GBC
Filter
Showing all 21 results
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Argon Humidifier |
| Application | In-line humidification of argon carrier gas for ICP-OES/ICP-MS sample introduction systems |
| Compliance | Designed for integration with ISO/IEC 17025-compliant analytical workflows |
| Regulatory Context | Supports GLP/GMP-aligned sample introduction stability in high-salinity matrix analysis |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra1010 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-Zero |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra2020 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1200 nm |
| Spectral Bandwidth | Adjustable from 1.0 to 5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-zeroing |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra3030 |
| Optical Design | Dual-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | Adjustable from 0.2 nm to 5.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | <0.0005% T at 220 nm and 340 nm |
| Automation Level | Motorized wavelength scanning and slit control |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra4040 |
| Optical Design | True Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Automation | Fully Automatic |
| Slit Width Range | 0.1–2.0 nm |
| Stray Light | <0.0005% T at 220 nm |
| Photometric Linearity | ±1.2% up to 5 Abs |
| Monochromator Configuration | Dual Littrow, Czerny-Turner |
| Dynamic Range | >6 Abs (measured) |
| Compliance | ASTM E275, ISO 6358, USP <857>, EP 2.2.25, JP 2.03 |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Emma |
| Price Range | USD 135,000 – 205,000 (FOB Australia) |
| Instrument Type | Powder X-ray Diffractometer |
| Power Consumption | <0.1 W (standby), <150 W (operational) |
| Beam Geometry | Variable parallel-beam and Bragg–Brentano focusing geometry |
| Sample Stage | Motorized variable-height powder stage + Eulerian cradle (χ, φ, ω rotation) |
| Detector Configuration | Dual fixed-position detectors — one parallel-beam detector with 0.4° Soller slit collimator, one focusing detector with variable slits and graphite monochromator |
| X-ray Source Optics | XOS polycapillary optic delivering 10 × 10 mm quasi-parallel beam |
| parallel-beam radius | 250 mm |
| focusing radius range | 175–250 mm |
| Optional Integrated Detection | Simultaneous XRD/XRF capability via integrated Si-PIN or SDD X-ray fluorescence detector |
| Portability | Modular chassis with integrated handles |
| Goniometer | Harmonic drive-based θ–2θ goniometer with <0.001° angular reproducibility |
| Radiation Safety | Lead-acrylic interlocked viewing window (large-format, wide-field), software-controlled actuation |
| Electronics | Industrial-grade FPGA-based control architecture with GLP-compliant event logging |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | enduro Z-1000 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Adjustable Magnetic Field Strength | 0.6–1.0 T (0.1 T increments) |
| Lamp Holder | 8-position Auto-aligning |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Hollow Cathode & Electrodeless Discharge Lamp Recognition | Encoded |
| Ultra-Lamp Power Supply | 10 V (1 standard, up to 4 optional) |
| Resolution | <0.2 nm |
| Sensitivity | ≤0.003 absorbance units for Cu at 324.8 nm |
| Detection Limit | ≤0.5 pg for Cd in graphite furnace mode |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | FS3000 |
| Sample Capacity | 10 calibration standards + 60 sample positions |
| Dedicated Vial Locations | rinse solution, blank solution, and recalibration standard |
| Programmable Parameters | measurement interval, pre-measurement delay, wash cycle duration, recalibration frequency, restandardization frequency, number of calibration standards, replicate count per sample, first/last sample position indexing |
| Distribution Status | Authorized International Distributor (Imported Equipment) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | HG3000 |
| Type | Continuous-flow hydride generation system for atomic absorption and atomic fluorescence spectroscopy |
| Compatible Elements | As, Sb, Bi, Ge, Pb, Se, Te, Sn, Hg (via cold vapor mode) |
| Detection Capability | Sub-ppb (ng/L) level for all supported elements |
| Sample Throughput | Up to 60 samples/h (triplicate readings) |
| Operating Principle | Acid–sodium borohydride (NaBH₄) reduction in laminar-flow segmented manifold |
| Compliance | Designed to meet ISO/IEC 17025 method validation requirements |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | HG3000PII |
| Type | Continuous-Flow Hydride Generation System |
| Sample Throughput | Up to 60 samples/h |
| Detection Capability | Sub-ppt for As, Bi, Sn, Sb, Te, Se, and Hg |
| Construction | Precision Borosilicate Glass Reaction Manifold |
| Flow Architecture | Segmented Gas-Liquid Flow with Integrated Phase Separation |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC 3000 |
| Pricing | Upon Request |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optimass 9500 |
| Instrument Type | Inductively Coupled Plasma Time-of-Flight Mass Spectrometer |
| Mass Resolution (Unit Mass Resolution at m/z = 238) | 2000 |
| Detection Limit | 1–10 ng·L⁻¹ (ppt level, 3–5 s integration time) |
| Sensitivity | Mcps per ppm |
| Mass Range | 1–260 amu (full-spectrum acquisition) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Optimass 9600 |
| Price Range | USD 420,000 – 700,000 (FOB) |
| Instrument Type | Time-of-Flight Mass Spectrometer (ICP-TOFMS) |
| Mass Resolution (FWHM at 1 amu) | >4000 |
| Detection Limit (in aqueous solution) | <0.1 pg/mL (ppt-level) |
| Sensitivity | >1 × 10⁶ cps per µg/L (Mcps/ppm) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | PS720 |
| Type | Automated Dilution Module for Atomic Absorption Spectroscopy |
| Integration | Designed exclusively for use with GBC SDS720 Autosampler and SavantAA Software |
| Control Interface | Fully integrated via SavantAA v5.0+ |
| Compatibility | Flame AAS (FAAS) and Hydride Generation AAS (HGAAS) |
| Automation Scope | Full dilution, standard addition, internal standard recovery, and up to two chemical modifier additions |
| Mechanical Integration | Synchronized with GBC’s motorized burner head rotation system for extended linear dynamic range |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantima / Integra |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit (Cu) | 0.7 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (RSD) | ≤1.0% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | 0.006 nm (160–200 nm) |
| RF Generator Frequency | 40.68 MHz |
| Argon Consumption (aqueous samples) | <11 L/min |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SavantAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.9 Abs for 5 mg/L Cu solution |
| Repeatability (RSD) | 0.45% |
| Detection Limit | ≤0.003 ppm for Cu |
| Lamp Holder | 8-position Automatic with Auto-Alignment |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Slit Height | Adjustable (Standard & Reduced) |
| Gas Control | Fully Automated with Safety Interlocks |
| D₂ Lamp Lifetime | Up to 10× Longer Than Conventional Lamps |
| Lamp Identification | Encoded HCL & EDL Recognition (Standard on SavantAA Σ, Optional on SavantAA) |
| EDL Power Supply | 10 V Optimized Design (1 Standard on SavantAA & SavantAA Si |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SDS720 |
| Pricing | Available Upon Request |
| Sample Capacity | 360 positions (standard), expandable to 720 |
| Vial Compatibility | 240 × 14 mL vials + 10 × 50 mL standard vials |
| Fluid Path Materials | PTFE and PEEK only (metal-free) |
| Cleaning System | Peristaltic-pump-driven continuous-flow probe wash station |
| Overflow Protection | Fixed overflow tray |
| Instrument Compatibility | GBC XplorAA, SensAA, SavantAA AAS |
| Control Interface | PC-based software with programmable wash time, delay time, replicate injection count, recalibration interval, restandardization cycle, measurement duration, and sequence logic |
| Sampling Mode | Fully random-access sampling |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SensAA |
| Instrument Type | Flame-Graphite Furnace Hybrid AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.8 Abs for 5 mg/L Cu solution |
| Precision (RSD) | ≤0.5% |
| Detection Limit | Cu ≤ 0.005 mg/L |
| Light Source Configuration | 6-target hollow cathode lamp turret enabling up to 13 element combinations |
| Integrated Control | Built-in 15″ Windows-based touchscreen PC |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | System5000 |
| Detection Limit | Sub-ppb for ~50 elements |
| Temperature Range | Up to 3000 °C |
| Sample Volume | 1–100 µL (1 µL increment) |
| Autosampler Capacity | 40 samples + 10 standards |
| Vial Sizes | 2 mL (samples/standards), 5 mL (auto-dilution), 10 mL (reagents/blanks) |
| Graphite Tube | Platform-equipped high-performance tube |
| Gas Control | Programmable purge gas selection (Ar, N₂, or mixed) |
| Chemical Modifier Injection | Dual-channel, software-triggered |
| Syringe Material | Fully PTFE capillary |
| Wash Reservoir | 1 L |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | XplorAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | <0.2 nm |
| Sensitivity | >0.8 A for 5 mg/L Cu solution |
| Precision (RSD) | <0.45% |
| Detection Limit | Sub-ppb for most elements with graphite furnace |
| Software Control | Handheld PC-based interface |
| Lamp Positions | 2 fixed hollow cathode lamp slots |
| Upgrade Path | Field-upgradable to graphite furnace and hydride generation systems |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | MFR 2100 |
| Sample Volume Requirement | ≥100 µL |
| Frequency Range | 0–100 Hz |
| Gap Adjustment Range | 0.6–30 mm |
| Gap Resolution | 0.625 mm |
| Actuation Mode | Pseudo-Random Squeezing (Patented) |
| Data Acquisition | Real-Time Fourier Transform Analysis |
| Control | Fully Automated Computer-Controlled Gap & Sample Handling |