IKA
Filter
Showing 121–150 of 485 results
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | EUROSTAR 60 digital |
| Instrument Type | Electric Overhead Stirrer |
| Max. Mixing Volume | 60 L (H₂O) |
| Speed Range | 0/30–2000 rpm |
| Max. Viscosity | 50,000 mPa·s |
| Max. Torque (Low Speed) | 100 N·cm |
| Max. Torque (High Speed) | 60 N·cm |
| Torque Measurement Accuracy | ±6 N·cm |
| Display | LCD |
| Interfaces | USB-C, RS232 |
| Protection Rating | IP54 |
| Compliance | ISO Class 7/8 Cleanroom Certified |
| Motor Type | Brushless DC |
| Continuous Duty Cycle | 100% |
| Dimensions (W×H×D) | 89 × 237 × 191 mm |
| Weight | 3.8 kg |
| Ambient Temp. Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % |
| Power Supply | 100–240 V, 50/60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Eurostar Power Control P4/P7 |
| Speed Control | Stepless (0–2000 rpm) |
| Torque Range | Up to 150 N·cm (P4), Up to 300 N·cm (P7) |
| Display | Dual digital display (set speed & actual speed, torque & viscosity estimation) |
| Interface | RS232 |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4 |
| Safety Features | Overload protection, soft-start circuitry, thermal cut-off, non-penetrating shaft design |
| Software Compatibility | labworldsoft® (v5.0+) for remote control, real-time data logging, and audit-trail-enabled operation |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Eurostar Power Control |
| Instrument Type | Digital Overhead Stirrer (Viscometric) |
| Max. Mixing Volume | 40 L |
| Speed Range | 20–2000 rpm |
| Speed Control | Microprocessor-based, Stepless (No Gear Shifting) |
| Torque Monitoring | Yes |
| Interface | RS232 |
| Display | Digital (Set & Actual Speed), Analog Torque Output |
| Safety Features | Electronic Overload Protection, Safe Start-up Logic, Integrated Safety Circuit |
| Drive Design | Penetrating Shaft (Through-Drive), Low-Noise Brushless Motor |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | G-L |
| Maximum Speed | 15,700 rpm |
| Rotor Capacity | 12 × 1.5/2.0 mL tubes |
| Relative Centrifugal Force (RCF) | 16,500 × g |
| Acceleration Time to Max Speed | 17 s |
| Deceleration Time from Max Speed | 18 s |
| Speed Accuracy | ±100 rpm |
| Speed Deviation | ±2.5% |
| Timer Range | Yes (LED display) |
| Unbalance Detection | Yes |
| Quick-Stop Function | Yes |
| Auto-Lid Opening | Yes |
| Safety Lid Interlock | Yes |
| Noise Level | 55 dB(A) |
| Dimensions (W × D × H) | 200 × 140 × 280 mm |
| Weight | 3.9 kg |
| Operating Ambient Temperature | +5 to +40 °C |
| Max. Relative Humidity | 80% (non-condensing) |
| Protection Class | IP20 (DIN EN 60529) |
| Power Supply | 220–230 V, 50/60 Hz |
| Input Power | 92 W (operational), 3 W (standby) |
| USB Interface | Yes |
| Display Unit Conversion | rpm ↔ RCF |
| Motor Type | Brushless DC |
| Rotor Material | Anodized aluminum alloy |
| Compliance | CE, IEC 61010-1, IEC 61010-2-020 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Benchtop Centrifuge |
| Speed Range | 800 – 15,700 rpm |
| Max RCF | 16,500 × g |
| Max Capacity | 12 × 1.5/2.0 mL tubes |
| Rotor Compatibility | Fixed-angle rotor (autoclavable at 121 °C, 2 bar) |
| Dimensions (W×D×H) | 200 × 140 × 280 mm |
| Weight | 3.9 kg |
| Power Supply | 220–230 V / 115 V / 100 V, 50/60 Hz |
| Input Power | 92 W (operational), 18 W (standby) |
| Protection Class | IP20 (DIN EN 60529) |
| Operating Environment | +5 to +40 °C, ≤80% RH |
| Safety Features | Lid interlock, imbalance detection, rapid brake, automatic lid opening |
| Display | LED, 7-segment |
| Control Interface | Membrane keypad with RPM/RCF toggle |
| USB Port | Yes |
| Timer | Yes |
| Rotor Auto-Recognition | No |
| Balance Monitoring | Yes |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Import |
| Model | HABITAT cell |
| Vessel Material | Borosilicate Glass |
| Working Volume Range | 0.5–10 L (configurable via vessel options) |
| Gas Control | 4-channel MFCs (Air, O₂, N₂, CO₂) |
| Flow Range | 0–2000 cc/min per channel |
| Peristaltic Pumps | 4 × Watson Marlow 114DV heads |
| Stirring Speed | 1–2200 rpm |
| Temperature Control | Heating blanket (250 W) or external thermostat interface |
| pH Range | 0–14 |
| Accuracy | ±0.02 pH |
| DO Range | 0–200 %sat |
| Resolution | 0.01 %sat |
| Accuracy | ±0.3 %sat |
| Temp Control Range | 5–60 °C (heating blanket) |
| Data Storage | 32 GB internal SSD |
| Compliance Options | FDA 21 CFR Part 11–compliant software module available |
| Enclosure Rating | IP20 |
| Power Input | 100–240 V, 50/60 Hz |
| Max Power Consumption | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Integrated Control Tower Bioreactor System |
| Reactor Volume Range | 0.5–10 L |
| Temperature Range | 0–100 °C |
| Sterilization Method | Autoclavable (121 °C, 20 min) |
| Number of Independent Gas Channels | 4 (Air, O2, N2, CO2) |
| Mass Flow Control Range | 0–2000 cc/min per channel |
| Integrated Peristaltic Pumps | 4 (Watson-Marlow 114DV) |
| Stirring Speed Range | 1–2200 rpm |
| pH Measurement Range | 0–14 pH (±0.02 pH accuracy) |
| Dissolved Oxygen Range | 0–200 %sat (±0.3 %sat accuracy) |
| Conductivity & Turbidity Sensor Interfaces | Yes |
| CO₂ Sensor Interface | Yes |
| Chaotic Mixing Mode | Yes |
| Heating Blanket Power | 250 W |
| Data Storage Capacity | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external pump/thermostat/single-use reactor interfaces |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Type | Integrated Control Tower Fermenter System |
| Vessel Capacity | 0.5–10 L |
| Aeration | Four Independent Mass Flow Controlled Gas Lines (Air, O2, N2, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200 % saturation |
| Accuracy | ±0.3 % sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing Mode + Standard Profile/Cascade Modes |
| Speed Range | 1–2200 rpm |
| Reversibility | Yes |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (Acid, Base, Antifoam, Feed) |
| Flow Range | 1–270 mL/min |
| Data Management | 32 GB internal storage, Ethernet, USB, RS232, Wi-Fi, FDA 21 CFR Part 11-compliant software option available |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Benchtop Bioreactor with Integrated Control Tower |
| Vessel Capacity | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (Air, O2, N2, CO2) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing mode + conventional profile/Cascade control |
| Speed range | 1–2200 rpm |
| Reversibility | Yes |
| Sensors Supported | pH, DO, temperature, level, foam, CO₂, conductivity, turbidity |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Flow range | 1–270 mL/min |
| Software | Touch-enabled tablet interface (10.4″), real-time data logging, calibration management, FDA 21 CFR Part 11-compliant version optional |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external thermostat & pump interfaces |
| Enclosure Rating | IP20 |
| Power | 100–240 V AC, 50/60 Hz |
| Max. input power | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HABITAT |
| Dimensions (W×H×D) | 224 × 624 × 405 mm |
| Stirring Speed Range | 1–2200 rpm |
| Peristaltic Pump Heads | 4 (acid, base, antifoam, level) |
| Pump Flow Rate | 1–270 mL/min |
| Gas Flow Rate | 0–2 L/min (CELL/CCT) |
| Mass Flow Controllers (MFCs) | 4 (Air, O₂, N₂, CO₂) |
| Controlled Parameters | Agitation, Aeration, Liquid Feed, Off-gas Analysis, Temperature, pH, Dissolved Oxygen (DO), Foam, Level, Conductivity, CO₂, Turbidity, Light |
| Interfaces | USB, RS-232, Ethernet, SU Connection, Chiller Interface, External Pump Control, 4–20 mA Analog I/O |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Product Type | Photobioreactor System |
| Model | HABITAT photo cell |
| Construction Material | Borosilicate Glass (DIN ISO 3585) |
| Regulatory Compliance | CE, RoHS, IP20 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 224 × 624 × 405 mm |
| Weight | 14 kg |
| Operating Ambient | 5–40 °C, ≤80% RH (at 31 °C), linearly decreasing to 50% at 40 °C |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | HABITAT Photo Cell CCT |
| Instrument Classification | Photobioreactor / Lab-Scale Controlled Bioreactor |
| Vessel Material | Borosilicate Glass (DIN ISO 3585) |
| Dimensions (W×D×H) | 224 × 624 × 405 mm |
| Weight | 14 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Max. Input Power | 1100 W |
| IP Rating | IP20 |
| Environmental Operating Conditions | 5–40 °C, ≤80% RH (at 31 °C), linearly decreasing to 50% RH at 40 °C |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Model | HABITAT Photo Ferment CCT |
| Vessel Volume | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (N₂, O₂, air, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring Speed | 1–2200 rpm |
| Speed Deviation | ±2% (≥100 rpm), ±5 rpm (<100 rpm) |
| LED Illumination | Adjustable intensity & timing for circadian simulation |
| Chaotic Mixing Mode | Enabled |
| Integrated Peristaltic Pumps | 4 Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Data Storage | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Interfaces | Ethernet, USB, RS232, external pump/thermostat/single-use reactor ports |
| Protection Rating | IP20 |
| Power Input | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HABITAT photo ferment |
| Vessel Volume | 0.5–10 L |
| Aeration System | Integrated 4-channel mass flow controllers (N₂, O₂, air, CO₂) |
| pH Control | Range 0–14, Accuracy ±0.02 |
| Dissolved Oxygen (DO) Control | Range 0–200% saturation, Accuracy ±0.03% |
| Temperature Control | Range 0–100 °C, Accuracy ±0.2 °C |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | HB digital |
| Price | ¥15,300 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | HB eco |
| Price | ¥10,200 |
| Heating Power Output | 1400 W |
| Temperature Range | Ambient to 99 °C |
| Temperature Control | Analog Knob |
| Temp. Control Accuracy | ±1 K |
| Temperature Fluctuation (3 L water at 99 °C) | ±1 K |
| Avg. Absolute Deviation (3 L water at 99 °C) | ±2 K |
| Max. Bath Capacity | 4 L |
| Minimum Fill Level | 60 mm |
| Wetted Materials | Stainless Steel 1.4404 (AISI 316L) |
| Fixed Safety Cut-off | 109 °C (DIN 12876 Class I) |
| External Diameter | 257 mm |
| Internal Diameter | 225 mm |
| External Height | 190 mm |
| Internal Depth | 130 mm |
| Overall Dimensions (W × D × H) | 330 × 190 × 325 mm |
| Weight | 3.9 kg |
| Ambient Operating Temperature | 5–40 °C |
| Max. Relative Humidity | 80 % |
| Ingress Protection | IP21 (DIN EN 60529) |
| USB Interface | Yes |
| Voltage | 200–240 V / 100–120 V |
| Frequency | 50/60 Hz |
| Rated Input Power | 1450 W |
| Standby Power Consumption | 3 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Heating Circulator |
| Circulation Mode | Internal & External |
| Temperature Control | Heating-Only |
| Bath Volume | 8–11 L |
| Temperature Range | 10–200 °C (extended to 250 °C with oil) |
| Temperature Stability | ±0.02 K |
| Input Power | 2650 W |
| Supply Voltage | 230 V AC, 50/60 Hz |
| Protection Class | IP21 |
| Compliance | DIN 12876 Class III (FL), EN 60529, CE |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HBC 10 control |
| Instrument Type | Water/Oil Bath Circulator |
| Circulation Mode | Internal & External |
| Temperature Control | Heating-Only |
| Bath Volume | 8–11 L |
| Temperature Range | 10–200 °C |
| Temperature Stability | ±0.01 K |
| Input Power | 2650 W |
| Supply Voltage | 230 V |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | HBC 5 basic |
| Temperature Range | 10–200 °C |
| Temperature Stability | ±0.02 K |
| Bath Volume | 4.5–6.5 L |
| Heating Power | 2650 W |
| Voltage | 230 V AC, 50/60 Hz |
| Circulation Type | Internal & External |
| Protection Class | IP21 |
| Compliance | DIN 12876 Class III (FL), DIN EN 60529 |
| Interface | RS232 & USB |
| Display | Large LED with dual temperature readout (process & safety) |
| Pump Type | Integrated pressure/suction pump |
| Max. Pressure | 0.61 bar |
| Max. Suction | 0.45 bar |
| Max. Flow Rate | 31 L/min at 0 bar backpressure |
| Cooling Coil | Integrated |
| Safety Features | Dual PT100/PT1000 sensors, adjustable safety limit (0–260 °C), visual & audible alarms, overpressure protection, secondary thermal cutoff |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | HBC 5 control |
| Instrument Type | Water/Oil Bath Circulator |
| Circulation Mode | Internal & External |
| Temperature Control | Heating-Only |
| Bath Volume | 4.5–6.5 L |
| Temperature Range | 10–250 °C |
| Temperature Stability | ±0.01 K |
| Input Power | 2650 W |
| Supply Voltage | 230 V |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Model | HBR 4 control |
| Heating Power | 1000 W |
| Max. Bath Volume | 4 L |
| Temp. Range | RT to 200 °C |
| Temp. Control Accuracy | ±1 K (water, 3 L @ 90 °C) / ±2 K (silicone oil, 3 L @ 150 °C) |
| Stirring Speed Range | 150–800 rpm |
| Stirring Motor Output | 1 W |
| Safety Cut-off Range | 50–210 °C |
| Protection Class | DIN 12877 Class II |
| IP Rating | IP20 |
| Dimensions (W×D×H) | 340 × 250 × 340 mm |
| Weight | 4.4 kg |
| Power Supply | 230/115/100 V, 50/60 Hz |
| Interface | RS 232 |
| External Sensor Support | PT1000 |
| Material (Wetted Parts) | Stainless Steel 1.4301 (AISI 304) |
| Minimum Fill Level | 20 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HBR 4 control |
| Heating Power | 1000 W |
| Max. Bath Volume | 4 L |
| Temp. Range | RT to 200 °C |
| Temp. Control Accuracy | ±1 K (water, 90 °C) / ±2 K (silicone oil, 150 °C) |
| Stirring Speed Range | 150–800 rpm |
| Safety Temp. Range | 50–210 °C |
| Display | Digital LCD (set temp., actual temp., safety temp., speed) |
| Interface | RS 232 |
| External Sensor Support | PT1000 |
| Protection Class | IP20 |
| Dimensions (W×D×H) | 340 × 250 × 340 mm |
| Weight | 4.4 kg |
| Power Supply | 230/115/100 V, 50/60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Heating and Cooling Circulating Bath |
| Model | HRC 2 lite |
| Bath Volume | 3.5 L |
| Temperature Range | –10 to 100 °C |
| Temperature Stability | ±0.1 K (per DIN 12876, at +70 °C and –10 °C) |
| Pump Type | Pressure/Suction Circulation Pump |
| Max. Pump Pressure | 0.35 bar |
| Max. Flow Rate | 18 L/min (at 0 bar backpressure) |
| Heating Power | 1000 W |
| Cooling Capacity | 400 W (@ 20 °C), 350 W (@ 10 °C), 250 W (@ 0 °C), 100 W (@ –10 °C) |
| Refrigerant | R290 (propane, natural hydrocarbon) |
| Refrigerant Charge | 72 g |
| Max. Refrigerant Pressure | 21 bar |
| Control Sensor | PT1000 (dual: operational + safety) |
| Temperature Display | LED, resolution 0.1 K |
| Safety Features | Adjustable overtemperature/undertemperature cutoff (0–110 °C), visual & audible alarms |
| Compliant with | DIN 12876 Class II, DIN EN 60529 IP21, CE, RoHS |
| Power Supply | 230 V, 50/60 Hz |
| Input Power | 1250 W |
| Noise Level | 51 dB(A) |
| Dimensions (W×D×H) | 225 × 385 × 430 mm |
| Weight | 24.9 kg |
| Ambient Operating Conditions | 5–32 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Model | HRC2 green basic |
| Temperature Range | −30 °C to +100 °C |
| Temperature Stability | ±0.051 K (DIN 12876, @+70 °C and @−10 °C) |
| Heating Power | 1500 W (230 V) |
| Cooling Capacity | 620 W (@20 °C), 600 W (@10 °C), 480 W (@0 °C), 350 W (@−10 °C), 200 W (@−20 °C), 80 W (@−30 °C) |
| Refrigerant | R290 (propane), GWP ≈ 3 |
| Pump Type | Dual-mode PEEK diaphragm pump (pressure/suction), 0–4000 rpm continuous adjustment |
| Max. Pressure | 0.5 bar |
| Max. Suction | 0.25 bar |
| Max. Flow Rate | 21 L/min (at 0 bar backpressure) |
| Bath Volume | 1.4–4.0 L |
| Safety Class | DIN 12876 Class III (FL), for flammable and non-flammable liquids |
| Protection Rating | IP21 |
| Interface | RS232, Micro-USB |
| Dimensions (W×D×H) | 220 × 480 × 525 mm |
| Weight | 26 kg |
| Ambient Operating Conditions | 5–32 °C, ≤80 % RH |
| Noise Emission | 58 dB(A) |
| Certifications | CE, compliant with EN 61010-1, EN 61326-1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | HRC2 green control |
| Temperature Range | −30 °C to +100 °C |
| Internal Temp Stability (@+70 °C, water) | ±0.05 K |
| Heating Power | 1500 W (230 V) |
| Cooling Capacity | 620 W (@20 °C), 600 W (@10 °C), 480 W (@0 °C), 350 W (@−10 °C), 200 W (@−20 °C), 80 W (@−30 °C) |
| Refrigerant | R290 (79 g, GWP < 3) |
| Max Pressure | 21 bar |
| Pump Type | Variable-speed PEEK pressure/suction pump |
| Flow Rate | 0–21 L/min (adjustable, 2000–4000 rpm) |
| Max Pressure at Zero Flow | 0.5 bar |
| Bath Volume | 1.4–4.0 L |
| Display | LED, resolution 0.01 K |
| External PT100 Sensor Input | Yes |
| Safety Features | Dual PT100/PT1000 sensors, adjustable safety cutoff (0–110 °C), overpressure protection, secondary safety circuit, audible/visual alarms |
| Compliance | DIN 12876 Class III, DIN EN 60751 Class A (PT100), IP21, CE, RoHS |
| Interfaces | RS232, Micro-USB, analog output (0–10 V), digital alarm outputs (30 V AC/DC, 1 A), solenoid valve output (24 V DC, 0.8 A), 5 V DC auxiliary input |
| Noise Level | 58 dB(A) |
| Dimensions (W×D×H) | 220 × 480 × 525 mm |
| Weight | 26.5 kg |
| Ambient Operating Conditions | 5–32 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HS 260 basic |
| Instrument Type | Reciprocal Shaker |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Temperature Control | None |
| Platform Quantity | 1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 basic |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Platform Quantity | 1 |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Input Power | 45 W |
| Dimensions (W×H×D) | 360 × 420 × 100 mm |
| Weight | 8.5 kg |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 |
| Voltage | 220–240 V / 100–120 V, 50/60 Hz |
| Motor Output Power | 10 W |
| Minimum Adjustable Speed | 20 rpm |
| Display | LED for speed and timer |
| Operation Modes | Timed or continuous |
| Platform Type | Flat reciprocating platform |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 control NOL |
| Timer Range | 1–599 min |
| Oscillation Frequency | 10–300 rpm |
| Stroke Diameter | 20 mm |
| Temperature Range | 5–50 °C |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 45 W |
| Protection Rating | IP21 |
| Interface | RS232, Analog Output |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.8 kg |
| Ambient Operating Conditions | 5–50 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HS 260 control |
| Instrument Type | Reciprocal Shaker |
| Timer Range | 1–599 min |
| Oscillation Frequency | 10–300 rpm |
| Stroke Length | 20 mm |
| Temperature Control | None |
| Platform Quantity | 1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 control |
| Timer Range | 1–599 min |
| Oscillation Frequency | 10–300 rpm |
| Stroke Length | 20 mm |
| Temperature Range | 5–50 °C |
| Platform Quantity | 1 |
| Max Load Capacity | 7.5 kg |
| Display | LCD (speed & timer) |
| Control Interface | RS-232, analog output |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 45 W |
| Protection Rating | IP21 |
| Dimensions (W×H×D) | 360 × 100 × 420 mm |
| Weight | 8.8 kg |
| Ambient Operating Conditions | 5–50 °C, ≤80 % RH |