Cubic
Filter
Showing 31–60 of 113 results
| Brand | Cubic |
|---|---|
| Model | CFG-1000 |
| Origin | Hubei, China |
| Dimensions | 100 × 100 × 100 mm |
| Weight | 477 g |
| Power Input | DC 5 V via USB Type-C |
| Max Current Draw | ≤1 A |
| Operating Temp | −20 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temp | −20 °C to +50 °C (non-condensing) |
| Fragrance Cartridge Slots | 3 |
| Diffusion Modes | 3 adjustable intensity levels |
| Sealed Cartridge Design | Yes |
| Estimated Cartridge Lifespan | Up to 270 days |
| Diffusion Method | Fan-assisted solid-phase aroma dispersion |
| Brand | Cubic |
|---|---|
| Model | CM01 |
| Type | Portable CO₂ Monitor |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Sensing |
| Range | 400–5000 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Operating Temperature | −10 °C to 50 °C, 0–95% RH (non-condensing) |
| Storage Temperature | −20 °C to 60 °C, 0–95% RH (non-condensing) |
| Power Supply | DC 5 V (USB-powered) |
| Display | Digital LCD |
| Dimensions | 101.9 × 26.4 × 16 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1106SD |
| Price | USD 42 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5000 ppm CO₂ (standard configuration) |
| Accuracy | ±(50 ppm + 3% of reading) @ 25°C, 1 atm |
| Response Time (T90) | < 90 s |
| Operating Temperature | –10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 5.0 VDC ±5% |
| Average Current Consumption | < 25 mA |
| Output Interface | Analog (0.4–2.0 V DC proportional to CO₂ concentration) + UART (TTL level) |
| Warm-up Time | < 60 s |
| Dimensions | 33 × 22 × 18 mm |
| Weight | ~12 g |
| Lifetime | > 15 years (typical sensor core) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1106SL-N |
| Detection Principle | NDIR (Non-Dispersive Infrared) |
| Measurement Range | 0–5000 ppm CO₂ |
| Accuracy | ±(50 ppm + 5% of reading) at 25°C ± 2°C |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −30°C to +70°C |
| Supply Voltage | DC 5 V ± 0.1 V (ripple < 50 mV) |
| Average Current Consumption | 12 µA @ 5-min measurement interval |
| Output Interface | UART TTL (3.3 V / 5 V compatible) |
| Dimensions (L×W×H) | 33 × 19.7 × 9.4 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1107 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5000 ppm (customizable up to 12,000 ppm) |
| Warm-up Time | ≤30 s |
| Data Update Rate | 1 Hz |
| Accuracy | ±(30 ppm + 3% of reading) at 25°C±2°C, 50%±10% RH |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V |
| Average Current Consumption | <70 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V), I²C, PWM |
| Dimensions (L×W×H) | 33 mm × 21.7 mm × 10 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CM1109 |
| Price | USD 68.50 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 400–5000 ppm (extendable to 10,000 ppm) |
| Warm-up Time | ≤30 s |
| Data Update Rate | 1 Hz |
| Accuracy | ±(50 ppm + 5% of reading) for residential use |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V |
| Average Current Consumption | <45 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V logic), I²C, PWM |
| Dimensions (L×W×H) | 33 × 20.3 × 11.4 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | CM2200 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| ETCO₂ Range | 0–150 mmHg (0–20 kPa at 760 mmHg) |
| ETCO₂ Resolution | 0.1 mmHg (0–49 mmHg), 0.2 mmHg (50–150 mmHg) |
| ETCO₂ Accuracy | ±2 mmHg (0–40 mmHg), ±5% of reading (41–70 mmHg), ±8% of reading (71–100 mmHg), ±10% of reading (100–150 mmHg) |
| Respiratory Rate Range | 2–150 breaths/min |
| Respiratory Rate Accuracy | ±1 breath/min |
| Communication Interface | TTL / RS-232 |
| Operating Conditions | 0°C–45°C, 10–90% RH (non-condensing) |
| Storage Conditions | −40°C–70°C, <90% RH (non-condensing) |
| Dimensions | 52 × 23 × 36 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CM2201 |
| Price | USD 700 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–150 mmHg |
| Resolution | 0.1 mmHg |
| Accuracy | ±2 mmHg (0–40 mmHg), ±5% of reading (41–70 mmHg), ±8% (71–100 mmHg), ±10% (100–150 mmHg) |
| Respiratory Rate Range | 0–150 BPM |
| Respiratory Rate Accuracy | ±1 BPM |
| Short-Term Drift | ≤0.8 mmHg (4 h) |
| Long-Term Drift | Maintains Specified Accuracy over 120 h |
| Supply Voltage | 5.00 V ±5% |
| Avg. Current Draw | <120 mA |
| Peak Current | <250 mA |
| Warm-up Time to Display | ≤15 s |
| Time to Full-Spec Accuracy | ≤2 min (at 25°C) |
| Barometric Pressure Compensation | 400–850 mmHg |
| Operating Temp. | 0–45°C, 10–90% RH (non-condensing) |
| Storage Temp. | −40–70°C, <90% RH (non-condensing) |
| Interface | RS232, 19200-N-8-1 |
| Dimensions | 52 × 23 × 36 mm |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ECO-5011 |
| Detection Principle | Electrochemical |
| Target Gas | Carbon Monoxide (CO) |
| Measurement Range | 0–10,000 ppm |
| Output Signal | 1.5–3 nA/ppm |
| Repeatability | ±2% |
| Resolution | 0.5 ppm |
| Response Time (T90) | <60 s |
| Long-Term Output Drift | <2%/month |
| Expected Service Life | 8–10 years |
| Weight | ~12 g |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −20 to +60 °C |
| Relative Humidity | 5–99% RH (non-condensing) |
| Operating Pressure | 0.1 MPa ±10% |
| Bias Voltage | Not required |
| Recommended Load Resistance | 1 kΩ |
| Compliance | UL 2075, UL 2034, EN 50291, RoHS |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FM01 |
| Detection Principle | Electrochemical Sensor |
| Measurement Range | 0–1 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ≤ 0.1 mg/m³: ±0.03 mg/m³ |
| > 0.1 mg/m³ | ±25% of reading |
| Repeatability | < ±3% RSD (typical, per ISO 16000-23) |
| Response Time (T90) | < 60 s |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 15–95% RH (non-condensing) |
| Storage Temperature | −20–50 °C |
| Power Supply | DC 5 V ±0.1 V |
| Current Consumption | ≤ 300 mA |
| Communication Interface | USB-A |
| Dimensions | 101.9 × 26.4 × 16 mm (W × H × D) |
| Compliance | Meets requirements for indoor air quality screening per ISO 16000-23 and GB/T 18883–2022 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2006 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | Carbon Monoxide (CO), Carbon Dioxide (CO₂) |
| CO Range | 0–1000 ppm (1 ppm resolution) |
| CO₂ Range | 0–20 vol.% (0.01 vol.% resolution) |
| CO Detection Limit | 0.5% FS |
| CO₂ Detection Limit | 0.1% FS |
| Linearity Error | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Drift | ≤ ±2% FS / 24 h |
| Response Time (T₉₀) | < 8 s @ 0.7 L/min |
| Sample Flow Rate | 0.2–1.0 L/min |
| Internal Thermostat | 50 °C ±0.5 °C |
| Warm-up Time | < 30 min |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Atmospheric Pressure | 86–115 kPa |
| Power Supply | 12 VDC ±0.2 V |
| Max Power Consumption | 36 W (heating active), < 800 mW (standby) |
| Communication Interface | RS-232 / RS-485 (Modbus RTU protocol) |
| Housing | Modular OEM-grade metal enclosure with integrated optical gas cell |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2050 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | CO, CH4, CO₂ |
| Range | 0–3500 ppm (CO/CH₄), 0–10% vol (CO₂) |
| Resolution | 1 ppm (CO/CH₄), 10 ppm (CO₂) |
| Accuracy | ±1% FS |
| Linearity Error | ≤±1% FS |
| Response Time (T₁₀–T₉₀) | <300 ms @ 1 L/min |
| Zero Drift (30 s) | ≤10 ppm (CO), ≤1% FS (CH₄) |
| Operating Temp. | −10°C to +45°C |
| Humidity | 0–90% RH (non-condensing) |
| Power Supply | +12 V ±10% DC, ≤600 mA |
| Output Interface | RS232 @ 115200 bps, 16 Hz update rate |
| Dimensions | 183 × 65.6 × 70 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2063 |
| Pricing | Available Upon Request |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2501 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measuring Range | 0–100% LEL / 0–5% VOL (expandable to 20% VOL) |
| Accuracy | ±3% LEL |
| Resolution | 0.1% LEL |
| Response Time (T90) | <20 s |
| Startup Time | <5 s |
| Operating Temperature | −25 °C to +55 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Pressure Range | 80–120 kPa |
| Supply Voltage | 3.2–5.5 VDC |
| Current Consumption | <50 mA (@25 °C, 3.3 V) |
| Output Interface | TTL (3 V logic level) |
| Enclosure Rating | IP67 |
| Dimensions | Ø40 mm × 89.5 mm |
| Storage Temp/Humidity | −40 °C to +85 °C / 0–98% RH (non-condensing) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2501-05F |
| Detection Gas | CH₄ |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Range | 0–100% LEL |
| Accuracy | ±5% LEL |
| Resolution | 0.1% LEL |
| Response Time (T90) | <20 s |
| Operating Temperature | −25 °C to +55 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Storage | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Supply Voltage | 3.2 V–5.5 V |
| Output Interface | TTL (3.0 V logic level) |
| Current Consumption | 15 mA |
| Lifetime | ≥10 years |
| Selectivity | Methane-specific, immune to interference from H₂O vapor, CO₂, CO, H₂, hydrocarbons, and particulates |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2501-05F |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | Methane (CH₄) |
| Measurement Range | 0–100% LEL |
| Accuracy | ±5% LEL |
| Resolution | 0.1% LEL |
| Response Time (T90) | <20 s |
| Operating Temperature | −25 °C to +55 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Storage Conditions | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Supply Voltage | 3.2 V–5.5 V DC |
| Output Interface | TTL (3.0 V logic level) |
| Typical Current Consumption | 15 mA |
| Expected Service Life | ≥10 years |
| Selectivity | High specificity to CH₄ |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2502 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | Methane (CH₄) |
| Measurement Range | 0–1000 ppm |
| Accuracy | ±5 ppm + 2% of reading |
| Resolution | 0.1 ppm |
| Warm-up Time | <10 s |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| Supply Voltage | 3.2–5.5 V DC |
| Current Consumption | <100 mA (@25 °C, 3.3 V) |
| Output Interface | TTL (3.3 V logic level) |
| Dimensions | 278 × 97 × 84 mm |
| Storage Conditions | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Selectivity | High (inherent spectral specificity of TDLAS) |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2503-NH₃ |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | NH₃ |
| Measurement Range | 0–50 ppm |
| Accuracy | ±2% FS |
| Response Time (T90) | ≤20 s |
| Measurement Cycle | 1–3600 s |
| Output Interface | RS485 @ 12 V DC |
| Power Supply | 12 V DC |
| Average Power Consumption | ≤1 W |
| IP Rating | IP66 |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 0–100% RH (non-condensing) |
| Atmospheric Pressure | 101 kPa |
| Explosion Protection | UL Class I, Division 2 |
| Design Life | 10 years |
| Application | Livestock Housing Air Quality Monitoring |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2600 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measuring Gas | O₂ |
| Range | 0–100% vol |
| Accuracy | ±0.3% FS |
| Resolution | 0.01% vol |
| Response Time | 100–170 ms (10–90%, at 150–350 mL/min) |
| Warm-up Time | <25 s |
| Operating Temp. | −10 to +50 °C |
| Humidity | 0–95% RH (non-condensing) |
| Output | RS-232 (default), RS-485 (optional), (0–1) V analog |
| Supply Voltage | 12 V ±10% |
| Current Draw | 1.8 A |
| Dimensions | 180 × 60 × 30 mm |
| Lifetime | ≥10 years |
| Optional Dual-Gas Configuration | O₂ + CO₂ (NDIR) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Gasboard-7030 |
| Pricing | Available Upon Request |
| Volume Range | 0–10 L |
| Flow Rate Range | 0–20 L/s |
| Volume Accuracy | ±0.2% or ±10 mL |
| Volume Resolution | 0.3829 mL |
| Flow Rate Accuracy | ±0.5% or ±25 mL/s |
| BTPS Simulation | 37 °C ±2 °C, 92% RH ±5% |
| Waveform Types | Sine, Square, Trapezoidal, User-Defined |
| Compliance Standards | ATS-24, ATS-26, ISO 23747:2015 (Peak Flow Annexes A & B), EN ISO 26782:2009 (Tests C1–C11, Annexes C12–C13) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-7050 |
| Calibration Volume | 3000 mL |
| Accuracy | ±15 mL |
| Piston Interface Outer Diameter | Φ28 mm |
| Operating Temperature | 15–40 °C |
| Storage Temperature | 0–50 °C |
| Storage Relative Humidity | 10–95 %RH |
| Dimensions (L×W×H) | 590 × 113 × 116.5 mm |
| Weight | 2.5 kg |
| Compliance | JJF 1213–2008 Calibration Specification for Pulmonary Function Instruments |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7500H-OPC |
| Measurement Principle | Ultrasonic Transit-Time Difference |
| Flow Range | 0–5 L/min |
| Accuracy | ±3% FS or ±0.06 L/min (at 5–45 °C) |
| Response Time | ≤0.3 s |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V (ripple ≤50 mV) |
| Current Consumption | ≤35 mA |
| Interface | UART TTL (3.3 V logic level) |
| Dimensions | 80 × 22 × 25 mm (W × H × D) |
| EMC Compliance | Certified per IEC/EN 61000-6-2 & 61000-6-4 |
| Regulatory Approvals | CE, CMC |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-7500K |
| Price | USD 192 (approx. ¥1350) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| O₂ Concentration Range | 0–100% vol (PSA-specific range: 20.5–95.6% vol) |
| O₂ Flow Range | 0–10 L/min |
| O₂ Concentration Accuracy | ±1.5% FS @ (10–45)°C |
| O₂ Flow Accuracy | ±0.2 L/min @ (10–45)°C |
| Resolution | 0.1% vol (O₂), 0.1 L/min (flow) |
| Response Time | ≤1.5 s (concentration), ≤0.3 s (flow) |
| Operating Temp. | 5–50°C, RH ≤95% non-condensing |
| Storage Temp. | −20–60°C, RH ≤95% non-condensing |
| Supply Voltage | DC 4.75–12.5 V, ripple <50 mV |
| Avg. Current Draw | <35 mA |
| Output Interface | UART TTL (5 V logic) |
| Dimensions | 120 × 22 × 13.6 mm (W × H × D) |
| Certifications | CMC, CE, EMC compliant |
| Calibration | Factory-calibrated, lifetime zero-drift compensation, no field recalibration required |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-7500K-OAQ |
| Detection Principle | Ultrasonic Transit-Time Method |
| Flow Range | 0–20 L/min |
| Accuracy | ±3% FS or ±0.2 L/min (at 5–45 °C) |
| Response Time | ≤0.3 s |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20 °C to +60 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V (ripple ≤50 mV) |
| Current Consumption | ≤35 mA |
| Interface | UART TTL (5 V logic) |
| Dimensions | 120 × 30 × 22 mm (W × H × D) |
| Certifications | CMC, CE, EMC compliant |
| Zero Drift | Negligible (factory-compensated) |
| Calibration | Factory-calibrated |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8500D |
| Price | USD 149 (FOB) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| Measurement Range | 20.5–95.6% O₂ (binary gas mixtures) |
| Accuracy | ±3% FS @ (5–45)°C |
| Resolution | 0.1% O₂ |
| Response Time (T₉₀) | ≤10 s |
| Flow Rate Range | 0–80 L/min |
| Operating Temperature | 5–50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20–60°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V |
| Average Current Consumption | <50 mA |
| Output Interface | UART TTL (3.3 V logic level) |
| Dimensions | 60.7 × 26 × 30 mm (L×W×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-8500FS-L240H |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) |
| Flow Range | 0–240 L/min |
| O₂ Concentration Range | 0–100% vol |
| O₂ Accuracy | ±3% F.S. (5–45 °C) |
| Flow Accuracy | ±2% F.S. |
| O₂ Resolution | 0.1% vol |
| Flow Resolution | 0.1 L/min |
| Response Time (O₂) | <0.1 s |
| Response Time (Flow) | <2 ms |
| Operating Temp. | −20 to +55 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temp. | −20 to +70 °C |
| Communication Interfaces | UART-TTL, I²C, Custom Analog Output |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-8500FS-L40 |
| Measurement Principle | Ultrasonic Transit-Time |
| Flow Range | 0–40 L/min |
| O₂ Concentration Range | 0–100% vol |
| O₂ Accuracy | ±3% FS @ 5–45°C |
| Flow Accuracy | ±2% FS |
| O₂ Resolution | 0.1% |
| Flow Resolution | 0.01 L/min |
| O₂ Response Time (T63) | ≤0.1 s (at ≥10 L/min) |
| Flow Response Time (T63) | <10 ms (at ≥10 L/min) |
| Operating Temp | 5–50°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Communication Interfaces | UART-TTL, I²C, Optional Analog Output |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8500V |
| Price | USD 149 (FOB) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| Measurement Range | 20.5–100% O₂ (binary gas mixtures) |
| Accuracy | ±3% FS @ 5–45°C |
| Resolution | 0.1% O₂ |
| Response Time | <15 s (T90) |
| Operating Temp. | 5–50°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Storage Temp. | −20–50°C |
| Supply Voltage | DC 4.75–12.5 V |
| Avg. Current Draw | <35 mA |
| Output Signal | 0–2500 mV analog |
| Dimensions | 46 × 29.3 × 29.3 mm (L×W×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-8500Z |
| Detection Principle | Zirconia Electrochemical |
| Measurement Range | 0.1–25.0 vol.% O₂ |
| Accuracy | ±2% FS |
| Resolution | 0.01% O₂ |
| Response Time | <1 s |
| Operating Temperature | 10–50 °C |
| Operating Humidity | 5–85% RH (non-condensing) |
| Storage Conditions | −20–60 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 12 V ±0.5 V |
| Output Interface | UART TTL (3.3 V logic level) |
| Dimensions | 70 × 40 × 15.3 mm (W×H×D) |
| Surface Temperature Limit | <150 °C (internal sensor element up to <350 °C) |
| Inlet Flow Mode | Free Diffusion |
| Cross-Sensitivity | Negligible (zirconia-selective for O₂) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GLDS-SF6 |
| Price | USD 420 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | Sulfur Hexafluoride (SF6) |
| Measurement Range | 0–1500 ppm |
| Alarm Threshold | Adjustable (Default: 1000 ppm) |
| Resolution | 1 ppm |
| Accuracy | ±2% FS @ 25°C |
| Repeatability | ≤±1% FS |
| Response Time (T90) | <30 s (Diffusion Mode) |
| Warm-up Time | <15 s |
| Operating Temperature | −20 to +60°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| IP Rating | IP54 |
| Expected Service Life | ≥10 years |
| Dimensions | 63.2 × 38.5 × 19.23 mm |
| Compliance | DLT 1555–2016 |