FOSS
Filter
Showing 1–30 of 38 results
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BactoScan FC |
| Measurement Principle | Flow Cytometry |
| Detection Target | Total Viable Bacteria in Raw and Processed Milk |
| Detection Range (L-mode) | 2.0 × 10⁵ – 2.0 × 10⁷ IBC/mL (≈ 8.0 × 10⁴ – 1.0 × 10⁷ CFU/mL) |
| Detection Range (H-mode) | 5.0 × 10³ – 2.0 × 10⁷ IBC/mL (≈ 1.5 × 10³ – 1.0 × 10⁷ CFU/mL) |
| Throughput | 50–150 samples/hour |
| Sample Temperature Range | 2–42 °C |
| Warm-up Time | <15 min |
| Shutdown Time | <5 min |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Alphatec™ FNO |
| Application | Falling Number determination per ISO 3093, AACC 56-81B, ICC 107/1, and ASTM D7827 |
| Sample Types | Wheat, Rye, Barley, Sorghum, Flour, and other cereal-based materials |
| Measurement Principle | Viscosity-based enzymatic hydrolysis of starch gel under standardized boiling conditions |
| Display | 7-inch capacitive touchscreen interface with multilingual OS support |
| Compliance | Fully aligned with GLP/GMP data integrity requirements |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BacSomatic |
| Automation | Fully Automatic |
| Analysis Speed | 40 samples/hour |
| Detection Range | SCC: 100,000–1,500,000 cells/mL |
| IBC | 5,000,000–20,000,000 IBC/mL |
| Repeatability | SCC: CV < 3% at 500,000 cells/mL |
| Accuracy | SCC: Typical Sy,x < 0.25 log units vs. Standard Plate Count (SPC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Fat Detection Range | 0–15% |
| Repeatability (CV) | <0.5% |
| Fat Precision (CV) | <1.0% |
| Sample Types | Bovine, Ovine, Caprine, and Buffalo Milk |
| Key Parameters | Fat, True Protein, Crude Protein, Casein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Free Fatty Acids, Fatty Acid Profile, Freezing Point, pH, Ketosis Screening (BHB & Acetone), Adulteration Detection, Somatic Cell Count (SCC), Differential Somatic Cell Count (DSCC) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CombiFoss 7 |
| Automation Level | Fully Automatic |
| Analysis Throughput | 600 samples/hour |
| Somatic Cell Count (SCC) Range | 0–10 × 10⁶ cells/mL |
| Repeatability | < 2% CV |
| Accuracy | ±0.1–1.5 × 10⁶ cells/mL |
| Sample Temperature Range | 30–42 °C |
| Regulatory Compliance | Designed for ISO 8570, IDF 141, AOAC 991.19, and EU Regulation (EC) No 853/2004 compliance |
| Detection Capabilities | Fat, Protein, True Protein, Lactose, Total Solids, Non-Fat Solids, Urea, Citric Acid, Freezing Point, Casein, Free Fatty Acids, pH, Monounsaturated Fatty Acids (MUFA), Polyunsaturated Fatty Acids (PUFA), Total Unsaturated Fatty Acids, Total Saturated Fatty Acids, Sample Inlet Temperature, Somatic Cell Count (with FM FC module) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | CT 293 |
| Instrument Type | Cyclonic Grinder |
| Sample Applicability | Hard, brittle, and fibrous materials (e.g., cereals, seeds, feed, leaves, tablets, tobacco, limestone, coal) |
| Feed Size | ≤10 mm (standard inlet), up to 40 mm (optional large inlet) |
| Output Particle Size | 0.01–0.5 mm |
| Particle Distribution | ≥95% retained on 1 mm sieve |
| Rotational Speed | 10,000 rpm |
| Grinding Rate | ~4 g/s |
| Noise Level | <75 dB(A) |
| Compliance | AOAC Official Method 995.13 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | DairyScan |
| Automation | Fully Automatic |
| Analysis Time | 45 seconds per sample (15 sub-samples per run) |
| Measurement Range | Fat 0–36% w/w |
| Repeatability | ≤0.25% CV |
| Accuracy | ≤1.0% CV |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Sample Throughput | Up to 80 samples/hour (typical operational rate) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Digestor™ 2508 and Digestor™ 2520 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Temperature Range | Ambient to 440 °C |
| Temperature Stability | ±1 °C at 400 °C |
| Temperature Accuracy | ±1 °C across full range |
| Max. Tube Capacity | 8 (Digestor™ 2508) / 20 (Digestor™ 2520) tubes per batch |
| Tube Volumes Supported | 100 mL, 250 mL, 400 mL |
| Heating Time (20 °C → 400 °C) | ~35 min (2508), ~40 min (2520) |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 1100 W (2508), 2300 W (2520) |
| Dimensions (W×D×H) | 300×440×140 mm (2508), 300×600×140 mm (2520) |
| Net Weight | 10 kg (2508), 18 kg (2520) |
| Exhaust Flow Rate | 3–5 L/min (initial 5 min), then 1 L/min (2508) |
| Application Memory | Up to 254 methods (127 FOSS-standard + 127 user-defined) |
| Max. Steps per Method | 23 (including ramp, hold, cool-down, wash cycles) |
| Communication Interface | Bidirectional PC interface compliant with GLP traceability requirements |
| Optional Accessories | Integrated fume extraction duct, external scrubber unit, programmable peristaltic wash system |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec 8000 |
| Principle | Gravimetric Crude Fiber and Detergent Fiber Analysis (Weende & van Soest Methods) |
| Sample Throughput | Up to 6 samples per run |
| Digestion Vessels | Ceramic crucibles (standardized, pre-weighed) |
| Reagent Handling | Fully automated acid/alkali/enzyme dosing and temperature-controlled digestion |
| Compliance | AOAC 978.10, AOAC 985.29, AACC 32-05, ISO 6865, EN ISO 13906 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fibertec™ 1023 |
| Application Principle | Enzymatic-gravimetric method per AOAC 991.43, AOAC 2009.01, AACC 32–07, NMKL 158, and ASP methods |
| Sample Capacity | 12 samples per digestion batch, 6 samples per filtration batch |
| Digestion Vessel Volume | 600 mL |
| Water Bath Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.1 °C |
| Oscillation Speed | 0–150 cycles/min |
| Oscillation Amplitude | 0–50 mm |
| Filtration Throughput | 2–4 min per 100 mL digested slurry |
| Reproducibility | RSD < 0.5% for total dietary fiber (TDF) across replicate analyses |
| Compliance | Fully aligned with AOAC Official Methods of Analysis®, ISO 13905:2014, and USP <2040> for dietary fiber quantification |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | FoodScan 2 |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 400–1100 nm |
| Sample Throughput | 15–25 seconds per sample |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission and Reflectance |
| Chemometric Software Engine | Artificial Neural Network (ANN) Calibration |
| Regulatory Certification | AOAC Official Method of Analysis™ 983.18 |
| Application Scope | Raw and processed meat, poultry, and aquatic products (porcine, bovine, avian, etc.) |
| Key Analytes | Fat, Protein, Moisture, Collagen, Salt (Cl⁻ basis), Lean Meat Content |
| Optional Extensions | Saturated Fatty Acids, Ash, Sodium-based Salt, Water Activity, Color Parameters |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Fossomatic 7 |
| Automation Level | Fully Automatic |
| Analysis Speed | Up to 600 samples/hour |
| Detection Range | 0–10 × 10⁶ cells/mL |
| Repeatability | CV < 4% at 500,000 cells/mL |
| Accuracy | < 10% deviation vs. direct microscopic count |
| Technology | Flow Cytometry |
| Compliance | ISO 13366-1, IDF 148, FDA/NCIMS Grade A Standards |
| Software Platform | Foss Integrator NOVA |
| Sample Types | Bovine, ovine, caprine, and buffalo milk |
| Configuration Options | Fossomatic 7 (total SCC) and Fossomatic 7 DC (somatic cell differential counting) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Grain & Flour |
| Instrument Type | Laboratory Near-Infrared Spectrometer |
| Principle | Grating-based Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 60 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | ANN (Artificial Neural Networks), PLS (Partial Least Squares) |
| Path Length Control | Motorized, 6–33 mm auto-adjustable |
| Subsample Capacity | 1–30 (standard: 10) |
| Analysis Time | 60 s (10 subsamples, including bulk density) |
| Compliance | EN 15948, IP54 dust- and splash-resistant enclosure |
| Patents | US 4,944,589 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Nova |
| Instrument Type | Benchtop |
| Analysis Time | 40 s |
| Sample Mass | 5 g |
| Scan Speed | 10 s |
| Wavelength Range | 1100 nm |
| Sample Form | Whole grain or milled flour, no preparation required |
| Calibration Basis | Artificial Neural Network (ANN) with >50,000 reference samples |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec™ Sofia |
| Instrument Type | Portable Near-Infrared Spectrometer |
| Wavelength Range | 850–1050 nm |
| Measurement Mode | Transmission NIR |
| Analysis Time | ~3 minutes for 10 subsamples |
| Dimensions (W × D × H) | 255 × 390 × 295 mm |
| Weight | 9 kg |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | <93% RH (non-condensing), up to 100% cyclic |
| Power Supply | 100–240 V AC, 50–60 Hz, Class I with earth grounding |
| EMC Environment | Light industrial, agricultural & mobile machinery |
| Sample Preparation | None required (whole-grain analysis) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 – 210 mg N |
| Distillation Flow Rate | ~40 mL/min |
| Repeatability | ≤1% RSD |
| Recovery Rate | >99.5% (for 1–200 mg N) |
| Power Consumption | 3000 W |
| Dimensions (L×W×H) | 500 mm × 480 mm × 760 mm |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Kjeltec™ 9 Distillator |
| Instrument Type | Kjeldahl Nitrogen Distillation Unit |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–210 mg N |
| Distillation Time | 3.5 min |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | Solids: 0.2–2 g |
| Semi-solids | 2–5 g |
| Liquids | 10–25 g |
| Nitrogen Recovery Rate | >99.5% |
| Power Rating | 3000 W |
| Dimensions (L×W×H) | 500×480×790 mm |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FOSS Kjeltec™ 9 Kjeldahl Nitrogen Analyzer |
| Pricing | Available Upon Request |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | KN295 |
| Instrument Type | Knife Mill |
| Sample Applicability | Hard, High-Fat, High-Moisture & High-Fiber Materials |
| Feed Size | <15 mm |
| Output Particle Size | 3–4 mm (pre-grinding) |
| Batch Capacity | 100 mL (50–150 g) |
| Rotational Speed | 20,000 rpm |
| Cooling | Integrated Tap-Water or Lab-Cooled Water Circulation System |
| Safety | Interlocked Lid Switch (halts rotation within 1 s) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatMaster II |
| Technology | X-ray Transmission |
| Sample Types | Raw, chilled, or frozen meat (bone-in or boneless |
| Detection Parameters | Fat content, mass, foreign object detection (metal, bone) |
| Compliance | Designed for food processing environments meeting EU Hygiene Regulation (EC) No. 852/2004, HACCP principles, and compatible with GMP/GLP-aligned QA workflows |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatScan |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based non-scanning array detector |
| Wavelength Range | 850–1050 nm |
| Scan Time | 45 seconds per sample (including 15 subsamples) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Artificial Neural Network (ANN)-based calibration |
| Sample Form | Homogenized meat mince (pork, poultry, beef, lamb) |
| Output Parameters | Fat content (%), Moisture content (%) |
| Weight | 12 kg |
| Compliance | Designed for GLP-compliant environments |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Instrument Type | Benchtop |
| Design | Modular |
| Sample Throughput | 60 samples per auto-sampler tray |
| Core Technology | Laser-Induced Breakdown Spectroscopy (LIBS) |
| Target Elements | Ca, Mg, P, K, Na, S (macronutrients) |
| Sample Forms | Fresh grass, silage (maize, barley, sorghum), alfalfa/legumes, hay, semi-dry forage, straw, clover, mixed hay |
| Reagent-Free Operation | Yes |
| Compliance Context | Designed for agricultural QA/QC workflows aligned with ISO 17025–accredited laboratory practices and feed industry GLP requirements |
| Brand | FOSS |
|---|---|
| Country of Origin | Denmark |
| Model | MilkoScan FT3 |
| Detection Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids, Freezing Point, Titration Acidity, Density, Free Fatty Acids, Citric Acid, Casein, Urea, Sucrose, Glucose, Fructose, Galactose |
| Automation Level | Fully Automatic |
| Analysis Time | 30 seconds per sample |
| Precision (CV) | < 0.25% (Fat, Protein, Lactose), < 0.20% (Total Solids), < 1 m°C (Freezing Point) |
| Sample Volume | < 8.0 mL |
| Flow System | Fully Automated Cleaning & Zeroing with Adaptive Adjustment |
| Connectivity | LIMS, FossManager™ Software |
| Dimensions | 750 × 450 × 408 mm |
| Weight | 43 kg |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Milkoscan Mars |
| Automation | Fully Automatic |
| Analysis Time | 1 min per sample |
| Measurement Parameters | Fat, Protein, Lactose, Total Solids, Non-Fat Solids |
| Repeatability | ≤0.5% CV (for raw milk major components) |
| Accuracy | ≤1.2% CV (for raw milk major components) |
| Technology | Fourier Transform Infrared (FTIR) Spectroscopy |
| Compliance | Designed for ISO 9001–certified dairy QA/QC environments |
| Screening Capability | Pre-installed ASM (Adulterant Screening Module) models for urea, sucrose, formaldehyde, sodium bicarbonate, potassium nitrate, and other common adulterants |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MilkoScan™ FT2 |
| Automation | Fully Automatic |
| Analysis Time | 30 s |
| Sample Volume Range | 4–25 mL |
| Repeatability | <0.2% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Accuracy | <0.8% CV (for fat, protein, lactose, total solids, SNF in raw milk) |
| Operating Temperature Range | 5–55 °C |
| Carry-over | <1% |
| Optical System | Sealed, temperature-controlled FTIR interferometer |
| Calibration Methods | Intercept/slope adjustment |
| Supported Chemometric Models | PLS, modified PLS, PCA |
| Compliance | CE-marked |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MycoFoss |
| Detection Principle | Bead-based Flow Cytometric Immunoassay |
| Sample Throughput | Up to 12 samples per run |
| Assay Time | ≤8 minutes per sample |
| Target Analytes | Aflatoxins (AFB1, AFB2, AFG1, AFG2), Deoxynivalenol (DON), Zearalenone (ZEA), Ochratoxin A (OTA), T-2 Toxin, Fumonisins (FB1, FB2, FB3) |
| Sample Types | Ground corn, wheat, and barley |
| Automation Level | Fully automated sample preparation, assay execution, and data reporting |
| Compliance Support | Audit-trail enabled, 21 CFR Part 11–ready software architecture, GLP/GMP-aligned workflow design |
| Data Management | Integrated instrument control, result traceability, PDF report generation, and CSV export |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DA1650 |
| Instrument Type | Laboratory Benchtop |
| Optical Principle | Grating-based Diode Array Scanning |
| Wavelength Range | 1100–1650 nm |
| Scan Time | 1 minute per spectrum |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance, Transmission (for liquids) |
| Chemometrics Software | WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 F |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating Scanning |
| Wavelength Range | 850–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Interface | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Pre-Standardized, Inter-Instrument Transferable Calibration |
| Language Options | English or Chinese UI & Network Management Software |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capabilities in WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Identification | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Inter-instrument Transferable Standardization |
| Language Options | English or Chinese GUI (configurable) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS™ DS2500 L |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Time | <40 s per sample |
| Data Sampling Interval | 10 s |
| Measurement Mode | Transmission (for liquids) |
| Chemometrics Software | WinISI |
| IP Rating | IP54 |
| Temperature Control | Automatic, Closed-Loop Sample Thermal Regulation |