GNR
Filter
Showing all 11 results
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | APD 2000 PRO |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Tube Power | 0.0001 kW (100 W) |
| Radiation Source | Fine-focus Ceramic X-ray Tube |
| Monochromator | Johannson-type Kα₁ monochromator |
| Detector Types | Scintillation Counter & Energy-Dispersive Detector |
| Goniometer Control | Optical Encoder |
| Sample Stage | Motorized Multi-Sample Rotating Stage with Low-Background Options |
| Safety System | Dual Redundant Interlock Circuit |
| Compliance | CE, IEC 61010-1, ISO 9001 |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AreX D |
| X-ray Source | 50 W Mo microfocus tube with Zr filter |
| Cooling | Air-cooled |
| Detection | High-resolution USB camera for precise sample positioning |
| Safety | Interlocked X-ray shielding system |
| Measurable Diffraction Peaks | Austenite (220), (311) |
| Measurement Time | < 3 minutes per sample |
| Compliance | ASTM E975-22 Standard |
| Minimum Detectable Austenite Content | 0.5 vol% |
| Sample Compatibility | Flat, polished metallic specimens (steel, stainless steel, tool steels, bearing alloys) |
| Software | Integrated Windows-based analysis suite with peak integration, phase quantification, and report generation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AREX L |
| Compliance | ASTM E975 |
| Measurement Principle | X-ray Diffraction (XRD) |
| Detection Limit | ≤0.5% austenite |
| Target Material | Ferrous alloys (steel, cast iron, heat-treated components) |
| X-ray Source | High-power ceramic X-ray tube |
| Optics | High-focus single-capillary collimator |
| Detector | High-resolution CCD detector |
| Stability Control | Precision closed-loop feedback circuit for HV/current regulation |
| Data Acquisition | Multi-peak intensity ratio analysis (austenite {220}, {311} / ferrite {200}, {211}) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EDGE |
| Compliance | ASTM E915, EN 15305 |
| Detector | Linear silicon strip detector with single-photon counting technology |
| Cooling | Air-cooled |
| X-ray Source | Interchangeable microfocus X-ray tubes |
| Fluorescence Suppression | Integrated X-ray fluorescence rejection |
| Measurement Time | Minutes per point (vs. hours for conventional systems) |
| Portability | Fully integrated into carry-on compliant transport case |
| Safety Options | Optional radiation shielding enclosure for benchtop operation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EXPLORER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Optical Configuration | Switchable Bragg-Brentano focusing / Johansson monochromator / Parabolic mirror monochromator |
| Beam Geometry | Parallel-beam optics with low-angle reflection capability |
| Thin-film Thickness Detection Range | 1–500 nm |
| Degrees of Freedom for Sample Manipulation | 5 |
| Modular Units | 7 |
| Primary Applications | Phase identification & quantification, crystallite size and microstrain analysis, residual stress measurement, texture analysis, thin-film characterization, depth profiling, nanocrystalline material assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | HORIZON |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to Pu (94) |
| Quantification Range | 10 pg – 100% |
| Energy Resolution | 124 eV (at Mn Kα) |
| Repeatability | ≤ 0.1% RSD |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Sample Type | Ferromagnetic Metals (e.g., carbon steel, alloy steel, cast iron) |
| Portability | Integrated battery-powered handheld system with touch-screen interface and USB connectivity |
| Output | Quantitative residual stress in MPa, graphical trend visualization, calibration curve support |
| Compliance Context | Designed for field-deployable non-destructive evaluation (NDE) in accordance with ASTM E1447, ISO 20956, and EN 10328 guidelines for magnetic methods of stress assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) Analysis |
| Portability | Integrated battery-powered handheld unit with touch display and USB interface |
| Compliance | Designed for field-deployable NDT per ISO 10893-13 and ASTM E3027 guidelines |
| Sample Type | Ferromagnetic metallic components (e.g., bearing races, gear teeth, camshafts, turbine blades) |
| Output | Real-time MBN amplitude & frequency spectrum, quantitative burn index, pass/fail classification |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | S5 |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Focal Length | 500 mm |
| Groove Density | 3600 lines/mm |
| Wavelength Range | 130–900 nm |
| Detection Mode | Full-Spectrum CCD |
| Vacuum Optical Chamber | Integrated, Sealed |
| Elemental Coverage | C, P, S, N, Al, Ni, Cr, Mn, Cu, Mo, V, Ti, Co, Nb, W, Sn, Pb, Zn, Mg, Ca, Si, Fe, As, Bi, Sb, etc. |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | STRESS-X |
| Compliance | ASTM E915, EN 15305 |
| Motion System | 6-axis robotic arm |
| Deployment Options | Benchtop shielded enclosure or mobile four-wheel alloy cart |
| Measurement Principle | Sin²ψ X-ray diffraction (XRD) |
| Application Scope | Non-destructive residual stress mapping on metallic components |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | TX 2000 |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to Pu (94) |
| Quantification Range | 10 pg – 100% |
| Energy Resolution | 124 eV (at Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Peltier-cooled Silicon Drift Detector (SDD) |
| Excitation Source | Switchable Mo/W anode X-ray tube |
| Angular Control | High-precision optical encoder stepper motor |