CoMetro
Filter
Showing 1–30 of 97 results
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000 PCR |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000 Photochemical Derivatization System |
| Light Source | Cold UV LED |
| Output Power | 8 mW |
| Wavelength | 254 nm |
| Reactor Design | Köhler Illumination Optics |
| Maximum Flow Rate | 3 mL/min |
| Cooling Method | Forced-Air Temperature Control |
| Derivatization Type | Post-Column, Reagent-Free Photochemical Activation |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000 Photochemical Derivatization System |
| Derivatization Flow Rate | 3 mL/min |
| Reaction Coil Material | Stainless Steel |
| Light Source | Cold UV Lamp |
| Wavelength | 254 nm |
| Output Power | 8 mW |
| Illumination Geometry | Köhler Illumination |
| Temperature Control | Forced-Air Cooling |
| Application | Post-Column Derivatization for HPLC |
| Brand | CoMetro |
|---|---|
| Model | CoMetro 6000 |
| Temperature Range | 10–150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Maximum Pressure | 4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CoMetro 6000 Series |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | CoMetro 6000 Series |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000 Series |
| Derivatization Reagent Flow Rate | 0.001–5 mL/min or 0.01–10 mL/min |
| Reaction Coil Material | PEEK |
| Temperature Control Range | Ambient +10 °C to 150 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Maximum Pressure | 4000 PSI |
| System Fluidic Path | Full PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000 Series |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | Full PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000 |
| Temperature Range | Room Temperature +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Brand | CoMetro |
|---|---|
| Model | 6000 Single PCR |
| Temperature Range | 10–150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Flow Path | Full-Peek |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Pressure Range | 0–4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| [Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000 Series |
| Temperature Range | 10–150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Reactor Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Max Pressure | 4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD] |
| Brand | CoMetro |
|---|---|
| Model | 6000LDS |
| Flow Rate | 0.001–80 mL/min (selectable ranges) |
| Maximum Pressure | 6000 psi (stainless steel pump head), 5000 psi (PEEK pump head) |
| Pressure Accuracy | ±1% |
| Flow Precision | ≤0.2% RSD |
| Display | Real-time flow rate, system pressure, upper/lower pressure limits |
| Control Interface | Front-panel keypad + RS232 digital communication |
| Power Supply | 115/230 V, 50/60 Hz |
| Fluid Path Materials | Optional PEEK or 316 stainless steel |
| Integrated Features | Low-dead-volume pulsation dampener, fast-fill priming mechanism, passive check valves, built-in bypass valve, self-cleaning module |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000PCR |
| Temperature Range | 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Max Pressure | 4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | Koller-Ring |
| Derivatization Flow Rate | 3 mL/min |
| Light Source | Cold UV LED |
| Wavelength | 254 nm |
| Output Power | 8 mW |
| Reactor Type | Koller-Ring Optical Cell |
| Temperature Control | Forced-Air Cooling |
| Operating Temperature | Ambient |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000PER Photochemical Derivatization System |
| Derivatization Flow Rate | 3 mL/min |
| Light Source | Cold UV LED |
| Output Power | 8 mW |
| Wavelength | 254 nm |
| Reactor Type | Köhler Illumination Chamber |
| Cooling Method | Forced Air Cooling |
| Compliance | Designed for HPLC post-column derivatization per ASTM D7577 (aflatoxins) and USP <1092> (derivatization validation) |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000PER |
| Temperature Control | Ambient (Forced Air Cooling) |
| Derivatization Reagent Flow Rate | 0–3 mL/min |
| Reaction Coil Material | Stainless Steel |
| Light Source | Cold UV Lamp |
| Wavelength | 254 nm |
| Output Power | 8 mW |
| Optical Design | Köhler Illumination |
| Max. Flow Rate | 3 mL/min |
| Compliance | Designed for HPLC Post-Column Derivatization per ASTM D7891 & USP <1092> |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | 6000PER Photochemical Derivatization Unit |
| Light Source | Cold UV LED |
| Output Power | 8 mW |
| Wavelength | 254 nm |
| Maximum Flow Rate | 3 mL/min |
| Reaction Chamber | Köhler Illumination Design |
| Temperature Control | Forced-Air Cooling |
| Operating Temperature Range | Up to 100 °C |
| Derivatization Type | Post-Column, Reagent-Free Photochemical Activation |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000PER Photochemical |
| Derivatization Flow Rate | 3 mL/min |
| Reaction Coil Material | Stainless Steel |
| Light Source | Cold Cathode UV Lamp |
| Wavelength | 254 nm |
| Output Power | 8 mW |
| Illumination Geometry | Köhler Illumination |
| Temperature Control | Forced-Air Cooling |
| Compliance | Designed for ASTM D7112, USP <232>/<233>, and ICH Q2(R2) compliant workflows |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | 6000PER |
| Light Source | Cold UV LED |
| Output Power | 8 mW |
| Wavelength | 254 nm |
| Reactor Design | Köhler Illumination Optics |
| Max Flow Rate | 3 mL/min |
| Cooling Method | Forced Air Convection |
| Derivatization Principle | In-line UV-mediated photochemical activation |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model Series | 6000PER |
| Derivatization Flow Rate | 3 mL/min |
| Light Source | Cold UV Lamp (254 nm, 8 mW output) |
| Reaction Coil | Stainless Steel |
| Temperature Control | Forced-Air Cooling |
| Compliance | Designed for HPLC-integrated post-column derivatization |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CF-2 |
| Instrument Type | Mixed-Mode Fraction Collector |
| Collection Mode | Drop Counting |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lbs) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Drop Range | 1–9999 drops (increment: 1 drop) |
| Time Range | 6 sec–999 min 59 sec (increment: 1 sec) |
| Tube Switching Time | ≤0.35 sec (for 12/13 mm tubes) |
| Max. Capacity | 174 fractions (with standard tube rack) |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Time-based, Droplet-count-based |
| Max Capacity | 174 Tubes (12/13 mm) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Liquid Chromatography Fraction Collector |
| Collection Mode | Volume-Based |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lbs) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Collection Range | 1–9999 drops (1-drop increment) |
| Timer Range | 6 sec–999 min 59 sec (1-sec increment) |
| Max. Tube Capacity | 174 × 12/13 mm tubes (with standard rack) |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Stepwise Fraction Collector |
| Collection Modes | Time-based, Drop-count-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12–13 mm diameter) or 42 flash vials (28 mm) |
| Tube Switching Time | ≤0.35 s (for 12/13 mm tubes) |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Construction | Anodized aluminum frame and stainless-steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Mode | Volume-Based |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (10 lbs) |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Operating Temperature | 0–40 °C |
| Droplet Count Range | 1–9999 (incremental by 1) |
| Time-Based Collection Range | 6 sec–999 min 59 sec (incremental by 1 sec) |
| Tube Switching Time | ≤0.35 sec (for 12/13 mm diameter tubes) |
| Max. Fraction Capacity | 174 tubes (with standard rack) |
| Construction | Anodized aluminum frame and stainless steel components |
| Compatibility | Integrates with UV detectors (e.g., Spectra/Chrom 280), peak fractionation modules, and multi-column systems via optional 4-column adapter |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Drop Count, Time, Optional Volume (via Flow Sensor Integration) |
| Max Capacity | 174 Tubes (12/13 mm) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power | 115 VAC or 230 VAC, 50/60 Hz |
| Power Consumption | <10 W |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lb) |
| Compliance | CE-marked |
| Material | Anodized Aluminum Frame + Stainless Steel Components |
| Optional Accessories | 3-Way Split Valve (Cat. #124849), High-Flow 3-Way Valve (Cat. #124838), 2-Way Shut-Off Valve (Cat. #124848), 4-Column Adapter (Cat. #124876), Extension Mounting Bracket (Cat. #124874), Acrylic Dust Cover (Cat. #124858), Multiple Tube Rack Configurations (Cat. #124853–#124856) |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Drop-count, Time-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12–13 mm diameter) |
| Tube Switching Time | ≤0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Input | 115 VAC or 230 VAC, 50/60 Hz |
| Power Consumption | <10 W |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Compliance | CE-marked |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Time-Based, Droplet-Count-Based, Volume-Based (via flow rate calibration) |
| Max Capacity | 174 tubes (12/13 mm diameter) or 42 flash vials (28 mm) |
| Tube Switching Time | ≤0.35 s (for 12/13 mm tubes) |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Power Consumption | <10 W |
| Dimensions (W×D×H) | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lb) |
| Material | Anodized aluminum frame with stainless steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Time-based, Drop-count-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12/13 mm diameter) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Input | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Construction | Anodized aluminum frame and stainless steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CF-2 |
| Instrument Type | Mixed-Mode Fraction Collector |
| Collection Mode | Drop Counting |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (10 lbs) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Drop Range | 1–9999 drops (increment: 1 drop) |
| Time Range | 6 sec–999 min 59 sec (increment: 1 sec) |
| Tube Switching Time | ≤0.35 sec (for 12/13 mm diameter tubes) |
| Tube Capacity | Up to 174 positions (with standard rack) |
| Compliance | CE-marked, RoHS-compliant, compatible with GLP/GMP workflows requiring audit-trail-capable chromatography systems |