| Brand | FORZA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FT-D892-A-C/H |
| Compliance | ASTM D892, ASTM D6082, GB/T 12579, SH/T 0722 |
| Temperature Range | Ambient +5 °C to 160 °C (stability ±0.5 °C) |
| Air Flow Control | 94 ±5 mL/min (ASTM D892) or 200 ±5 mL/min (ASTM D6082), accuracy ±1% of full scale |
| Heating/Cooling Method | Forced-air bath |
| User Interface | Touchscreen with real-time parameter display and control |
| Safety | Over-temperature protection |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | ITH Oxi Plus |
| Temperature Range | 40–250 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Flow Measurement Options | Rotameter or Digital Mass Flow Controller |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | RU-D665-L-4/6 |
| Test Positions | 4 or 6 independent stations |
| Stirrer Speed | 1000 rpm |
| Temperature Range | +40 °C to +80 °C |
| Temperature Stability | ±0.5 °C |
| Bath Material | Stainless Steel with Drain Port |
| Compliance | ASTM D665, NACE TM01-72, GB/T 11143 |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | LTRV-D2983-L-10 |
| Standards Compliance | ASTM D2983, ISO 9262, IP 267, GB/T 11145 |
| Temperature Range | +20 °C to –55 °C |
| Bath Type | Liquid-immersion thermal bath with nitrogen purge |
| Sample Capacity | 10 samples per bath |
| Control Interface | Integrated touchscreen controller with real-time bath temperature display |
| Cooling Profile | Programmable air-bath emulation mode |
| Viewing | Full panoramic optical access to samples in bath |
| Mounting | Direct floor-standing installation—no wooden pallet or external support required |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | HFLT-AFNOR-M-2 |
| Standards Compliance | IP 448, ISO 13357, AFNOR NF E 48-690 & NF E 48-69, SH/T 0805-2008 |
| Test Vessel Material | Stainless Steel |
| Vessel Volume | 350 mL |
| Pressure Control Accuracy | ±5 kPa |
| Independent Test Stations | 1, 2 or 4 (user-configurable) |
| Integrated Air Supply | Equipped with coalescing and desiccant filtration |
| Data Processing | Includes dedicated Windows-based calculation utility for automatic filtration performance reporting |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | Oxi Plus |
| Temperature Range | 40–150 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity | 4–30 test tubes (method-dependent) |
| Safety Features | Over-temperature cutoff switch, low-level liquid protection switch |
| Flow Monitoring | Glass rotameter included |
| Import Status | Imported |