| Brand | Hanna Instruments |
|---|---|
| Model | HI932 |
| Instrument Type | Universal Potentiometric Titrator |
| pH Range | –2.000 to 20.000 (selectable resolution: 0.001 / 0.01 / 0.1 pH) |
| mV Range | –2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV (@25°C) |
| ISE Range | 1×10⁻⁶ to 9.99×10¹⁰ |
| ISE Accuracy | ±0.5% (monovalent), ±1% (divalent) |
| Temperature Range | –5.0 to 105.0 °C |
| Temperature Accuracy | ±0.1 °C (@25°C, excluding probe error) |
| Burette Resolution | 1/40000 |
| Dispensing Accuracy | ±0.1% of full burette volume |
| Display | 5.7″ color LCD (320 × 240 px) |
| GLP Compliance | Full audit trail, timestamped method & result storage, user access control |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98197 |
| Portability | Handheld |
| Application | Laboratory & Field Use |
| Conductivity (EC) | 0.001 to 999.9 µS/cm |
| TDS | 0.00 to 999.9 mg/L (ppm) |
| Resistivity | 1.0 to 100.0 MΩ·cm |
| Temperature | −20.0 to 120.0 °C |
| Accuracy (EC) | ±1% of reading or ±0.01 µS/cm (whichever is greater) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98318 |
| Instrument Type | Portable |
| Parameter Type | Multi-Parameter (EC, TDS, Temperature) |
| Measurement Range | EC: 0.00 to 6.00 mS/cm |
| TDS | 0 to 3000 ppm (500 CF), 0 to 3999 ppm (700 CF) |
| Resolution | EC: 0.01 mS/cm |
| TDS | 10 ppm (mg/L) |
| Temperature | 0.1 °C / 0.1 °F |
| Accuracy | ±2% F.S. @ 20°C/68°F |
| Calibration | Automatic single-point recognition (1.41 mS/cm or 5.00 mS/cm) |
| Temperature Compensation | Automatic, β = 1.9 %/°C |
| TDS Conversion Factors | 0.50 (500 ppm), 0.70 (700 ppm) |
| Operating Environment | 0 to 50°C, RH ≤ 100% |
| Power | 4 × 1.5 V button cells (LR44) |
| Dimensions | 163 × 40 × 26 mm |
| Weight | 100 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI83300 |
| Measurement Principle | Dual-mode spectrophotometric and electrochemical detection |
| Total Parameters | >55 pre-programmed water quality methods |
| Wavelength Range | 380–760 nm (visible spectrum) |
| Optical System | Fixed-wavelength LED-based photometry with precision interference filters |
| Detector | Silicon photodiode |
| Resolution | Up to 0.001 mg/L (depending on parameter) |
| Accuracy | ±2–8% of reading + offset (method-specific, per ISO 8466-1 and ASTM D511/D129/D3370) |
| Operating Temperature | 10–40 °C |
| Power | Rechargeable Li-ion battery (up to 12 h continuous use) or AC adapter |
| Data Storage | 1000 measurement records with timestamp, sample ID, and operator ID |
| Connectivity | USB port for data export (CSV format), no Bluetooth/Wi-Fi |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible operation |