| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GXH-3010/3011AE |
| Instrument Type | Portable |
| Detection Target | Multi-component |
| Minimum Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time | ≤30 s |
| Zero Drift | ≤±2% F.S./4 h |
| Span Drift | ≤±2% F.S./4 h |
| Linearity Error | ≤±2% F.S. |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Sampling Method | Built-in Pump-aspiration |
| Flow Rate | 0.5–1.2 L/min |
| Power Supply | AC 220 V (±10%) or Rechargeable Battery |
| Dimensions | 260 × 210 × 90 mm |
| Weight | ≤3.5 kg |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010/3011BF |
| Instrument Type | Portable |
| Detection Target | Multi-component |
| Minimum Range | (0–50.0) × 10⁻⁶ CO, 0–0.500% CO₂ |
| Repeatability | ≤1% FS |
| Resolution | 0.1 × 10⁻⁶ CO |
| Response Time | CO: t₀–t₉₀ ≤45 s |
| CO₂ | t₀–t₉₀ ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| Brand | Huayun |
|---|---|
| Model | GXH-3010D |
| Type | NDIR-based Fixed Gas Analyzer |
| Measurement Principle | Gas Filter Correlation (GFC) Infrared Spectroscopy |
| Measurands | CO, CO₂, Hydrocarbons (HC) |
| Range | 0–100% vol (user-selectable sub-ranges) |
| Repeatability | ≤1% FS |
| Warm-up Time | ≤30 min |
| Response Time (T90) | ≤10 s |
| Output | 4–20 mA analog + RS-232/RS-485 digital interface |
| Temperature Control | Internal thermostatic stabilization |
| Compliance | JJG 635–1999, GB/T 18204.24–2000 |
| Enclosure | Customizable compact chassis (standard or application-specific rackmount) |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010F |
| Instrument Type | Portable |
| Detection Target | Single-component gas |
| Measurement Range | 0–0.500% CO₂ (customizable up to 0–20.00%) |
| Repeatability | ≤1% FS |
| Resolution | 0.001% CO₂ |
| Response Time | t₀–t₉₀ ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| Temperature Effect | ≤±2% FS/10°C (10–45°C) |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Power Supply | AC 220 V (±10%) or internal rechargeable battery |
| Dimensions | 255 × 215 × 92 mm |
| Weight | ≤3.2 kg |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010H (with One-Touch Zero Calibration) |
| Instrument Type | Portable |
| Detection Target | Single-Component Gas |
| Measurement Range | 0–0.500% CO₂ (expandable to 0–1.000%) |
| Repeatability | ≤1% of Full Scale |
| Resolution | 0.001% |
| Response Time (t₀–t₉₀) | ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| Sampling Method | Integrated Pump-Aspiration |
| Flow Rate | 0.5–1.0 L/min |
| Warm-up Time | ≤10 min |
| Operating Temperature | 10–45 °C |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Power Supply | AC 220 V (±10%) or Rechargeable Li-ion Battery |
| Dimensions | 200 × 95 × 35 mm |
| Weight | ≤500 g |
| Compliance | GB/T 18204.2–2014, GBZ/T 300.37–2017, JJG 635–2011 |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GXH-3011A1 |
| Instrument Type | Portable |
| Detection Target | Single-component (CO) |
| Measurement Range | 0–50 ppm |
| Resolution | 0.1 ppm |
| Repeatability | ≤1% F.S. |
| Response Time | ≤60 s (t₀–t₉₀ ≤45 s) |
| Zero Drift | ≤±2% F.S./3 h |
| Span Drift | ≤±2% F.S./h |
| Linearity Error | ≤±2% F.S. |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Dimensions | 245 × 190 × 85 mm |
| Weight | ≤3 kg |
| Data Storage | Up to 5,000 records |
| Interface | USB with dedicated data transfer software |
| Preheat Time | ≤30 min |
| Flow Rate | 0.5–1.0 L/min |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GXH-3011B |
| Instrument Type | Portable |
| Detection Target | Single-component gas (CO) |
| Minimum Measurement Range | (0–50.0) × 10⁻⁶ (v/v) |
| Repeatability | ≤1% of full scale |
| Resolution | 0.1 × 10⁻⁶ (v/v) |
| Response Time | t₀–t₉₀ ≤ 45 s |
| Zero Drift | ≤±2% of full scale per hour |
| Span Drift | ≤±2% of full scale per 3 hours |
| Linearity Error | ≤±2% of full scale |
| Warm-up Time | ≤30 min |
| Flow Rate | 0.5–1.0 L/min |
| Data Storage Capacity | Up to 30,000 records |
| Power Supply | AC 220 V (±10%) or rechargeable internal Li-ion battery |
| Dimensions | 255 × 215 × 92 mm |
| Weight | ≤3.9 kg |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GXH-3011N |
| Instrument Type | Online |
| Detection Target | Single-component |
| Minimum Range | CO (0–500) × 10⁻⁶ |
| Repeatability | ≤ ±1% FS |
| Resolution | ≤ ±1% FS |
| Response Time | t₀–t₉₀ ≤ 30 s (from sample gas entry) |
| Zero Drift | ≤ ±2% FS / 72 h |
| Span Drift | ≤ ±2% FS / 72 h |
| Linearity Error | ≤ ±2% FS |