 psi (13.8 bar) |
| Microwave Power | 900 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Electromagnetic Stirring |
| Reaction Vessel Capacity | 10 mL |
| Gas Compatibility | H₂, O₂, CO₂, CO, N₂, Ar (non-corrosive only) |
| Temperature Monitoring | Fiber-Optic Probe |
| Pressure Monitoring & Control | Real-time digital pressure sensor with vacuum purge and vent capability |
| Gas Dosing | Programmable mass-flow-controlled gas introduction |
| System Integration | Fully compatible with CEM DISCOVER modular platform |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Discover 2.0 (Single-Mode) |
| Temperature Range | 0–300 °C |
| Pressure Range | 0–35 bar (500 psi) |
| Microwave Power Output | 0–900 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Modes | Electromagnetic + Optional Mechanical Stirring |
| Reaction Volume Capacity | 300 mL |
| Cavity Type | Ring-Focused Single-Mode |
| Cooling Technology | PowerMAX Synchronized Active Cooling |
| Control Interface | 10.1" Touchscreen with TimeWave Embedded OS |
| Camera Integration | 5 MP Real-Time Imaging Module |
| Compliance | ISO 9001, CE, ETL, FDA 21 CFR Part 11 Ready (via Synergy PC Software) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Discover Hydrolysis |
| Quotation | Upon Request |
| Reaction Method | Single-Mode Microwave |
| Reaction Time | 10 minutes |
| Sample Volume per Vial | 300 µL (up to 10 vials) |
| Temperature Control Range | 0–300 °C |
| Hydrolysis Scale | 1 pmol – 1 fmol |
| Vial Format | HPLC-compatible glass autosampler vials (100–300 µL) |
| Temperature Sensor | In-situ fiber-optic probe (RT–300 °C) |
| Vacuum Level | 25 mmHg |
| Stirring Mechanism | Magnetic stirring |
| Atmosphere Control | Alternating vacuum/N₂ purging via integrated valve panel |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DISCOVER SP-D |
| Price | Upon Request |
| Cavity Class | Industrial-Grade |
| Sample Capacity | Automated 48/72/96-Position |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 27 bar |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | DISCOVER SPS |
| Reaction Mode | Single-Mode Microwave |
| Max. Reaction Volume | 300 mL |
| Sample Throughput | 14 samples per run |
| Temperature Range | 0–300 °C |
| Typical Enzymolysis Temperature | 55 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Sensing | In-situ Fiber-Optic Probe |
| Mixing | Magnetic Stirring |
| Cooling | 5 PSI Forced Air |
| Sample Vial Format | 1.5 mL Microcentrifuge Tubes |
| Minimum Sample Volume | 30 µL |
| Hydrolysis Time (Typical) | 10–15 min |
| Enzyme-to-Protein Ratio Range | 1:100 to 1:10 |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EDGE |
| Instrument Type | Liquid–Solid Extraction |
| Temperature Range | 100–200 °C |
| Pressure Range | 13.8 MPa |
| Extraction Cell Volumes | 11 / 22 / 34 / 66 mL |
| Extraction Time | 5 min per sample |
| Instrument Dimensions | 360 mm (W) |
| Sample Capacity | 24 positions (dual rack, 12 per run) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | ETC |
| Cleaning Agents | HNO₃, HCl, HF, H₂SO₄ |
| External Dimensions | Ø330 mm × 400 mm (H) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Explorer (Single-Mode) |
| Temperature Range | 0–350 °C |
| Pressure Range | 0–500 psi |
| Microwave Power | 900 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Electromagnetic |
| Reaction Vessel Volume | 300 mL |
| Cavity Type | Circular Single-Mode |
| Real-Time Pressure Monitoring | 0–35 bar |
| Low-Temperature Capability | Down to –80 °C |
| Automation | XYZ Robotic Arm with 12/24/48-Position Auto-Sampler |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Liberty Lite 2.0 |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 0.005–5 mmol |
| Reactor Count | 4 |
| Reactor Volume Range | 10–125 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Liberty Prime 2.0 |
| Quotation | Upon Request |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.0005–5 mmol |
| Number of Reactors | 3 |
| Reactor Volume Range | 10–125 mL |
| Syringe Pump Accuracy | ±0.01 mL |
| Crude Peptide Purity | >70% |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Liberty PRO |
| Pricing | Upon Request |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 15–1000 mmol |
| Reactor Count | 3 |
| Reactor Volume Options | 3 L, 8 L, 15 L (max. 15 L capacity) |
| Crude Peptide Yield per Batch | Up to 1 kg |
| Synthesis Purity | ≥99% |
| Temperature Control | NIST-Traceable Internal Sensor |
| Stirring Modes | Mechanical Agitation + N₂ Sparging |
| Regulatory Compliance | cGMP-Compliant Materials & Architecture |
| Key Patented Technologies | CarboMAX™ Coupling, HE-SPPS (High-Efficiency Solid-Phase Peptide Synthesis), No-Wash Deprotection/Coupling |
| Core Patents | US7393920 |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Role-Based Access Control |
| Validation Documentation | FAT, IQ/OQ, FDS/SDS, Leachables & Extractables Reports, ATEX Hazard Analysis |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | LibertyBlue 2.0 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| User Authentication | Password + Facial Recognition |
| Audit Trail | Yes |
| Synthesis Scale | 0.005–5 mmol |
| Reactor Count | 4 |
| Reactor Volume Range | 10–125 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS 6 |
| Batch Capacity | 0–40 samples |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 260 °C / 330 °C |
| Temp Accuracy | ±0.1 °C |
| Temp Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 500 psi / 2200 psi |
| Cavity Volume | 66 L |
| Microwave Output Power | 1800 W (IEC 705:1988) |
| Operating Voltage | 220 VAC, 50 Hz, 15 A |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS 7 |
| Chamber Class | Industrial-Grade |
| Batch Capacity | 40 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 350 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 3000 psi |
| Brand | CEM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MARS Xpress 2.0 |
| Price | Upon Request |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 1–40 |
| Microwave Source | Dual Magnetron |
| Maximum Temperature | 330 °C |
| Maximum Pressure | 1500 psi |
| Temperature Measurement Accuracy | Contact manufacturer |
| Temperature Control Stability | Contact manufacturer |
| Temperature Uniformity | Contact manufacturer |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS-X |
| Microwave Power Output | 0–1600 W (IEC standard) |
| Microwave Frequency | 2450 MHz |
| Temperature Control Range | 0–330 °C |
| Temperature Accuracy | ±0.1 °C |
| Cavity Material | 316 stainless steel with multi-layer fluoropolymer corrosion-resistant coating |
| Maximum Batch Capacity | 40 independently sealed vessels |
| Safety Certification | EPA 25200.1.5 compliant |
| Regulatory Compliance | FDA 21 CFR Part 11 data integrity, ASTM/AOAC/EPA method-validated platform |
| Cooling | Turbulent forced-air + optional water-cooling, in-situ rapid cooldown |
| Pressure Monitoring | Full-vessel real-time pressure control up to 1500 psig |
| Vessel Compatibility | TFM, PFA, quartz, and Pyrex vessels (100 µL – 100 mL) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORACLE |
| Quotation | Upon Request |
| Extraction Chamber Volume | 10 mL |
| Receiving Bottle Volume | 110 mL |
| Temperature Range | Ambient |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 1 |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Instrument Type | Box-Type Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 1950 W (Dual Magnetron) |
| Heating Method | Microwave |
| Internal Chamber Volume | 1.8 L / 5 L |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | PHOENIX Black |
| Instrument Type | Box-Type Microwave Muffle Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power Output | 1950 W |
| Ramp Time to Max Temperature | 10 min |
| Heating Method | Microwave |
| Internal Chamber Dimensions | 24.6 × 16.7 × 10.1 cm |
| Chamber Volume | 1.8 L (standard) / 5 L (optional) |
| Airflow Capacity | 100 CFM (standard), up to 130 CFM (with optional Airwave Amplifier) |
| Crucible Cooling Time | <30 s (1200 °C → ambient) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | PHOENIX BLACK |
| Instrument Type | Box-Type Microwave Muffle Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power Output | 1950 W |
| Ramp-to-Max-Temp Time | 10 min |
| Heating Method | Microwave |
| Internal Cavity Dimensions | 24.6 × 16.7 × 10.1 cm |
| Cavity Volume | 1.8 L (standard) / 5 L (optional) |
| Cooling Time (1200 °C → RT) | <30 s |
| Airflow Capacity | 100 CFM (standard), up to 130 CFM (with optional Airwave booster) |
| Compliance | ASTM D5630-94, ASTM D1509-94b, USP <281>, USP <733>, NIST-traceable temperature calibration |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Instrument Type | Box-Type Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 1400 W |
| Ramp Time to Max Temp | 10 min |
| Heating Method | Microwave |
| Internal Chamber Dimensions | 24.6 × 16.7 × 10.1 cm |
| Chamber Volume | 1.8 L (standard) / 5 L (optional) |
| Cooling Time (1200 °C → RT) | <30 s |
| Exhaust Flow Rate | 100 CFM (standard), up to 130 CFM (with adjustable flow amplifier) |
| Safety | NIST-traceable internal temperature calibration, infrared microwave leakage monitoring, BITS real-time component diagnostics, RS232 interface for balance/printer integration |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy 2.0 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 4–250 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 300 bar |
| Wavelength Range | 190–500 nm |
| Wavelength Repeatability | ±3 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | RAZOR |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Operator Authentication | Password + Facial Recognition |
| Audit Trail | Yes |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | SAM-255 |
| Temperature Range | 0–1200 °C |
| Temperature Uniformity | ±1 °C |
| External Dimensions | 46.15 × 65.40 × 49.78 cm |
| Internal Chamber Dimensions | 24.6 × 16.7 × 10.1 cm |
| Power Supply | 120 VAC, 60 Hz / 230 VAC, 50 Hz |
| Total Power Rating | 650 W ± 50 W |
| Magnetron Frequency | 2455 MHz |
| Exhaust Flow Rate | 3.7 m³/min (130 CFM) |
| Interface | RS-232 (9-pin), Parallel Port (25-pin) |
| Balance Compatibility | RS-232–enabled analytical balance (up to 100 g, 0.1 mg resolution) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | SMART Q |
| Heating Method | Infrared |
| Measurement Range | 0.01–15% moisture content |
| Resolution | 0.001% |
| Balance Precision | 0.0001 g (4-digit analytical balance with 3-digit moisture display) |
| Sample Types | Solids, powders, slurries, non-polar solvents, low-moisture polymers, coatings, pharmaceuticals |
| Compliance | Designed for GLP/GMP environments |