COMECAUSE
Filter
Showing 1–30 of 253 results
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN_G30 |
| Key Specifications | 180° fisheye lens |
| Image Resolution | 2592 × 1944 |
| PAR Spectral Range | 400–700 nm |
| PAR Measurement Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Angular Coverage | Zenith angle 0°–90° (hemispherical), subdivided into 10 zenith zones & 10 azimuth zones |
| Operating Temperature | −10°C to 55°C |
| Relative Humidity | ≤85% RH |
| Weight | 500 g |
| Interface | USB |
| Software | COMECAUSE Canopy Analysis System v3.x |
| GPS Integration | Real-time geotagging (latitude/longitude) |
| Data Output | Cloud-sync capable (secure agricultural cloud platform) |
| Language Support | Switchable bilingual UI (English/Chinese) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IN_GD20 |
| Price | USD 5,300 (FOB Qingdao) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | IN_GX01 |
| Imaging Sensor | 20 MP Auto-Focus Color Camera |
| Max Analysis Area | 297 mm × 210 mm |
| Minimum Resolvable Root Diameter | ≥ 0.5 mm |
| Output Formats | CSV, Excel (.xlsx), PNG/JPEG with Annotation Layers |
| Software Interface | Windows 10 Professional/Enterprise (64-bit) |
| Cloud Sync | Integrated Secure Web Portal |
| Language Support | English & Chinese (Switchable) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN_GX02 |
| Optical Resolution | 4800 × 9600 dpi (A4+ extended) |
| Scan Area (Reflective) | 355.6 mm × 215.9 mm |
| Scan Area (Transmissive) | 320.0 mm × 203.2 mm |
| Minimum Pixel Size | 0.005 mm × 0.0026 mm |
| Light Source | Dual Cold Cathode Fluorescent Lamp (CCFL) Illumination System |
| Image Formats Supported | TIFF, JPEG |
| Software Interface | USB 2.0, Windows 10 Professional/Ultimate (64-bit), Dual-Language (English/Chinese) |
| Cloud Data Sync Capability | Yes |
| Compliance | ASTM D7250 (for image-based dimensional analysis), ISO/IEC 17025-aligned data traceability architecture |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Portable |
| Detection Principle | Chemical Colorimetry |
| Number of Detection Channels | 4 |
| Test Parameters | Nitrogen (N), Phosphorus (P), Potassium (K), Organic Matter, pH, EC, Moisture, and 28+ additional macro/micronutrients in soil, fertilizer, water, plant tissue, and crop samples |
| Measurement Range | 0.001–9999 (unitless absorbance-derived concentration scale) |
| Repeatability | ≤0.03% (as CV, measured with potassium dichromate solution) |
| Brand | COMECAUSE |
|---|---|
| Model | IN_LeafClear |
| Camera Resolution | 1608 × 1104 |
| Pixel Size | 9 µm × 9 µm |
| Frame Rate | 100 fps |
| Bit Depth | 12-bit |
| Interface | USB 3.0 |
| Lens Focal Length | 12 mm |
| Max Aperture | F/2.8 (adjustable) |
| HFOV | 62.11° |
| VFOV | 44.83° |
| Max Imaging Area | 50 cm × 35 cm |
| Excitation Wavelengths | 450 nm (blue), 630 nm (red), 730 nm (far-red) |
| LED Intensity Range | 1–100% (up to 1440 µmol·m⁻²·s⁻¹) |
| OJIP Acquisition Time | 0.1–1.0 s (min Δt = 10 ms) |
| PAM Sampling Interval | 0.1–10.0 s (min Δt = 100 ms) |
| Fluorescence Dynamic Range | 0–4095 (12-bit), SNR > 100:1, Repeatability CV < 3%, Linearity R² > 0.999 |
| Spatial Resolution | ~0.3 mm/pixel at standard working distance |
| Parameter Accuracy | Fv/Fm ±0.005, ΦPSII ±0.01, qP/qN ±0.02, NPQ ±0.1, PIABS ±0.05 |
| Brand | COMECAUSE |
|---|---|
| Model | IN-CL1 |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% at 0.3 µm, 100% ±30% at 0.5 µm and 5.0 µm |
| Accuracy (Particle Concentration) | ±30% at 0.5 µm |
| Repeatability (Relative Standard Deviation) | ≤±10% |
| Zero Count Level | ≤1 count per 5 minutes |
| Self-Cleaning Time | ≤10 min |
| Operating Temperature | 15–35 °C |
| Relative Humidity | 10–85% RH (non-condensing) |
| Display | 7-inch color capacitive touchscreen |
| Data Storage Capacity | Up to 100,000 records |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.2, USB Type-A (driver-free U-disk export) |
| Power Supply | Rechargeable Li-ion battery (16.8 V / 5 Ah, 74 Wh) |
| Battery Runtime | ≥6 hours continuous sampling |
| Charging Time | ≤2 hours |
| Printer | Built-in high-speed thermal printer (selectable channel output) |
| Compliance | GB/T 6167–2007, JJF 1190–2008, ISO 14644-1, Fed Std 209E, Annex 1 of EU GMP (2022), USP <788>, FDA 21 CFR Part 11 (audit trail enabled in platform mode) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-CL2 |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% at 0.3 µm, ≥100% at ≥0.5 µm |
| Zero Count Level | ≤1 count/5 min |
| Self-Cleaning Time | ≤10 min |
| Size Accuracy | ±30% at 0.5 µm and 5.0 µm |
| Concentration Accuracy | ±30% at 0.5 µm |
| Repeatability | ≤±10% CV |
| Operating Environment | 15–35 °C, 10–85% RH (non-condensing) |
| Data Storage Capacity | Up to 100,000 records |
| Display | 7-inch capacitive color touchscreen |
| Power Supply | Internal rechargeable Li-ion battery (16.8 V / 5 Ah, 74 Wh) |
| Battery Runtime | ≥6 h continuous sampling |
| Charging Time | ≤2 h |
| Communication | Wi-Fi 802.11 b/g/n, Bluetooth 4.2, USB Type-A for direct data export |
| Regulatory Compliance | GB/T 6167–2007, JJF 1190–2008, ISO 14644-1, FS-209E, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | IN-CL3 |
| Sampling Flow Rate | 28.3 L/min (1 cfm) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Self-Cleaning Time | ≤10 min |
| Size Accuracy (0.5 & 5.0 µm) | ±30% |
| Concentration Accuracy (0.5 µm) | ±30% |
| Repeatability | ≤±10% |
| Operating Temperature | 15–35 °C |
| Relative Humidity Range | 10–85% RH |
| Data Storage Capacity | 10,000 records |
| Battery Life | ≥6 h (continuous sampling) |
| Power Supply | AC/DC dual-mode, 16.8 V / 15 Ah Li-ion battery |
| Display | 7-inch color capacitive touchscreen |
| Connectivity | Wi-Fi, Bluetooth, USB flash drive support |
| Calibration Standard | JJF 1190–2008 |
| Performance Verification Standard | GB/T 6167–2007 |
| Cleanroom Classification Support | ISO 14644-1, FS209E, GMP (static/dynamic) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | IN-CTS3 |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Inspection Method | Pulse-Echo & Through-Transmission |
| Waveform Mode | Continuous Wave (CW) and Pulsed Wave (PW) |
| Application Sectors | Aerospace, Power Generation, Petrochemical, Pressure Vessel, Rail Transit, Automotive, Structural Steel |
| Scan Range | 0–10000 mm |
| Gain Adjustment | 0–110 dB |
| Vertical Linearity Error | ≤2.5% |
| Horizontal Linearity Error | ≤0.1% |
| Dynamic Range | ≥32 dB |
| Resolution | ≥40 dB |
| Probe Types Supported | Single-Crystal & Dual-Crystal |
| Frequency Range | 0.5–20 MHz |
| Sensitivity Margin | ≥60 dB (200 mm depth, Ø2 mm flat-bottom hole) |
| Material Sound Velocity Range | 1000–9999 m/s |
| Echo Suppression | 0–80% |
| Operating Temperature | −27°C to +70°C |
| Dimensions | 240 × 160 × 40 mm |
| Weight | 1.3 kg |
| A-scan Storage Capacity | 980 frames |
| Channel Memory | 16 user-configurable inspection channels |
| DAC/AVG Curve Generation | Automatic (via standard test blocks) |
| Weld Diagram Modes | I-, V-, U-, and X-type schematic overlays |
| Defect Sizing | Equivalent reflector diameter (φ) calculation |
| Data Interface | USB 2.0 for PC connectivity and report export |
| Display | High-brightness TFT LCD, sunlight-readable |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-D1 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Potential Resolution (display) | 0.1 mV |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Repeatability | ≤0.2% |
| Maximum Error | ≤±1.5% |
| Burette Options | 10 mL (±5 µL), 20 mL (±10 µL) |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Data Storage Capacity | 100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Potential Display Resolution | 0.1 mV |
| Compliance | JJG 814–2015 Class 0.05 (Max. Indication Error: ±1.5% |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0.00 µS/cm–2000 mS/cm |
| Temperature Range | −5 to 105 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2 °C |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Data Storage | ≥100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-D3 |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal Laboratory Use |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Titration Accuracy | ±5 µL (for 10 mL burette) |
| Potential Basic Error | ±0.25 ‰/FS |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Data Storage Capacity | 100,000 records |
| Operating System | Android 10 |
| Display | 7-inch capacitive touchscreen |
| Connectivity | USB, Wi-Fi, Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Model | IN-D4 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Potential Measurement Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.25 ‰ of full scale |
| Potential Stability | ±0.3 mV / 3 h |
| Titration Precision | ±5 µL (for 10 mL burette) |
| Titration Resolution | 0.1 mV |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| Conductivity Range | 0.00 µS/cm – 2000 mS/cm |
| Conductivity Accuracy | ±1.0 % FS |
| Temperature Range | −5 °C to +105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Display | 7-inch Android 10 touchscreen |
| Data Storage | 100,000 records |
| Connectivity | USB / Wi-Fi / Ethernet |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Brand | COMECAUSE |
|---|---|
| Model | IN-DFZ |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Torque Range | 0–10 N·m |
| Weight | 300 g |
| Dimensions | As per technical documentation |
| Power Supply | AC 200–240 V, 50/60 Hz |
| Motor Power | ≤250 W |
| Mixer Shaft Speed | 63 ± 2 rpm |
| Speed Ratio (Fast/Slow Blades) | 1.50 ± 0.01:1 |
| Bowl Capacity | 300 g |
| Torque Sensor Accuracy | ≥0.5% FS |
| Temperature Control | 30 ± 0.2 °C (via integrated water bath) |
| Water Addition Precision | ±0.2 mL |
| Standard Compliance | GB/T 14614–2019, GB/T 35943–2018 |
| Data Export Format | CSV/Excel-compatible |
| Safety Features | Overload protection, bowl interlock, emergency stop |
| Brand | COMECAUSE |
|---|---|
| Model | IN-DK1 |
| Type | Portable Headspace Gas Analyzer |
| Measurement Principle | Electrochemical O₂ Sensor (Primary), Optional NDIR CO₂ Sensor |
| Gas Targets | O₂ (0–30% vol), CO₂ (0–100% vol, optional) |
| Resolution | 0.01% vol |
| Accuracy | ±0.2% vol (O₂, 0–50%), ±2% (O₂, 50–100%) |
| Response Time | ≤15 s (O₂), ≤20 s (CO₂) |
| Sampling Volume | <5 mL (O₂), <15 mL (CO₂) |
| Pressure Range | 700–1500 mbar (abs.) |
| Calibration | Two-point (zero/span) |
| Data Storage | 2000 entries (circular buffer) |
| Interface | USB 2.0 |
| Power | Rechargeable 6800 mAh Li-ion battery |
| Operating Temperature | 0–40 °C |
| Dimensions | 180 × 106 × 80 mm |
| Weight | 450 g |
| Compliance | Designed per JJG 365–2008 (Chinese Metrological Verification Regulation for Electrochemical Oxygen Analyzers) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-DK2 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Gas Detection | O₂ (0–30% vol, resolution 0.01% vol, accuracy ≤±0.2% in 0–50%, ≤±2% in 50–100%), CO₂ (0–100% vol, resolution 0.01% vol, accuracy ≤±2% in 0–50%, ≤±3% in 50–100%) |
| Sensor Types | Electrochemical (O₂), NDIR Infrared (CO₂) |
| Sample Volume | <5 mL (O₂), <15 mL (CO₂) |
| Response Time | ≤15 s (O₂), ≤20 s (CO₂) |
| Pressure Range | 700–1500 mbar (abs.) |
| Sampling Method | Integrated diaphragm pump with sterile piercing needle |
| Data Storage | 2000 records (circular buffer) |
| Battery | 6800 mAh Li-ion, operating time >12 h |
| Dimensions | 180 × 106 × 80 mm |
| Weight | 450 g |
| Operating Temperature | 0–40 °C |
| Calibration | Two-point (zero/span) with certified gas standards |
| Compliance Reference | JJG 365–2008 (Chinese metrological verification regulation for electrochemical oxygen analyzers) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-DK3 |
| Type | Portable Headspace Gas Analyzer |
| Measurement Principle | Electrochemical (O₂) & Non-Dispersive Infrared (NDIR, CO₂) |
| Gas Targets | O₂ (0–30% vol), CO₂ (0–100% vol) |
| Resolution | 0.01% vol for both |
| Accuracy | ±0.2% vol (O₂, 0–50%) |
| Response Time | ≤15 s (O₂), ≤20 s (CO₂) |
| Sample Volume | <5 mL (O₂), <15 mL (CO₂) |
| Sampling Method | Integrated diaphragm pump with needle probe |
| Calibration | Two-point (zero/span) using certified gases |
| Pressure Range | 700–1500 mbar (abs.) |
| Data Storage | 2000 records (circular buffer) |
| Interface | USB 2.0 |
| Battery | 6800 mAh Li-ion, >12 h continuous operation |
| Operating Temperature | 0–40 °C |
| Dimensions | 180 × 106 × 80 mm |
| Weight | 450 g |
| Compliance | Designed per JJG 365–2008 (Chinese metrological verification regulation for electrochemical oxygen analyzers) |
| Language Support | Switchable English/Chinese UI |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-DM (High-Configuration) |
| Price | USD 2,680 (approx. ¥19,000) |
| Optical Resolution | 4800 × 9600 dpi |
| Scan Area (Transmissive) | 30 cm × 20 cm |
| Minimum Pixel Size | 0.0053 mm × 0.0026 mm |
| Measurement Accuracy (Length) | ≤ ±0.05 mm |
| Length-to-Width Ratio Error | ≤ ±0.05 |
| Repeatability Error (Morphometrics) | ≤ ±0.02 |
| Error (Head Rice Rate / Broken Rice Rate) | ≤ ±1.0% |
| Repeatability Error (Head/Broken Rates) | ≤ ±0.25% |
| Grain Counting Accuracy | ≥ 99% (≥ 100% after manual correction) |
| Compatible Grain Size Range | 0.25–20 mm |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-DM |
| Price | USD 2,100 (approx.) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-DM |
| Optical Resolution | 4800 × 9600 dpi |
| Scan Area (Transmissive) | 30 cm × 20 cm |
| Minimum Pixel Size | 0.0053 mm × 0.0026 mm |
| Measurement Accuracy (Length) | ≤ ±0.05 mm |
| Length-to-Width Ratio Accuracy | ≤ ±0.05 |
| Repeatability Error (Morphometric Parameters) | ≤ ±0.02 |
| Whole-Milled Kernel Rate & Broken Kernel Rate Accuracy | ≤ ±1.0% |
| Repeatability Error (Rate Metrics) | ≤ ±0.25% |
| Grain Counting Accuracy (Auto) | ≥ 99%, 100% after manual correction |
| Detectable Grain Size Range | 0.25–20 mm |
| Compliance Standards | GB/T 1350, GB/T 17891, GB 1354–2018, NY/T 2334–2013, LS/T 6116–2016, LS/T 3247–2017, GB/T 35881–2018, NY/T 832–2004 |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-DMJ |
| Price | USD 2,600 (approx.) |
| Compliance | GB/T 5502-2018, GB 1354-2018, GB/T 5503-2009 |
| Optical Resolution | 4800 × 9600 dpi |
| Pixel Size | ≥0.005 mm × 0.0026 mm |
| Scan Area (Reflective) | 355.6 mm × 215.9 mm |
| Sample Capacity | 1–2000 grains (≤18 g) |
| Analysis Time | ≤90 s per batch |
| Detection Principle | Dual-wavelength chromogenic staining + high-resolution digital image segmentation & morphometric analysis |
| Software Platform | Windows-based proprietary analysis suite with audit trail, Excel export, cloud synchronization, and barcode integration |
| Environmental Operating Range | 10–30 °C, RH ≤85%, stable horizontal surface, no strong ambient light or EMI |
| Power Supply | 220 V ±10%, 50 Hz |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | IN-DMJ |
| Price | USD 2,600 (approx.) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | IN-FT300 |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 20–300 W |
| Sample Volume Capacity | 0.1–300 mL (with interchangeable titanium alloy probes) |
| Pulse Control Resolution | 0.1 s (on/off/total time) |
| Temperature Monitoring Range | 0–99.9 °C (contact-type sensor) |
| Display | 10.1″ HD capacitive touchscreen |
| Probe Material | TC4 titanium alloy |
| Transducer Housing | Aerospace-grade magnesium-aluminum alloy |
| Data Storage | 256 programmable protocols |
| Compliance | CE-marked design principles |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-G10 |
| Price | USD 1,200 (FOB) |
| Principle | Quantum Sensor–Based Canopy Radiometric Analysis |
| Type | Portable Handheld Instrument |
| PAR Wavelength Range | 400–700 nm |
| PAR Measurement Range (Probe) | 0–2700 μmol·m⁻²·s⁻¹ |
| Resolution | 1 μmol·m⁻²·s⁻¹ |
| Integrated PAR Sensors | 80 (linear array probe), 1 (external reference sensor) |
| Probe Length | 100 cm |
| Total Unit Length | 128 cm |
| Cable Length (External Sensor) | 2 m |
| Sampling Interval | 1–60 min (programmable) |
| Max. Auto-Sampling Events | 999 |
| Data Storage | 16 GB Internal SD Card (removable, standard microSDHC) |
| Display | Dual-language (English/Chinese) LCD with one-touch toggle |
| Power Supply | Two 18650 Li-ion batteries (3500 mAh each) |
| Charging Interface | DC 5 V via USB-C |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 0–100 % RH (non-condensing) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-G10 |
| Measurement Principle | Photosynthetically Active Radiation (PAR) Interception Method |
| Instrument Type | Handheld Portable |
| Spectral Range | 400–700 nm |
| PAR Sensor Resolution | 1 μmol·m⁻²·s⁻¹ |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 0–100% RH |
| Power Supply | Dual 18650 Li-ion Batteries (3500 mAh each) |
| Charging Interface | USB-C, 5 V DC |
| Probe Length | 100 cm |
| Total Unit Length | 128 cm |
| Cable Length (External Sensor) | 2 m |
| Data Storage | 16 GB Internal + Standard SD Card Slot |
| Connectivity | Bluetooth 5.0, Optional Wi-Fi Module |
| Display | High-Brightness Touchscreen with Dual-Language UI (English/Chinese) |
| Auto-Measurement Interval | 1–60 min (up to 999 cycles) |
| GPS Integration | Built-in GNSS Receiver for Georeferenced LAI Mapping |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-G100 |
| Price | USD 8,100 (FOB) |
| Imaging Sensor | 150° fisheye lens (2592 × 1944 resolution) |
| PAR Spectral Range | 400–700 nm |
| PAR Measurement Range | 0–2000 µmol·m⁻²·s⁻¹ |
| Field Coverage Radius | 30 m |
| Lens Height Adjustment Range | 0.5–4 m (customizable) |
| Data Acquisition Interval | 0.5–72 h (user-configurable, daylight-activated via GPS) |
| Local Storage | 20 GB (≥180 days of image + metadata) |
| Power Supply | 200 W solar panel + 130 Ah gel battery (dual-mode: AC 220 V optional) |
| Operating Temperature | −10 °C to +55 °C |
| Display | 10-inch capacitive touchscreen (multi-language UI: English/Chinese) |
| Cloud Platform | Secure 4G-enabled agricultural data hub with audit-ready export (CSV, PNG, JSON) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-G20 |
| Principle | Hemispherical Image Analysis (Fisheye Photography + PAR Sensing) |
| Type | Portable Field Instrument |
| Field of View | 150° Fisheye Lens |
| PAR Spectral Range | 400–700 nm |
| PAR Measurement Range | 0–2000 μmol·m⁻²·s⁻¹ |
| Angular Resolution | Zenith Angle 0°–75° (10 zones), Azimuth 0°–360° (10 zones) |
| Image Sensor Resolution | 768 × 494 pixels |
| Probe Dimensions | Ø60 mm × 100 mm |
| Weight | 500 g (probe only) |
| Operating Temperature | 0–55 °C |
| Interface | USB 2.0 |
| GPS Integration | Real-time geotagging (latitude/longitude) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-G20 |
| Principle | Hemispherical Digital Image Analysis |
| Form Factor | Handheld Portable System |
| PAR Sensor Range | 400–700 nm |
| Photosynthetic Photon Flux Density (PPFD) Measurement Range | 0–2000 μmol·m⁻²·s⁻¹ |
| Field of View | 150° Fisheye Lens |
| Image Resolution | 768 × 494 pixels |
| Zenith Angle Coverage | 0°–75° (divisible into 10 zones) |
| Azimuthal Coverage | 0°–360° (divisible into 10 zones) |
| Operating Temperature | 0–55 °C |
| Probe Dimensions | Ø60 mm × 100 mm |
| Weight (probe only) | 500 g |
| Interface | USB 2.0 |
| GPS Integration | Built-in geotagging with real-time latitude/longitude output |
| Data Cloud Sync | Encrypted upload to proprietary agricultural cloud platform |
| Brand | COMECAUSE |
|---|---|
| Model | IN-G20 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Principle | Hemispherical Image Analysis (Fisheye Lens + CCD) |
| Instrument Type | Handheld Portable |
| PAR Spectral Range | 400–700 nm |
| PAR Measurement Range | 0–2000 μmol·m⁻²·s⁻¹ |
| Field of View | 150° (Hemispherical) |
| Image Resolution | 768 × 494 pixels |
| Zenith Angle Partitioning | 0°–75° (10 zones) |
| Azimuthal Partitioning | 0°–360° (10 zones) |
| Probe Dimensions | Ø6 cm × 10 cm |
| Weight | 500 g (probe only, excluding laptop) |
| Operating Temperature | 0–55 °C |
| Interface | USB |
| GPS Integration | Built-in Real-time Geotagging |
| Software | COMECAUSE Canopy Analysis System v3.x |