Erlab
Filter
Showing 1–30 of 50 results
| Brand | Erlab |
|---|---|
| Model | Shelf 812A |
| Origin | Jiangsu, China |
| Dimensions (W×D×H) | 650 mm × 551 mm × 760 mm |
| Capacity | 16 × 0.5 L bottles/flasks |
| Filtration Standard | Compliant with AFNOR NFX 15-211 |
| Fan Type | Low-noise axial fan |
| Installation Options | Benchtop, wall-mounted, or floor-standing with optional support frame |
| Cabinet Door | Full-height transparent tempered glass |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | 531 |
| Compliance | NFX 15-211 (France), JG/T 385–2012 (China), SEFA 9 (USA), BS 7989 (UK) |
| Filtration Efficiency | <1% of OEL (Occupational Exposure Limit) / PC-TWA |
| Adjustable Shelf Height | Two Configurations — 10 cm clearance (e.g., 72 × 20 mL vials) or 20 cm clearance (e.g., 10 × 500 mL bottles) |
| Installation Type | Benchtop, modular mounting (above/below reagent shelving) |
| Power Supply | Standard 100–240 V AC, 50/60 Hz |
| Airflow | Continuous recirculating airflow with dual-stage molecular filtration |
| Filter Technology | Hybrid adsorption (physical + chemisorption) using activated carbon and impregnated media |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | 834 |
| Construction | Polypropylene (PP) cabinet body with modular molecular filtration system |
| Filtration Architecture | Multi-stage, customizable filter modules (acid, base, solvent, aldehyde, amine-specific media) |
| Safety Redundancy | Integrated safety pre-filter for fail-safe operation upon primary filter saturation |
| Control System | Microprocessor-based panel with fan status monitoring, real-time airflow verification, and optional filter saturation alert (Molecode S sensor module) |
| Compliance | Conforms to French Standard NFX 15-211 for ductless fume containment cabinets |
| Certification | Validated per SGS and Intertek (formerly ITS) test reports |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Biocap 321 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (Class 100) |
| Airflow Velocity | ≥0.3 m/s |
| Airflow Volume | 230 m³/h |
| Filter Class | H14 HEPA (EN 1822-1:2022, ≥99.995% @ 0.1 µm) |
| UV Lamp | Timer-Controlled, 254 nm |
| External Dimensions (W×D×H) | 800 × 657 × 890 mm |
| Internal Dimensions (W×D×H) | 767 × 530 × 600 mm |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Total Power Consumption | 58 W |
| Sound Pressure Level | 52 dB(A) |
| Fan Quantity | 1 |
| Compliance | EN 14644-1, EN 1822-1, IEC 61000-6-3, IEC 61000-6-4 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Biocap 391 |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (Class 100) Equivalent |
| Airflow Velocity | ≥0.3 m/s |
| HEPA Filter Grade | H14 (99.999% @ 0.3 µm) |
| Air Volume | 230 m³/h |
| Dimensions (W×D×H) | External 1010 × 677 × 950 mm, Internal 969 × 523 × 640 mm |
| Operating Voltage/Frequency | 100–240 V / 50–60 Hz |
| Power Consumption | 58 W |
| Sound Pressure Level | 52 dB(A) |
| Cabinet Pressure | Positive Pressure Relative to Ambient |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Biocap 712 |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (Class 100) |
| Air Velocity | > 0.3 m/s |
| Filtration | H14 HEPA Filter (EN 1822-1:2019) |
| Airflow Volume | 460 m³/h |
| Dimensions (W×D×H) | External 1750 × 689 × 950 mm |
| UV Lamp | Timer-Controlled, 254 nm |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Total Power Consumption | 105 W |
| Sound Pressure Level | 55 dB(A) |
| Fan Quantity | 2 |
| Compliance | EN 12464-1, ISO 14644-1, IEC 61000-6-3 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Captair 1634 Smart |
| Dimensions (L×W×H) | 1802 × 530 × 2172–2358 mm |
| Airflow Capacity | 220 m³/h |
| Input Voltage/Frequency | 100–240 V AC, 50–60 Hz |
| Internal Circuit | 24 V DC |
| Cabinet Material | Chemically resistant transparent polypropylene panels + acid-resistant polymer-coated galvanized steel |
| Filter Frame Material | Polypropylene (PP) |
| Filtration Technology | Patented modular dual-layer filter system (primary + safety filter) |
| Filter Types | GF4 BE+ (organic & inorganic vapors), GF4 AS (organic vapors only), GF4 F (formaldehyde), GF4 K (ammonia), GF4 HP (HEPA H14/U17 particulates per EN 1822:1998) |
| Compliance | JG/T 385–2012 (China), ANSI Z9.5–2012 (USA), AFNOR NF X 15-211:2009 (France), SEFA 9 (USA), BS 7989 (UK), DIN 12927 (Germany), CE marked |
| Safety Certification Reports | TÜV SÜD (formerly Intertek) test report per NF X 15-211, SGS report per SEFA 9, Tongji University report per JG/T 385–2012 |
| Face Velocity Monitoring | Integrated electronic anemometer |
| Filter Saturation Detection | Molecode® S (organics), Molecode® A (inorganics), Molecode® F (formaldehyde) |
| Exhaust Air Quality | Residual chemical concentration < 1% of OSHA/ACGIH TLV–TWA values |
| eGuard Remote Monitoring | Real-time status, configuration, audit log, push alerts via iOS/Android/web |
| Security | Dedicated access lock system |
| Storage Configurations | Open-front or 1–4 sliding doors |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Captair 822 Smart |
| Dimensions (L×D×H) | 820 × 350 × 730 mm |
| Airflow Capacity | 70 m³/h |
| Storage Capacity | >50 bottles (1 L each) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Internal Voltage | 24 V DC |
| Safety Lock | Integrated mechanical lock |
| Door Configuration | Dual transparent swing doors or optional sliding door |
| Filter Technology | Modular, multi-stage activated carbon + specialty impregnated media |
| Compliance | Designed per EN 14175-3 (fume cupboard performance), EN 61000-6-3 (EMC), EN 61000-6-1 (immunity), and aligned with ISO 15195 for laboratory air quality management |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Captair 834 Smart |
| Airflow Capacity | 220 m³/h |
| Dimensions (L×W×H) | 900 × 530 × 2138–2323 mm |
| Voltage/Frequency | 100–240 V AC / 50–60 Hz (Internal Circuit: 24 V DC) |
| Cabinet Material | Chemically resistant polypropylene (transparent front panels) + galvanized steel coated with acid-resistant polymer |
| Filter Frame Material | Polypropylene (PP) |
| Filtration Technology | Patented modular dual-layer filter system (primary + safety filter) |
| Safety Alarms | LED status band + audible tone coding for fan failure, face velocity deviation, or filter saturation |
| Compliance | AFNOR NF X 15-211:2009 (FR), SEFA 9 (US), BS 7989 (UK), DIN 12927 (DE), JG/T 385–2012 (CN), EN 1822:1998 (HEPA H14/ULPA U17) |
| Filter Efficiency | Residual chemical concentration < 1% of OSHA TWA or ACGIH TLV thresholds |
| Filter Saturation Detection | Molecode® S (organics), A (inorganics), F (formaldehyde) |
| Certified Test Reports | TÜV SGS (SEFA 9), Intertek (NF X 15-211), Tongji University (JG/T 385–2012) |
| Security | Dual-point mechanical lock |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M632 |
| Airflow Capacity | 460 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (per AFNOR NF X 15-211:2009) |
| Filter Configuration | Dual-layer molecular filtration system (Class 1 per NFX 15-211) |
| Power Consumption | 125 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 55 dB(A) |
| Dimensions (L × W × H, external) | 1600 × 620 × 1161–1345 mm |
| Operating Aperture | Elliptical |
| Lighting | 18 W fluorescent lamp(s), 500 lux, IP67 rated |
| Compliance | AFNOR NF X 15-211:2009, SGS-certified per NFX 15-211 filtration standard |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Captair Pyramid Portable Airtight Isolation Enclosure |
| Dimensions (L×W×H) | 860 mm × 560 mm × 725 mm |
| Application Type | Production-Scale Glove Box |
| Certification | Pre-shipment airtightness test at 2.5 mmHg gauge pressure |
| Construction | Reinforced polymer composite housing with integrated glove ports and HEPA/ULPA filtration interface |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Captair 321 |
| Cabinet Construction | Single-Face Recirculating Fume Hood |
| Cabinet Material | Polypropylene (PP) Panels with Acid-Resistant Polymer-Coated Galvanized Steel Frame |
| Airflow Volume | 220 m³/h |
| Face Velocity Range | 0.4–0.6 m/s |
| Safety Compliance | JG/T 385-2012, SEFA 9, CE, ISO 9001:2008 |
| Filter Options | GF4 AS (Organic), GF4 BE+ (Organic + Inorganic), GF4 F (Formaldehyde), GF4 K (Ammonia), GF4 HP (Particulates) |
| Smart Monitoring | eGuard Software Integration, Molecode Saturation Sensors (S/A/F), RGB Status Halo Indicator |
| Electrical Supply | 100–240 V AC / 50–60 Hz |
| Internal Circuit | 24 V DC |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M/S321W |
| Airflow Rate | 230 m³/h |
| Surface Air Velocity | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V |
| Sound Pressure Level | 52 dB(A) |
| Filter Configuration | Dual-layer molecular filter cartridge (Class 1 per NF X 15-211) |
| Dimensions (L×D×H, external) | 800 × 556 × 1016–1200 mm |
| Operating Aperture | Elliptical |
| IP Rating (Lighting) | IP67 |
| Illumination | 18 W fluorescent lamp, 500 lux |
| Compliance | NF X 15-211:2009, SGS-certified, TÜV-tested |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M391W |
| Construction | Fully Steel, Double-Sided Operation |
| Airflow Capacity | 230 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filtration System | Dual-layer molecular filter array (Class 1 per NF X 15-211) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC / 24 V DC internal |
| Sound Pressure Level | 52 dB(A) |
| Dimensions (L×W×H, mm) | External 1000 × 620 × 1161–1345 |
| Lighting | 18 W fluorescent lamp(s), 500 lux, IP67 rated |
| Certifications | Compliant with NF X 15-211:2009, SGS & Intertek validated performance report |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | S/M321 |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 230 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filtration System | Dual-Layer Molecular Filter Assembly (Class 1 per NFX 15-211) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 52 dB(A) |
| Lighting | 18 W IP67 Fluorescent Lamp(s), ≥500 lux |
| Dimensions (S model, mm) | L 800 × D 556 × H 1016–1200 (external) |
| Dimensions (M model, mm) | L 800 × D 620 × H 1161–1345 (external) |
| Operating Aperture | Elliptical |
| Certification | Compliant with NFX 15-211:2009 Class 1 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Shelf 812A / 812B / 812C |
| Type | Desktop / Floor-Standing / Wall-Mounted |
| Internal Dimensions (W×D×H) | 738 × 188 × 348 mm |
| External Dimensions (W×D×H) | 821 × 280 × 582 mm (812A), 821 × 310 × 792 mm (812B), 821 × 295 × 582 mm (812C) |
| Noise Level | 45 dBA |
| Airflow Rate | 75 m³/h |
| Air Exchange Rate | 25 cycles/min |
| Voltage/Frequency | 220 V / 50 Hz |
| Power Consumption | 20 W |
| Current Draw | 0.17 A |
| Filtration Standard | Compliant with AFNOR NFX 15-211 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M632W |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 460 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filter System | Dual-layer molecular filtration (Class 1 per NF X 15-211) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Rated Power Consumption | 125 W |
| Sound Pressure Level | 55 dB(A) |
| Internal Dimensions (L×W×H) | 1497 × 522 × 866 mm |
| External Dimensions (L×W×H) | 1600 × 620 × 1161–1345 mm |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, 500 lux |
| Control Interface | Integrated Captair® Flex™ digital control panel with airflow monitoring, timer-based filter saturation alert (60-hr interval), and optional Melecode™ S organic vapor alarm module |
| Filter Monitoring | Dedicated sampling port for colorimetric tube-based breakthrough detection |
| Ergonomics | Angled front panel, elliptical access opening, central splash guard, and curved work surface edge |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Chemtrap V 201 |
| Dimensions (L×W×H) | 200 × 537 × 605 mm |
| Sound Level | 55 dBA |
| Airflow Capacity | 75 m³/h |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 19 W |
| Current Draw | 0.1 A |
| Telescopic Duct Length | 1 m (Ø80 mm) |
| Flange Diameter Range | Ø75–110 mm |
| Filtration Standard | NFX 15-211 Class 2 (organic vapors) |
| Filter Lifetime | ~12 months (typical, dependent on VOC load and exposure profile) |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | e632 |
| Cabinet Construction | All-Steel |
| Ventilation Type | Ductless (Recirculating) |
| Air Intake Method | Compensated (Bypass) Design |
| Application Domain | Chemical Handling |
| Exhaust Position | Top Exhaust |
| Ducting Requirement | None (Self-Contained Filtration System) |
| Work Area Dimensions (W×D×H) | 1606 mm × 615 mm × 1107 mm |
| Overall Dimensions (W×D×H) | 1606 mm × 615 mm × 1107 mm |
| Average Face Velocity | 0.4–0.6 m/s |
| Airflow Volume | 440 m³/h |
| Lighting | Integrated LED Tubes |
| Rated Power | 125 W |
| Electrical Input | 100–240 V AC, 50–60 Hz |
| Internal DC Supply | 24 V |
| Filter Architecture | Modular Vertical Stack (FLEX Technology) Supporting Combined Activated Carbon + HEPA/ULPA Configurations |
| User Capacity | 1–2 Operators |
| Net Weight | 55.7 kg |
| Noise Level | Compliant with ISO 15714 and EN 14175-3 for Laboratory Ambient Acoustics |
| Water Connection | Not Required (No Utility Water Interface) |
| Compliance | Meets EN 14175-3 (2022), ASTM E1192-21, and OSHA 1910.1450 Requirements for Ductless Fume Control |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | Ecosystem |
| Pricing | Available Upon Request |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Flow 483 Smart |
| Pricing | Upon Request |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100) |
| Noise Level | 61 dB(A) |
| User Capacity | Single-user, front-access only |
| Airflow Pattern | Vertical downward laminar flow |
| Filter Options | HEPA H14 (≥99.995% @ 0.1 µm) or ULPA U17 (≥99.999995% @ 0.1 µm) |
| Compliance | EN ISO 14644-1:2015 |
| Brand | Erlab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Clean Air Enclosures 321 |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Cabinet Material | Fully Stainless Steel |
| Ventilation Type | Ductless (Recirculating) |
| Filtration | HEPA H14 (99.995% @ 0.3 µm) or ULPA U17 (99.999995% @ 0.12 µm) |
| Cleanroom Classification | ISO Class 5 (EN ISO 14644-1:2015) |
| Optional Add-on | Molecular Filter (Activated Carbon + Impregnated Media) for VOC Removal |
| Safety Monitoring | Real-time 360° airflow & filter integrity sensing via SmartLight™ optical interface |
| Compliance | EN 12464-1, EN 14175-5, IEC 61000-6-3, CE-marked |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | GFH3 6400 |
| Construction | All-Steel Enclosure |
| Type | Ductless (Recirculating) Fume Hood |
| Exhaust Mode | Top Exhaust |
| Airflow Design | Full-Flow Recirculation |
| Surface Average Face Velocity | 0.4–0.6 m/s |
| Total Airflow Capacity | 880 m³/h |
| Lighting | Integrated LED |
| Noise Level | Low-Noise Operation (Compliant with ISO 15714 & EN 14175-3) |
| User Capacity | 1–2 Operators |
| Work Area Dimensions (W×D×H) | 1849 × 968 × 1571/1661 mm |
| External Dimensions (W×D×H) | 1849 × 968 × 1571/1661 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | Meets EN 14175-3, ASTM E1192, and ISO 15714 for ductless fume hood performance and operator protection |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | Halo Sense |
| Monitoring Parameters | VOCs, Acid Gases, Formaldehyde |
| Environmental Operating Range | Temperature 10–30 °C, Relative Humidity 30–80 % RH |
| Power Consumption | 10 W |
| Electrical Supply | 100–240 V AC, 50–60 Hz |
| Sensor Technology | Semiconductor & Electrochemical Sensors (gas-specific) |
| Mounting Options | Benchtop or Wall-Mounted |
| Status Indication | Smart RGB Light Band |
| Data Acquisition | eGuard Software (PC & Mobile) |
| Compliance Context | Designed for GLP-aligned lab environments |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Sense |
| Detection Targets | VOCs, Acidic Gases, Formaldehyde |
| Sensor Types | Metal Oxide Semiconductor (VOC), Electrochemical (Acid & Formaldehyde) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Power Consumption | 10 W |
| Enclosure Material | Lightweight, Durable Plastic |
| Mounting Options | Wall-mounted or Desktop |
| Weight | 1 kg |
| Compliance | CE, RoHS, EN 61000-6-3, EN 61000-6-1 |
| Software Platform | eGuard Cloud-Enabled Monitoring Suite |
| Data Connectivity | Ethernet (RJ45), Wi-Fi (optional), USB for local configuration |
| Alarm Output | Visual (RGB Status Light Band), Audible (85 dB @ 30 cm), Push Notifications via eGuard App |
| Brand | Erlab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Halo Sense Smart |
| Price Range | USD 1,400 – 2,800 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Smart |
| Airflow Capacity | Up to 220 m³/h |
| Filtration Technology | Ionized Cascade (Ion-Enhanced Multi-Stage Adsorption) |
| Power Consumption | 50 W |
| Operating Voltage/Frequency | 100–240 V / 50–60 Hz |
| Weight (incl. filters) | 31 kg |
| Installation | Ceiling-suspended via 4 lifting lugs or wall-mounted using 4 brackets |
| Connectivity | 1 × Ethernet port for e-Guard remote monitoring |
| Sensor Suite | Semiconductor sensor (VOCs), electrochemical sensors (acids, formaldehyde) |
| Control Interface | Visual status indicator (LED beam pulsing), mobile app integration via Erlab Smart platform |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Halo Smart P |
| Pricing | Available Upon Request |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Instrument Enclosure 001 |
| Pricing | Available Upon Request |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M321F |
| Airflow Type | Vertical Laminar Flow |
| Filtration Class | ISO Class 5 (equivalent to US Federal Standard 209E Class 100) |
| Filter Efficiency | ≥99.995% @ 0.3 µm (EN 1822-1, MPPS method) |
| HEPA Filter Grade | H14 |
| Face Velocity | >0.3 m/s |
| Airflow Volume | 230 m³/h |
| Sound Pressure Level | 52 dB(A) |
| Power Supply | 100–240 V, 50–60 Hz |
| Total Power Consumption | 58 W |
| Dimensions (W×D×H, mm) | External 800 × 620 × 1161–1246 |
| Internal Work Area (W×D×H, mm) | 764 × 546 × 866 |
| Pre-filter Monitoring | Integrated differential pressure gauge |
| Alarm System | Audible and visual fan failure alert |
| Standard Work Surface Options | 2 mm brushed 304 stainless steel or 25 mm solid phenolic resin with chemical-resistant finish and integral spill containment trough |
| Optional Add-ons | Fixed-height ergonomic workbench with leveling feet |