EURO TECH
Filter
Showing all 12 results
| Brand | EURO TECH |
|---|---|
| Model | ET1301 |
| Measurement Range | 0–100 µg/L (Chlorophyll a) |
| Detection Principle | Pulse-Amplitude Modulated (PAM) Fluorescence |
| Linearity | R² = 0.998 |
| Weight | 0.65 kg |
| Dimensions | 190 × 105 × 60 mm |
| Operating Temperature | 5–40 °C |
| Power Supply | 4 × AA batteries (5 V DC nominal) |
| Data Storage Capacity | 500 measurement sets |
| Environmental Rating | IPX4 (splash-resistant) |
| Sample Cell | 1 × 1 mm quartz cuvette (non-matched, low-sensitivity-to-cell-variability design) |
| Input Parameters | pH, temperature, turbidity (manual entry) |
| Output Interface | ASCII via USB |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Model | ET1020A |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0.5 ppm – 10,000 ppm |
| Accuracy | ±3% for TC/TIC/TOC |
| Resolution | 1 ppb |
| Detection Efficiency | ≥95% at 10 ppm |
| Repeatability | 3% RSD |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET1151M |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Rapid Digestion Spectrophotometry |
| Wavelengths | 420 nm, 610 nm |
| COD Range | 0–1000 mg/L |
| TN Range | 0–150 mg/L |
| TP Range | 0.02–20 mg/L |
| Accuracy | ≤ ±5% |
| Repeatability | RSD ≤ 3% |
| Detection Limit | 0.1 mg/L (COD), 0.01 mg/L (TP), 0.1 mg/L (TN) |
| Measurement Time | 20 min per sample |
| Throughput | 1 sample per run |
| Optical Source | High-Stability LED |
| Wavelength Accuracy | ±3 nm |
| Photometric Modes | Absorbance, Transmittance (%T), Concentration |
| Stability | ΔA < 0.005 over 20 min |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET1202 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Spectrophotometry (Dual-Wavelength Absorption at 3030 cm⁻¹, 2960 cm⁻¹, and 2930 cm⁻¹) |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 0.2 mg/L (CCl₄ extract), 0.4 mg/L (C₂Cl₄ extract) |
| Wavenumber Accuracy | ±2 cm⁻¹ |
| Wavenumber Reproducibility | ±1 cm⁻¹ |
| Spectral Scan Range | 3400–2400 cm⁻¹ |
| Resolution | 0.1 ppm (as oil equivalent) |
| Measurement Frequency | 2 measurements/minute |
| Baseline Drift | <0.005 AU/30 min |
| Linearity Coefficient | ≥0.999 |
| Repeatability | RSD ≤1% (at 40 mg/L oil standard) |
| Sample Measurement Time | 35 seconds |
| Output Interface | USB 2.0 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 50 × 38 × 22 cm |
| Weight | 15 kg |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET1302 |
| Measurement Principle | Pulsed Amplitude Modulated (PAM) Chlorophyll-a Fluorescence |
| Detection Target | Phytoplankton in 10–50 µm and <10 µm size fractions |
| Sample Volume | 4 mL |
| Response Time | ≤60 s per measurement |
| Optical Path | 10 mm × 10 mm quad-cell cuvette |
| Instrument Weight | 0.68 kg |
| Dimensions | 200 mm × 105 mm × 35 mm |
| Enclosure Material | Polycarbonate (IPX4 splash-resistant) |
| Operating Temperature | 5–40 °C |
| Power Supply | 4 × AA alkaline batteries |
| Data Storage | 500 measurement records |
| Connectivity | Bluetooth 4.2 |
| Compliance Reference | IMO Ballast Water Management Convention (BWMC) Regulation D-2, MEPC.127(53), MEPC.252(67) |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | ET1500 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (lyophilized bioluminescent bacteria) |
| Operating Temperature Range | 15–40 °C |
| Reagent Storage Temperature | 2–8 °C (reconstituted), –20 °C (lyophilized long-term) |
| Coefficient of Variation (CV) | ≤1% (intra-assay, n=10 at IC₅₀ concentration) |
| Batch Capacity | 4 assay groups × 17 samples per group |
| Exposure Time | 0–99 s (programmable in 1-s increments) |
| Detection System | Photomultiplier Tube (PMT) |
| Spectral Response | 300–650 nm (peak sensitivity at 400 nm) |
| Light Measurement Range | 0–1,000,000 RLU (Relative Light Units) |
| Sample Vessel | 12 mm diameter × 55 mm height glass or polystyrene test tube |
| Data Storage | 1900 measurement records with timestamp, sample ID, and exposure time |
| Interface | RS-232C serial port for PC connectivity and data export |
| Display | Backlit LCD (128 × 64 pixels) |
| Power Supply | 4 × AA alkaline or Ni-MH rechargeable batteries (≥2600 mAh capacity) or external AC adapter (220 V ±10%, 50 Hz) |
| Dimensions (L×W×H) | 320 × 170 × 180 mm |
| Weight | 2.0 kg |
| Environmental Operating Conditions | 10–90% RH (non-condensing) |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200B |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 500 mL × 3 |
| Extraction Cycle Time | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Positions | 3 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 30 W |
| Net Weight | 15.7 kg |
| Operating Principle | Mechanical Stirring-Assisted Phase Separation |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200C |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 1000 mL × 3 |
| Extraction Time Range | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Throughput | 3 independent stations |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 20 W |
| Net Weight | 15.7 kg |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3301A |
| Instrument Type | Purge-and-Trap Nitrogen Evaporator |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity | 60 samples |
| Gas Inlet Pressure | 60–100 psi |
| Maximum Gas Flow per Nozzle | 2 L/min |
| Timer Range | 1–999 min |
| Power Supply | 230 V, 50 Hz (optional 110 V, 60 Hz) |
| Dimensions (W×H×D) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Shipping Weight | 35 kg |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3302A |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 95 °C (adjustable) |
| Temperature Stability | ±2–4 °C |
| Sample Capacity | 6 positions (compatible with 50 mL and 200 mL glass tubes) |
| Gas Flow Control | 4–25 PSI (adjustable) |
| Heating Power | 1100 W |
| Endpoint Detection | Optical sensor-based auto-termination |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3302B |
| Sample Capacity | 6 × 50 mL or 6 × 200 mL |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±1 °C |
| Gas Flow Control Range | 4–25 psi |
| Endpoint Detection Options | 0.5 mL or 1.0 mL (optical sensor) |
| Operating Modes | Auto-Endpoint, Manual, Timer, Auto-Endpoint + Timer |
| Water Bath Temp Range | Ambient to 60 °C |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×D×H) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Exhaust Port | 5 cm ID × 3 m exhaust hose included |
| Gas Inlet | 8 mm OD tubing |
| Recommended Gas Supply Pressure | ≥40 psi (regulated), max 100 psi |
| Typical Evaporation Rate | 2–8 mL/min (dependent on bath temp & gas flow) |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3303 |
| Sample Capacity | 12 positions (compatible with 50 mL and 200 mL glass tubes) |
| Temperature Range | Ambient to 60 °C |
| Gas Pressure Range | 0–25 psi (adjustable) |
| Endpoint Detection Options | 0.5 mL or 1.0 mL (optical sensor-based) |
| Display | 8-inch capacitive touchscreen |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×H×D) | 54 cm × 31 cm × 35 cm |
| Net Weight | 25 kg |
| Exhaust Duct | 5.1 cm ID × 3.0 m length included |
| Timer Range | 1–999 minutes |
| Gas Inlet Requirement | Minimum 40 psi supply pressure, regulated to ≤100 psi maximum |
