FPI
Filter
Showing 61–90 of 163 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-1041 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GT-1121 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GT-2121 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-FL |
| Communication Interface | RS485 Modbus RTU |
| Maximum Node Capacity | 64 detectors per bus |
| Display | None (Bus-Only Variant) |
| Remote Configuration | Infrared bidirectional handheld remote (no cover removal required) |
| Sensor Compensation | Built-in temperature and concentration compensation algorithm |
| Status Indication | Dual-color (red/green) LED |
| Compliance | Designed for industrial hazardous area monitoring per GB 50493, compatible with SIL2-capable control systems |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GT-HF |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GT-IR |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-TL |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GT-TS |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GT-W |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Model | HMA-2000 Series |
| Instrument Type | Online Analyzer |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Lead (Pb), Cadmium (Cd) |
| Detection Time | Zero Drift (24 h): ±5% F.S. |
| Resolution | 0.0001 mg/L |
| Sample Throughput | Continuous online operation with programmable measurement intervals |
| Reagent Consumption | <20% of conventional flow-injection ASV systems |
| Digestion | Sealed high-temperature high-pressure digestion module (up to 180 °C, 2 MPa) |
| Compliance | Designed for ISO 17294-2, EPA Method 200.8, and ASTM D3559–22 compatibility |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HMA-2000 |
| Instrument Type | Online Analytical System |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Pb, Cd, As, or Hg (configurable per unit) |
| Zero Drift | ±5% F.S. |
| Accuracy/Precision | ±10% |
| Resolution | 0.0001 mg/L |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb (µg/L) |
| Precision | RSD ≤ 0.5% |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤ 0.007 nm @ 200 nm |
| Spectral Coverage | Simultaneous multi-element analysis across 72 elements including major metals and non-metals |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ICP-5500 |
| Detector | High-resolution overflow-resistant CCD |
| RF Source | All-solid-state self-excited 27.12 MHz generator |
| Optical System | Precision thermostatically controlled Czerny–Turner monochromator with holographic grating |
| Gas Control | Integrated automatic argon flow management module |
| Standby Mode | iStandby (reduces Ar consumption by >50%) |
| Calibration | Real-time full-spectrum calibration using interference-free Ne emission lines |
| Sample Introduction | Multi-channel high-precision peristaltic pump with integrated nebulizer and spray chamber |
| Compliance | Designed to support ISO/IEC 17025, ASTM D1976, EPA Method 200.7, USP <232>/<233>, and GLP/GMP data integrity requirements |
| Software | FPI-SpectraSuite v4.x with 21 CFR Part 11-compliant audit trail, electronic signatures, and raw data archiving |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IRA-4000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | IRV Series |
| Pricing | Available Upon Request |
| Spectral Response | Short-Wave Infrared (SWIR) |
| Detector Architecture | Scanning Focal Plane Array (FPA) |
| Primary Function | Non-Contact Temperature Measurement |
| Operating Principle | Uncooled Thermal Detection |
| Environmental Suitability | 24/7 Continuous Operation |
| Optical Design | Ruggedized Lens System for Industrial Environments |
| Compliance Basis | Designed to Support ISO 18434-1, ASTM E1934, and IEC 62906-5-2 Guidelines |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LDM-100 |
| Instrument Type | In-Situ Optical Transmissometer for Particulate Emissions Monitoring |
| Extinction Accuracy | ±0.004 |
| Repeatability | ≤2% |
| Response Time | 1–600 s (configurable) |
| Stability | Transmittance/Turbidity ±1% |
| Compliance | Meets GB/T 16157, HJ 76–2017, and HJ 836–2017 requirements for fixed-source emission monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | LGA Series |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA Series |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LGA-3000 Distributed |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-3500 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-4100 HCl/HF |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-4100 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-4500 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | LGA-4500IC |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-5500 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | In-Situ Online Analyzer |
| Technology | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Explosion Protection | Ex d IIB T4 Gb certified |
| Mounting | Flanged in-situ probe configuration |
| Compliance | Designed for industrial process environments per IEC 60079-0/-1/-28 and GB 3836 series |
| Target Gases | CO, CO₂, CH₄, NH₃, HCl, HF, O₂ (configurable via wavelength selection) |
| Operating Ambient Temperature | −20 °C to +60 °C |
| Process Temperature Range | Up to 1800 °C (probe-dependent) |
| Dust Load Tolerance | ≤100 g/m³ |
| Corrosion Resistance | Hastelloy C-276 probe housing standard |
| Power Supply | 24 VDC ±10% or 220 VAC 50/60 Hz |
| Output Interfaces | 4–20 mA analog, RS485 Modbus RTU, Ethernet TCP/IP, optional PROFIBUS DP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-6500 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LGA-8100 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | LGA-9100 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Linearity Error | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Span Drift | ≤ ±1% FS per 6 months |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection Rating | Ex d mb op is px IICT6 Gb |
| Ingress Protection Rating | IP66 |
| Functional Safety Certification | SIL2 compliant |
| Compliance | Designed for continuous emission monitoring and process safety applications in accordance with IEC 61508 and IEC 61511 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LGA-C300 |
| Product Type | Coal Gas Calorific Value Analyzer |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sample Compatibility | Coal gas, coke oven gas, blast furnace gas, and mixed industrial fuel gases |
| Safety Certification Option | ATEX/IECEx-certified explosion-proof probe available |
| Data Output | 4–20 mA, RS485, Modbus TCP, optional OPC UA |
| Compliance Framework | Designed to support GLP/GMP-aligned operational records and ASTM D1826 / ISO 6976–2016–based calorific value calculation protocols |