Formulaction (Microtrac)
Filter
Showing all 6 results
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | FLUIDICAM |
| Viscosity Range | 0.1–200,000 cP |
| Shear Rate Range | 100–1.8×10⁵ s⁻¹ |
| Temperature Control Range | 4–80 °C |
| Compliance | Designed for GLP/GMP-relevant workflows with audit-trail-capable software logging |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | Rheolaser Master |
| Instrument Type | Optical Microrheometer |
| Sample State | Liquid |
| Measurement Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Temperature Range | +5°C above ambient to 90°C (optional up to 150°C) |
| Frequency Range | 10⁻⁴ Hz to 10² Hz |
| RMS Particle Displacement Range | 0.1 nm – 100 nm |
| Minimum Detectable Particle Size | 50 nm |
| Maximum Solid Volume Concentration | 90% v/v |
| Torque Specifications | Not applicable (non-mechanical, optical measurement) |
| Data Acquisition | High-resolution CMOS camera-based speckle image analysis |
| Sample Holder | 20 mL borosilicate glass cuvette with 6-position sample carousel |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN AGS |
| Light Source | 880 nm pulsed near-infrared LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Maximum Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5°C to 60°C |
| Temperature Accuracy | ±0.5°C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Scan Interval | As low as 20 s per scan |
| Programmable Scan Sequences | Up to 250 |
| Sample Capacity | 54 positions |
| Dimensions (W×D×H) | 145 × 75 × 85 cm |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Light Source | 880 nm pulsed near-infrared LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.01–1000 µm |
| Maximum Volume Concentration | up to 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Temperature Accuracy | ±0.5 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Modes | Full-height scanning (every 20 µm) or fixed-position kinetic monitoring |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TMIX |
| Light Source | 880 nm NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Interval | 20 s |
| Compliance | Designed for GLP-compliant stability assessment |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Light Source | 880 nm pulsed NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.01–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | 4–80 °C |
| Temp. Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Scan Frequency | 1 scan per 20 s (at ambient) |
| Temp. Regulation Interval | Every 30 s |
| Max. Programmable Scan Steps | 250 |
| Sample Capacity | 6 positions |
| Dimensions (W×D×H) | 35 × 45 × 90 cm |