HAMILTON
Filter
Showing all 5 results
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Model | GFGJ-81000 |
| Capacity | 10–500 µL |
| Needle Gauge Options | 26s (OD 0.47 mm, ID 0.13 mm), 22s, 22 (OD 0.72 mm, ID 0.41 mm), 25 |
| Needle Length | 2 in (51 mm) |
| Volume per Inch (26s) | 0.26 µL/in |
| Volume per Inch (22) | 3.35 µL/in |
| Type | N-type (fixed needle, gas-tight plunger seal) |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Model | 243632 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Calibration | Standard pH Buffer Solutions |
| Brand | Hamilton |
|---|---|
| Origin | Switzerland |
| Model | H100 pH |
| Measurement Range | pH −2.00 to 16.00 |
| ORP | −1500 to +1500 mV |
| Temperature Input | Pt100 / Pt1000 / NTC 30 kΩ |
| Temperature Range | −20 to +150 °C |
| Temperature Resolution | 0.1 °C |
| Measurement Error | <1 mV |
| Analog Outputs | Dual 4–20 mA (floating, max 10 V) |
| Relay Output | Configurable (alarm/flush), 3 A / <250 VAC or 30 VDC |
| Housing Material | PBT |
| Enclosure Rating | IP65 / NEMA 4X |
| Power Supply | 24–230 V AC/DC |
| Display | 7-segment LCD with icons |
| Operating Humidity | 0–80% RH at ≤55 °C |
| FM Certification | Class I, Div. 2, Groups A/B/C/D & IIC, T4, Ta = 55 °C, Type 2 |
| Brand | Hamilton |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HB42VP |
| Instrument Type | Inline / Process pH Sensor |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | pH 0–14 |
| Resolution | 0.01 pH |
| Accuracy | ±0.15 pH |
| Calibration | Standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01) |
| Electrolyte System | Polisolve polymer electrolyte |
| Reference System | Polilyte polymer reference |
| Connection | VarioPin (VP) quick-fit connector |
| Glass Membrane | High-pH-resistant glass with low alkaline error |
| Temperature Compensation | Integrated Pt1000 RTD |
| Operating Pressure | Up to 6 bar (gauge), non-compensated |
| IP Rating | IP68 (when properly mounted in compatible housing) |
| Brand | HAMILTON |
|---|---|
| Stationary Phase | PSDVB/Trimethylammonium |
| Mode | Anion Exchange |
| Particle Size | 10 µm |
| Pore Size | 100 Å |
| Inner Diameter | 4.1 mm |
| Length | 250 mm |
| Housing Material | Stainless Steel |
| Max. Pressure | 5,000 psi |
| Exchange Capacity | 0.304 meq/column |
| pH Stability Range | 1–13 |
| Mobile Phase Compatibility | 0–100% aqueous/organic (e.g., methanol, acetonitrile) |
| Temperature Limit | 60 °C (at pH 1–7), 50 °C (at pH 8–13) |
| Regeneration Protocol | 50 mL methanol + 1% v/v 6 N HNO₃ |