| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaField Pro |
| Spectral Range | 400–2500 nm (configurable by variant) |
| Spectral Resolution | 2.8–10 nm |
| Spatial Resolution | Up to 640 × 700 pixels (spatial × spectral) |
| FOV | 18°–24° (lens-dependent) |
| IFOV | ≤ 0.5 mrad (with standard 23–30 mm lenses) |
| Frame Rate | 4–8 s per hyperspectral cube |
| Detector Types | CCD, InGaAs, T2SL |
| Dynamic Range | 12–14 bits |
| Interface | USB 3.0 / GigE / USB 2.0 |
| Weight | 3–8.5 kg |
| Integrated Battery | 80–120 Wh (≥2 h operation) |
| Onboard Processing | ARM-based real-time analysis engine |
| Wireless Control | Wi-Fi (Android/iOS/iPadOS) |
| Data Output Format | ENVI-compatible .hdr/.bil, Evince, SpecSight-ready |
| Calibration | Radiometric, reflectance, flat-field, lens distortion, and non-uniformity correction |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GaiaField-ImgFluo |
| Spectral Range | 670–780 nm (extendable to 650–800 nm) |
| Spectral Resolution | 0.3–0.4 nm |
| Spectral Sampling Interval | 0.1 nm |
| Number of Spectral Bands | 100–1000 |
| Peak SNR | >1000:1 |
| Slit Width | 30 µm |
| Lens | 25 mm Fixed-Focal-Length |
| Spatial Resolution | ≥1200 × 1000 pixels |
| Frame Rate | 1–100 fps |
| Interface | USB 3.0 |
| Weight | <2.27 kg |
| Imaging Mode | Push-broom |
| Deployment Platform | Ground-based (tripod-mounted or vehicle-integrated), compatible with UAV integration via optional gimbal and power interface |
| Cooling | Thermoelectrically cooled or uncooled sCMOS sensor |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Beijing, China |
| Model | GaiaMicro-G |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm |
| Imaging Principle | Push-broom scanning |
| Optical Configuration | Transmission (visible–NIR) and semi-reflective (NIR) |
| Detector Type | CCD/SCMOS/InGaAs |
| Spatial Scanning | Motorized XY precision translation stage |
| Numerical Aperture | F/2.8 (GaiaMicro-G-V10-LU) |
| Slit Size | 30 µm × 9.6 mm |
| Pixel Array | 1392 × 1040 (spatial × spectral) |
| Spectral Channels | 256 (240 effective) |
| Data Depth | 14-bit |
| Interface | USB 2.0 |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GaiaSorter |
| Price | USD 21,000 (FOB) |
| Operating Principle | Push-broom Hyperspectral Imaging |
| Imaging Mode | 3D Data Cube Acquisition |
| Deployment | Benchtop & Airborne-Compatible |
| Spectral Range | 350–2500 nm (configurable bands: 400–1000 nm, 900–1700 nm, 1000–2500 nm) |
| Spectral Resolution | ≤2.8 nm (FWHM) |
| Spatial Resolution (IFOV) | 30 µm / 50 µm (selectable via optics) |
| Detector Resolution | 1392 × 1040 pixels |
| Field of View (TFOV) | 20° |
| Frame Rate | 25–120 fps |
| Illumination Uniformity | ≥90% |
| Sample Chamber Max Dimensions | 300 × 300 × 200 mm |
| Working Distance Adjustment Range | 180–600 mm (dependent on sample height) |
| Power Input | AC 220 V ±10% |
| Light Source | DC 12 V adjustable-intensity uniform LED array (~200 W total) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Model | GaiaField |
| Operating Principle | Push-broom |
| Imaging Mode | 3D spatial-spectral data cube |
| Deployment | Ground-based |
| Spectral Range | 400–1000 nm (visible to near-infrared) |
| Spectral Resolution | <3 nm (VIS), ≤5 nm (NIR) |
| Spatial Resolution (IFOV) | Configurable via interchangeable lenses |
| Field of View (TFOV) | Lens-dependent |
| Frame Rate | Up to 120 fps (at full resolution, system-limited) |
| Battery Life | >4 hours continuous operation |
| Environmental Rating | IP5X dust resistant, IP1X water resistant |
| Interface | USB 3.0 |
| Data Format | ENVI-compatible BIL/BIP, TIFF, and raw binary |
| OS Compatibility | Windows 7/8/10 (32- & 64-bit) |
| Calibration | Radiometric, reflectance, flat-field, lens distortion, and non-uniformity correction |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaMicro-G |
| Spectral Range | 400–1000 nm (Visible-NIR) / 900–1700 nm (NIR) |
| Spectral Resolution | 2.8–5.0 nm |
| Spatial Resolution | Configurable via interchangeable infinity-corrected objectives (5×–100×) |
| Numerical Aperture | F/2.0–F/2.8 |
| Detector | CCD / sCMOS / InGaAs |
| Pixel Array | Up to 2048 × 2048 (spatial × spectral) |
| Bit Depth | 14–16 bits |
| Interface | USB 2.0 / USB 3.0 / GigE |
| Imaging Mode | Push-broom scanning with motorized XY stage |
| FOV & IFOV | Objective-dependent (e.g., 10× objective: ~1.0 mm FOV, ~0.5 µm IFOV at diffraction limit) |
| Frame Rate | Variable (up to 60 fps for snapshot LCTF variants |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaSky-mini2-VN |
| Imaging Principle | Push-broom scanning |
| Platform Compatibility | Rotary-wing UAVs (e.g., DJI M600 Pro, S1000+), airships, helicopters |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm (at 30 µm slit width) |
| Numerical Aperture | f/2.8 |
| Sensor | Sony ICX674 CCD |
| Pixel Pitch | 4.54 µm |
| Output Bit Depth | 14-bit |
| Interface | USB 3.0 |
| Operating Voltage | 12–19 V DC |
| Power Consumption | 45 W |
| Image Resolution | 960 × 1040 pixels |
| Spatial Sampling (IFOV) | 0.16 m @ 300 m AGL, 17 mm lens |
| Horizontal FOV | 28.7° (@17 mm), 26.7° (@18.5 mm), 21.5° (@23 mm) |
| Ground Coverage Width | 154 m (@17 mm, 300 m) |
| Scan Rate | 160 line images/s |
| Weight | 1.5 kg (integrated camera + controller) |
| Storage | 240 GB SSD |
| Mounting Envelope | ≥330 × 200 × 260 mm (H×W×D) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GaiaSorter-Dual |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm |
| Spatial Resolution (IFOV) | 30 µm and 50 µm |
| Field of View (TFOV) | 20° |
| Imaging Resolution | 1392 × 1040 pixels |
| Frame Rate | 25–120 fps |
| Imaging Modality | 3D Scanning |
| Operational Mode | Airborne-Compatible Benchtop Configuration |
| Power Input | AC 220 V ±10% / DC 12 V |
| Total System Power Consumption | ~500 W |
| Sample Chamber Max Dimensions | 300 × 300 × 100 mm |
| Working Distance Adjustment Range | 100–600 mm |
| Scan Travel | 800 mm |
| Output Interfaces | USB, Ethernet, RS-232 |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | GaiaTracer |
| Imaging Modality | Hyperspectral (Push-broom & Tunable Filter variants) |
| Deployment | Benchtop Laboratory |
| Spectral Range | 250–2500 nm (configurable by variant) |
| Spectral Resolution | 8–20 nm (FWHM, wavelength-dependent) |
| Spatial Resolution | ≤100 µm at 300 mm working distance |
| Field of View (TFOV) | ±7° |
| Instantaneous Field of View (IFOV) | <0.1 mrad |
| Frame Rate | 22–25 fps (GigE data interface) |
| Optical Interface | USB 2.0 (control), GigE (image data) |
| Illumination | Dual 300 W adjustable broadband source (VIS–SWIR), UV optional |
| Sample Stage | Motorized Z-axis (0–800 mm), X/Y translation (300 mm travel), tilt/height-adjustable line source |
| Compliance | Designed for ISO/IEC 17025-aligned forensic laboratories |
| Software | Proprietary acquisition & spectral unmixing suite with spectral library matching and PCA-based anomaly detection |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Model | Imspector V10 / V10H / V10E / N17E / N25E / M50M |
| Spectral Range | 400–1000 nm (VNIR), 900–1700 nm (NIR), 1000–2500 nm (SWIR), 3.0–5.0 µm (MWIR) |
| Spectral Resolution | 2.8–35 nm (model-dependent) |
| Spatial Resolution | <40 µm to <9 µm (rms, model-dependent) |
| Slit Width Options | 18–150 µm (selectable) |
| Slit Length | 9.8–19 mm |
| Optical Interface | Standard C-mount or custom M43/M23 (MWIR) |
| F-number | f/2.0 (NIR/SWIR/MWIR models) |
| Stray Light | <0.5% |
| Throughput Efficiency | >50% (VNIR/NIR/SWIR), >65% (MWIR) |
| Housing Material | Anodized Aluminum |
| Operating Mode | Push-broom scanning with external CCD/InGaAs/MCT camera |
| Environmental Rating | Sealed optical path for dust resistance |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | Dualix Spectral Imaging |
|---|---|
| Model | Iris-V / Iris-SN / Iris-N |
| Type | Filter-Based Hyperspectral Imaging Module |
| Spectral Range | 400–720 nm (Iris-V), 550–1000 nm (Iris-SN), 900–1700 nm (Iris-N) |
| FWHM Bandwidth | 8–20 nm (customizable), e.g., 8 nm @ 550 nm (Iris-V/Iris-SN), 20 nm @ 900 nm (Iris-N) |
| Tuning Resolution | ≥1 nm |
| Aperture | 28 mm (standard), customizable up to 48 mm |
| Acceptance Angle | ±8° (Iris-V/Iris-SN), ±10° (Iris-N) |
| Switching Time | 50–150 ms |
| Wavelength Accuracy | FWHM/8 ± 0.5 nm |
| Operating Temperature | −10 to +40 °C |
| Storage Temperature | −20 to +80 °C |
| Power Supply | DC 5 V @ 8 A |
| Polarization Sensitivity | Transmission doubles under linearly polarized illumination vs. unpolarized (reference condition) |
| Brand | Dualix Spectral Imaging |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MICROXCAM |
| Imaging Modality | 3D Hyperspectral Imaging |
| Platform Compatibility | Ground-based & Airborne Deployment |
| Spectral Range | 500–1450 cm⁻¹ (7–20 µm) |
| Detector Technology | Uncooled Microbolometer Array with Gold-Black Broadband Absorber |
| Spectral Resolution | <16 cm⁻¹ (typical, configurable via integrated MEMS Fabry–Pérot tunable filter) |
| Spatial Resolution | ≤ 1.5 mrad IFOV (dependent on lens focal length and working distance) |
| Field of View (TFOV) | 12° × 9° (standard lens) |
| Frame Rate | Up to 25 Hz full-frame spectral cube acquisition |
| Data Output Format | Standard ENVI-compatible .hdr/.dat, IEEE 754 float32 |