Cole-Parmer
Filter
Showing all 7 results
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 36050-05 |
| Operating Temperature | 760°C (1400°F) |
| Length | 0.6 m |
| Width | 1.3 cm |
| Power Rating | 156 W |
| Voltage | 120 VAC |
| Construction | Dual resistive elements knitted in series, insulated with high-temp Samox® fiberglass braid |
| Safety Note | Non-overlapping installation required |
| Termination | Reusable tie-down ends, 0.6 m integrated power cord |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 44175-00 |
| Temperature Range | −10 to 100 °C |
| Temperature Accuracy | ±1 °C |
| Timer Function | Up to 30 days with audible alarm |
| Data Storage | Built-in memory |
| Interface | RS232 (IBM PC compatible) |
| Power Supply | 100–232 V AC |
| Standard Configuration | Main unit + 12 V DC power supply (modules sold separately) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 74900-25 |
| Pump Type | Microfluidic Syringe Pump |
| Flow Rate Range | 0.001 µL/h to 147 mL/min |
| Accuracy | ±0.5% |
| Repeatability | ±0.2% |
| Syringe Capacity | 10 µL to 140 mL |
| Plunger Speed | 9.5 × 10⁻⁶ mm/min (min) |
| Maximum Force | 40 lbf |
| Communication Interface | RS-232 |
| Display | Backlit LCD with alphanumeric interface |
| Power Supply | Included 6-ft grounded AC cord |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 74900-05 (Single-Channel), 74900-15/74900-25/74900-65/74901-05 (Dual-Channel), 74900-35/74900-45/74900-85/74901-15 (10-Channel) |
| Accuracy | ±0.5% |
| Repeatability | ±0.1% |
| Flow Rate Range (Single) | 0.2 µL/h–500 mL/h |
| Flow Rate Range (Dual/10-Channel) | 1 nL/h–147 mL/min |
| Syringe Capacity | 10 µL–140 mL |
| Linear Force | 9.1 kg (Single), 18.1 kg (Dual/10-Channel) |
| Power Supply | 230 V, 50/60 Hz |
| Certifications | CE |
| Interface | RS232, TTL I/O (Programmable Models) |
| Dimensions (L×W×H, cm) | 23×10×15 (Single), 28×12.7×23.5 (Dual), 28×15.2×30.5 (10-Channel) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 36402-09 |
| Temperature Range | Ambient to 130 °C |
| Temperature Uniformity | ±0.3 °C |
| Input Voltage | 230 V AC |
| Power Rating | 150–400 W (model-dependent) |
| Module Capacity | Single-module configuration |
| Heating Module Depth | 2.8 cm (03137-00 only) |
| Brand | Cole-Parmer |
|---|---|
| Model | 36630-00 |
| Origin | USA |
| Instrument Type | Benchtop |
| Temperature Range | −30 °C to +150 °C |
| Stirring Speed | 350–1200 rpm |
| Independent Reaction Vessels | 10 |
| Vessel Volume Capacity | 1–25 mL |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.5 °C |
| Stirring Speed Resolution | 1 rpm |
| Stirring Speed Accuracy | ±10 rpm |
| Max Heating/Cooling Rate | 5 °C/min |
| Inter-vessel Temp Differential | Up to 180 °C |
| Optional Accessories | Reflux condensers, inert gas/vacuum manifolds, multi-channel NIR probes (Clarity System), Multi-Temp10 thermal control module, Integrity software suite |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 34788-00 |
| Viewing Window | 6.35 mm (1/4") thick acrylic, angled design |
| Humidity Range Monitoring | 20–95% RH |
| Gas Inlet/Outlet Valves | 2 × 1/4" OD ball valves |
| Standard Gloves | 1 pair of medium-size latex gloves (15 cm cuff diameter, 61 cm length) |
| Transfer Chamber External Dimensions | 22 × 21 × 21 cm (L × W × H) |
| Overall External Dimensions | 69 × 51 × 51 cm (L × W × H) |
| Weight | 65 kg |
| Chamber Internal Dimensions | 68.6 × 50.8 × 50.8 cm (27 × 20 × 20 in) |
| Transfer Chamber Internal Dimensions | 68.6 × 50.8 × 50.8 cm (27 × 20 × 20 in) |
| Interface Port Size | 1/4" OD |