| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | JB-2020 |
| Instrument Type | Specific Surface Area Analyzer |
| Principle | Dynamic (Flow-through) Nitrogen Adsorption |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Pressure Control Range | 1–5 kPa (gauge) |
| Theoretical Basis | Dynamic nitrogen adsorption coupled with cryogenic adsorption thermodynamics and gas chromatographic response calibration |
| Operating Ambient Temperature | 10–36 °C |
| Repeatability Error | ≤ ±3% |
| Accuracy Error | ≤ ±3% |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type, U-shaped) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Ultra-high-purity nitrogen (≥99.999%) |
| Software Compatibility | Windows 7 / Windows 10 (32/64-bit) |
| Dimensions (W×D×H) | 700 × 360 × 710 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Environmental Requirements | 5–35 °C ambient temperature |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-2020 |
| Instrument Category | Specific Surface Area Analyzer |
| Operating Principle | Dynamic (Flow) Nitrogen Adsorption at Cryogenic Temperature |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited upper bound |
| Pressure Control Range | 1–5 kPa (gauge) |
| Theoretical Basis | Dynamic nitrogen adsorption coupled with thermal desorption detection and calibrated gas chromatographic response |
| Calibration Standards | GBW(E)130275 certified reference material (CRM), compliant with GB/T 19587–2017 |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type), U-shaped configuration |
| Repeatability | ≤ ±3% RSD |
| Accuracy | ≤ ±3% (vs. certified CRM) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Liquid-nitrogen-cooled high-purity nitrogen (≥99.999%) |
| Test Duration per Sample | ~3 minutes |
| Software Platform | Windows 10 / Windows 7 compatible |
| Dimensions | 700 mm × 360 mm × 710 mm (W × D × H) |
| Net Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Ambient Requirements | 5–35 °C, RH <85% non-condensing |
| Detection System | Low-temperature, high-sensitivity thermal conductivity detector (TCD) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JB-2020 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Low-Temperature Nitrogen Adsorption) |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Pressure Range | 1–5 kPa (gauge) |
| Test Theory | Dynamic nitrogen adsorption at 77 K using helium carrier gas and pulsed nitrogen dosing, based on chromatographic response integration |
| Calibration Standard | GBW(E)130275 certified reference material (CRM) per GB/T 19587–2017 |
| Repeatability Error | ≤ ±3% |
| Accuracy Error | ≤ ±3% |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type U-tube) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Ultra-high-purity nitrogen (≥99.999%) |
| Software Compatibility | Windows 7 / Windows 10 (32/64-bit) |
| Dimensions | 700 mm × 360 mm × 710 mm (W×D×H) |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% non-condensing |
| Analysis Time per Sample | ~3 minutes (single-point or multi-point BET) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic Instrument |
| Model | JB-5 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Chromatography-Based) |
| Measurement Range | 0.0005 m²/g to unlimited |
| Theoretical Basis | BET Theory via Low-Temperature Nitrogen Adsorption (Dynamic Chromatographic Mode) |
| Repeatability | >99% |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-5 Series |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Low-Temperature Nitrogen Adsorption with Helium Carrier Gas) |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Calibration Standard | ISO 9277 & GB/T 19587–2004 |
| Accuracy | ≤ ±1% (verified using certified reference materials) |
| Sample Tube Material | High-Temperature-Resistant GG Glass U-Tube |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Adsorbate Gas | Ultra-High-Purity Nitrogen (≥99.999%) |
| Test Modes | Single-Point, Multi-Point BET, Comparative Analysis |
| Cycle Time per Sample | 5–7 minutes |
| Software Platform | Windows XP/7/10 Compatible |
| Dimensions (L×W×H) | 700 × 300 × 600 mm |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JB-50 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow (Carrier Gas Chromatographic) Method |
| Measurement Range | 0.0005 m²/g to unlimited |
| Theoretical Basis | Gas Adsorption BET Theory with Gaseous Chromatography Detection |
| Repeatability | >99% |
| Standards Compliance | ISO 9277, GB/T 19587–2017 |
| Sample Throughput | 4 independent stations |
| Analysis Time per Sample | 5–7 minutes |
| Calibration | Certified Reference Materials (e.g., NIST-traceable SiO₂ or α-Al₂O₃) |
| Detector | Low-Temperature High-Sensitivity Thermal Conductivity Detector (TCD) |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Adsorbate | Ultra-High-Purity Nitrogen (≥99.999%) |
| Sample Tube | U-shaped GG-glass (borosilicate), high-temp resistant |
| Cryogenic System | 500 mL Dewar flask with vacuum-insulated double-wall glass |
| Flow Control | Precision Mass Flow Regulators & Pressure-Stabilized Valves |
| Software | Windows XP/7/10 compatible |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area Analyzer |
| Principle | Dynamic Flow Method (Low-Temperature Nitrogen Adsorption) |
| Analysis Stations | 1 |
| Measurement Range | 0.1–3500 m²/g |
| Pressure Control Range | 1–5 (arbitrary unit, calibrated via standard gas pulses) |
| Theoretical Basis | BET Theory |
| Repeatability | ≤ ±3% |
| Sample Tube Material | High-Temperature-Resistant GG Glass (U-Shaped) |
| Calibration Standard | GBW(E)130275 Certified Reference Material |
| Test Gases | Ultra-High-Purity Helium (carrier) and Nitrogen (adsorbate) |
| Software Compatibility | Windows 7 / Windows 10 |
| Dimensions | 700 × 360 × 710 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% |
| Test Duration per Sample | ~3 minutes |
| Data Output | Exportable reports with storage, query, comparison, editing, and deletion functions |
| Measurement Modes | Single-Point, Multi-Point BET, Comparative Analysis |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China-made) |
| Model | JL Series |
| Pricing | Available Upon Request |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | ≥99% |
| Measurement Time | ≤2 minutes |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–200 µm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | ~60 seconds per sample |
| Dispersion Method | Wet dispersion with 60 W ultrasonic probe |
| Sample Cell | 60 mm × 60 mm fused quartz |
| Circulation System | Integrated stainless-steel (304) 500 mL dispersion tank with peristaltic pump and mechanical stirrer |
| Optical Design | Inverted Fourier optical system |
| Detector | 52-channel multi-element photodiode array |
| Light Source | 650 nm, 30 mW semiconductor laser (lifetime >70,000 h) |
| Software | Windows-compatible analysis suite with volume/number distribution, D10/D50/D90, specific surface area, and GLP-compliant data export (PDF, CSV) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | ≤1% (D50 deviation vs. NIST-traceable standard reference materials) |
| Measurement Time | ≤2 minutes per sample |
| Dispersion Method | Wet dispersion with integrated 60 W ultrasonic probe and mechanical stirring |
| Optical System | Inverted Fourier configuration with dual-wavelength laser sources (650 nm / 30 mW primary |
| Detector Array | 98-channel high-resolution photodiode array |
| Sample Cell | 60 mm × 60 mm optical-grade fused silica window |
| Dispersant Volume | 500 mL stainless steel (304) dispersion chamber |
| Compliance | GB/T 19077–2016, ISO 13320:2020, ASTM E799–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JL-1177 |
| Price Range | USD 21,000–22,500 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01 µm to 3000 µm |
| Repeatability | ≤1% (D50 deviation against NIST-traceable standard reference materials) |
| Measurement Time | ≤120 s per sample |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-1177 |
| Price Range | USD 11,200–14,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 3000 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 seconds |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-1178 |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Repeatability | <1% (RSD for D50) |
| Measurement Time | ≤10 s per sample |
| Test Principle | Mie Scattering & Fraunhofer Diffraction |
| Detector Array | 128-channel multi-element photodetector |
| Light Source | Dual-wavelength semiconductor laser (650 nm / 30 mW primary |
| Optical Design | Inverted Fourier optical system with auto-aligned f-theta lens |
| Air Pressure Range | 0.1–0.8 MPa (adjustable) |
| Sample Mass | 2–10 g per test |
| Operating Environment | 5–35 °C, AC 220 V ±10%, 50 Hz |
| Compliance | GB/T 19077–2016, ISO 13320:2020 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Dispersion Method | Dry Air Jet Dispersion |
| Repeatability | ≤3% (D50 deviation against national standard reference materials) |
| Measurement Time | ≤60 seconds per sample |
| Optical Principle | Mie Scattering & Fraunhofer Diffraction |
| Detector Array | 128-channel multi-angle photodetector |
| Light Source | Dual-wavelength semiconductor laser (650 nm / 30 mW primary |
| Sample Consumption | 2–10 g per test |
| Dispersion Pressure | Adjustable 0.1–0.8 MPa |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C |
| Compliance | GB/T 19077–2016, ISO 13320 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 1 nm – 3000 µm |
| Repeatability | ≤1% RSD for D50 (micron- and nano-grade reference standards) |
| Measurement Time | 2–3 minutes per sample |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-1197 / JL-1198 |
| Price Range | USD 21,000–28,000 (FOB) |
| Particle Size Measurement Range | 1 nm – 3000 µm |
| Measurement Repeatability | ≤1% (D50 deviation against NIST-traceable standard materials) |
| Operating Temperature Range | 5–40 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Optical Signal Sampling Frequency | 100 Hz |
| Sample Introduction Method | Fully Integrated Wet Dispersion Circulation System |
| Sample Volume Requirement | 0.1–5 mL per test (dependent on density, refractive index, and particle morphology) |
| Test Duration | 2–5 minutes per sample (automated sequence) |
| Detection Principle | Dual-mode — Photon Correlation Spectroscopy (PCS) for sub-100 nm particles |
| Detector Configuration | 128-element multi-channel photomultiplier tube array with high-gain, low-noise amplification |
| Optical Architecture | Inverted Fourier optical system with dual-laser path (635 nm semiconductor laser, >70,000 h lifetime) |
| Data Output Formats | CSV, PDF, TXT, XML |
| Software Language Options | English or Simplified Chinese UI |
| Compliance | Meets ISO 13321 (PCS), ISO 13320 (Laser Diffraction), and GB/T 19077–2016 (Chinese national standard for particle size analysis) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, slurries, and filtration media |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Volume Range | 0.01–100 cm³ |
| Temperature Range | 5–35 °C |
| Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Pressure Control | Absolute pressure mode (0–130 kPa), vacuum-assisted degassing |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Software Interface | Windows 7 or later |
| Communication | RS-232 or USB |
| Power | AC 220 V ±22 V, 50 Hz |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Price Range | USD 5,600 – 7,000 (est.) |
| Application Field | General-purpose true density analysis |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — correction per technical specs) |
| Sample Type | Solid materials (powders, granules, monoliths, foams, slurries, filters) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium displacement, based on ideal gas law) |
| Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Control | Absolute pressure mode (vacuum-based), 0–130 kPa absolute |
| Test Gas | 99.99% purity N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±10%, 50 Hz, <200 W (vacuum mode) |
| Dimensions | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014 (gas pycnometry), ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Category | Portable Solid Density Analyzer |
| Measurement Principle | Gas Displacement Pycnometry (ISO 12154:2014, GB/T 24586–2009) |
| Sample Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Mode | Absolute Vacuum Mode (0–130 kPa absolute) |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Vacuum Mode Power Consumption | <200 W |
| Dimensions (L×W×H) | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation) |
| Sample Type | Solids (powders, granules, bulk solids, foams, filter media, slurries) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ASTM D5550 / ISO 12154 compliant) |
| Density Range | 0.01–100 g/cm³ |
| Temperature Control Range | 15–39 °C |
| Repeatability | ±0.02% RSD |
| Resolution | 0.00001 g/cm³ |
| Sample Volume Capacity | 0.01–100 cm³ (with interchangeable sample chambers: 10 mL, 30 mL, 60 mL, and fixed 100 mL reference chamber) |
| Test Duration | ~3 min per analysis (fully automated) |
| Pressure Mode | Absolute pressure vacuum system (0–130 kPa absolute), integrated vacuum pump |
| Calibration Standard | Certified stainless steel sphere (included) |
| Software Interface | Windows 7 or later, RS232/USB |
| Compliance | GB/T 24586–2009, ASTM D5550–22, ISO 12154:2014, USP <699> (for density determination in pharmaceutical excipients) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, filters, slurries |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Volume Range | 0.01–100 cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Temperature Range | 5–35 °C |
| Operating Pressure | Absolute pressure mode, 0–130 kPa |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Calibration Standard | Certified stainless-steel sphere |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Power Consumption | <200 W (vacuum mode), <50 W (positive-pressure mode) |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-3000 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | 10 s per analysis |
| Measurement Principle | Full-range Mie Scattering Theory |
| Optical System | Parallel-beam Fourier Configuration with f-Theta Lens |
| Light Source | Imported Semiconductor Laser, 650 nm, 30 mW, >70,000 h Lifetime |
| Detector | 128-channel Multielement Photodiode Array |
| Repeatability Error | ≤3% (D50 of NIST-traceable Standard Reference Material) |
| Accuracy Error | ≤3% (D50 of SRM) |
| Main Unit to Auxiliary Unit Spacing | 400 mm |
| Dimensions (L×H×W) | 1130 × 340 × 200 mm |
| Weight | ~50 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% |
| Data Output | Cumulative Distribution, Frequency Distribution, D10/D50/D90/D97, Mean Diameter, Specific Surface Area |
| Trigger Options | Software-initiated, TTL-level, or External Switch Trigger (up to 50 full analyses/sec) |
| Interface | RS-232 and USB 2.0 (transmission distance up to 100 m) |
| Software Compatibility | Windows XP / 7 / 10 |
| Language Support | English and Chinese UI |
| Data Export | PDF, CSV, XML, and direct print |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | JL-3000 Integrated |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | 10 s per analysis |
| Measurement Principle | Full-range Mie Scattering Theory |
| Optical System | Fourier Transform with Parallel Beam & Large-Diameter Lens |
| Detector | 128-channel Multielement Photodiode Array |
| Laser Source | Imported Semiconductor Laser, 650 nm, 30 mW, >70,000 h Lifetime |
| Repeatability Error | ≤3% (D50 of NIST-traceable Standard Reference Material) |
| Accuracy Error | ≤3% (D50 of NIST-traceable Standard Reference Material) |
| Main Unit–Auxiliary Unit Spacing | 400 mm |
| Dimensions (L×H×W) | 1130 × 340 × 200 mm |
| Weight | ~50 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% |
| Data Output | Cumulative Distribution, Frequency Distribution, D10/D50/D90/D97, Mean Diameter, Specific Surface Area |
| Trigger Options | Software Command, TTL Pulse, Mechanical Switch (up to 50 Hz acquisition rate) |
| Interface | RS232 + USB 2.0 (transmission distance up to 100 m) |
| Software Compatibility | Windows XP / 7 / 10 |
| Language Support | English & Chinese UI |
| Reporting | Direct Print, PDF Export, CSV Export |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | JL-3000 |
| Price Range | USD 21,000 – 22,500 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | ≤10 s per analysis |
| Measurement Principle | Full-Range Mie Scattering Theory |
| Detector Channels | 128 |
| Repeatability Error | ≤1% (D50 of NIST-traceable standard reference material) |
| Accuracy Error | ≤1% (D50 of NIST-traceable standard reference material) |
| Optical System | Fourier Transform Lens, 80 mm Aperture |
| Light Source | Imported Semiconductor Laser, 650 nm, 30 mW, >70,000 h Lifetime |
| Host-Footprint Dimensions | 900 × 370 × 270 mm |
| Auxiliary Unit Dimensions | 330 × 250 × 370 mm |
| Host–Auxiliary Separation Distance | 1–10 m (adjustable) |
| Data Interface | RS-232 & USB 2.0 (transmission up to 100 m) |
| Operating System Compatibility | Windows XP / 7 / 10 |
| Environmental Requirements | 5–35 °C, RH <85% non-condensing |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-3000A |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Repeatability | <1% (RSD for D50) |
| Measurement Time | 10 s per analysis |
| Optical Principle | Full-range Mie Scattering Theory |
| Sampling Mode | Open-flow spray sampling |
| Optical System | Parallel-beam Fourier configuration with large-diameter lens |
| Light Source | Imported semiconductor laser, 650 nm, 30 mW, >70,000 h lifetime |
| Detector | 128-channel multi-element photodiode array with per-channel background compensation |
| Data Interface | RS232 and USB 2.0 (up to 100 m transmission distance) |
| Trigger Options | Software control, TTL pulse, mechanical switch (up to 50 full analyses/sec) |
| Software Compatibility | Windows XP / 7 / 10 |
| Output Parameters | Cumulative distribution, frequency distribution, D10/D50/D90/D97, mean diameter, specific surface area, span, relative width |
| Environmental Requirements | 5–35 °C, RH <85%, AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Dimensions (L×H×W) | 1130 × 340 × 200 mm |
| Weight | ~50 kg |
| Host-to-Spray-Stage Distance | Fixed 400 mm |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-6000 |
| Price Range | USD 21,000–22,500 (FOB) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Repeatability | <1% (wet), <3% (dry) |
| Measurement Time | <10 s (per measurement), <2 min (wet cycle incl. dispersion/cleaning), <60 s (dry cycle incl. auto-feed/clean) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | JL-6000 |
| Price Range | USD 21,000–22,500 (FOB China) |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Repeatability | <1% (wet), <3% (dry) |
| Measurement Time | <2 min (wet), <5 s per run (dry) |
| [Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Hall Flow Tester, Apparent Density Tester, Angle of Repose Tester |
| Measurable Parameters | Flow Time (s/50g), Angle of Repose (°), Apparent Density (g/cm³) |
| Standardized Compliance | GB/T 1482–2010, GB/T 1479.1–2017, GB/T 16913–2008 |
| Sample Mass Range | 50–100 g |
| Stainless Steel Cup Volume | 25 mL |
| Funnel Orifice Diameter | 5 mm (standard), optional 2.5 mm |
| Funnel Cone Angle | 60° |
| Repose Plate Diameter | 80 mm |
| Ruler Width | 25 mm |
| Dimensions | 300 × 260 × 260 mm |
| Net Weight | ~5 kg] |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Angle of Repose Tester, Apparent Density Tester, Powder Flowability Tester |
| Measurable Parameters | Angle of Repose, Flow Time (Haller Flow Rate), Apparent Density |
| Maximum Sample Cup Capacity | 25 mL (standard stainless steel cup) |
| Minimum Sample Mass | 50 g |
| Funnel Orifice Diameter | 5 mm (standard), optional 2.5 mm or custom |
| Funnel Cone Angle | 60° |
| Repose Plate Diameter | 80 mm |
| Stainless Steel Ruler Width | 25 mm |
| Dimensions | 300 × 260 × 260 mm |
| Net Weight | ~5 kg |
| Compliance | GB/T 1482–2010, GB/T 1479.1–2017, GB/T 16913–2008 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Hall Flowmeter, Bulk Density Tester, Angle of Repose Analyzer |
| Measurable Parameters | Flow Time (s/50g), Angle of Repose (°), Bulk Density (g/cm³) |
| Standard Funnel Orifice | 5 mm (optional 2.5 mm or custom) |
| Stainless Steel Cup Capacity | 25 mL |
| Minimum Sample Mass | 50 g |
| Maximum Sample Mass | 100 g |
| Compliance | GB/T 1482–2010, GB/T 1479.1–2017, GB/T 16913–2008, ISO 4490:2018 (referenced), ASTM B213–22 (method-equivalent) |