Jiada Xiaotian’e
Filter
Showing 1–30 of 35 results
| Brand | Jiada Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Water Quality Analyzer |
| Model | GDYS-103SF2 |
| Detection Parameter | Anionic Surfactants (e.g., LAS, AES) |
| Detection Limit | 0.1 mg/L |
| Measurement Range | 0.0–3.0 mg/L |
| Accuracy | ±5% |
| Analysis Time | ≤5 min per sample |
| Reagent Format | Single-use, pre-packaged test kits |
| Compliance | Designed for field-deployable compliance screening per GB/T 5750.4–2023 (China Standard for Drinking Water Quality — Determination of Anionic Surfactants) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Aquaculture Water Rapid Test Kit |
| Price Range | USD 140–1,400 (based on configuration) |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Method |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYJ-201MC |
| Principle | Colorimetric Method |
| Measurement Ranges | Adhesives: 0.00–1.25 g/kg |
| Furniture & Engineered Wood | 0.0–5.0 mg/L (Desiccator Method) |
| Detection Limits | Adhesives: 0.01 g/kg |
| Furniture & Engineered Wood | 0.1 mg/L (Desiccator), 0.1 mg/100g (Perforator), 0.05 mg/m³ (Climate Chamber) |
| Accuracy | ±5% |
| Light Source | High-Brightness LED |
| Wavelength | 412 nm |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Rechargeable Battery | 7.4 V, 900 mAh |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYJ-201SC |
| Price Range | USD 1,400–2,800 (estimated) |
| Measurement Principle | Colorimetric Method |
| Detection Limit | 0.05 mg/L |
| Measurement Range | 0.00–5.00 mg/L |
| Accuracy | ±5% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded Microcontroller |
| Data Functions | Real-time measurement, parameter setting, data logging, statistical analysis, USB communication |
| Sample Prep | Dedicated extraction apparatus + single-use reagent kits |
| Compliance | GB 18580–2001, GB 18584–2001 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYJ-201SY |
| Detection Limit | 5.00 mg/kg |
| Measurement Range | 0.00–500.00 mg/kg |
| Accuracy | ±5% |
| Compliance | GB/T 2912.1–1998, GB 18401–2001 |
| Analysis Time | ≤15 min per sample |
| Display | Backlit LCD with Chinese interface |
| Control System | Embedded microcontroller |
| Data Functions | Measurement logging, statistical processing, configuration, help, and RS232 communication |
| Sample Prep | Dedicated extraction apparatus + single-use reagent kits |
| Quantitative Output | mg/kg (formaldehyde content in fabric) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-102S |
| Light Source | High-Brightness LED |
| Wavelength | 635 nm |
| Detection Limit | 0.005 mg/m³ |
| Measurement Range | 0.000–0.100 mg/m³ (40 L sampling volume) or 0.000–0.800 mg/m³ (5 L sampling volume) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-211M |
| Detection Principle | Colorimetric Method |
| Measurement Range | Formaldehyde: 0.00–1.00 mg/m³ |
| BTEX (Benzene, Toluene, Ethylbenzene, Xylenes) | 0.00–1.00 mg/m³ |
| TVOC | 0.00–4.00 mg/m³ |
| Detection Limit | Formaldehyde: 0.01 mg/m³ |
| BTEX | 0.05 mg/m³ |
| TVOC | 0.05 mg/m³ |
| Accuracy | ±5% |
| Power Supply | 9 V alkaline battery (≥40 h continuous operation) |
| Auto-power-off | After 10 min inactivity |
| Dimensions & Weight | Compact, handheld design (<200 g) |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYK-221S |
| Pricing | Upon Request |
| Detection Principle | Colorimetric Chemical Reaction (Modified Spectrophotometric Endpoint) |
| Lower Detection Limit | 0.05 mg/m³ |
| Measurement Range | 0.00–1.00 mg/m³ |
| Accuracy | ±5% of Full Scale |
| Power Supply | 9 V Alkaline Battery (≥40 h continuous operation) |
| Auto-Power-Off | Activated after 10 min inactivity |
| Dimensions & Portability | Compact handheld form factor, <300 g mass, ergonomic field-deployable design |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GDYK-401RC |
| Detection Principle | Colorimetric Method |
| Measurement Range | Formaldehyde: 0.00–2.00 mg/m³ |
| Ammonia | 0.00–5.00 mg/m³ |
| Benzene & BTEX | 0.00–1.00 mg/m³ |
| TVOC | 0.00–4.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Repeatability | ≤ ±5% |
| Sampling Method | Pump-aspirated |
| Response Time (Formaldehyde) | 22 min |
| Operating Temperature | 10–40 °C |
| Relative Humidity Range | 15–95% RH |
| Detection Limits | Formaldehyde: 0.01 mg/m³ |
| Ammonia | 0.10 mg/m³ |
| Benzene & BTEX | 0.05 mg/m³ |
| TVOC | 0.05 mg/m³ |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-1000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Specificity | Soy Sauce Only |
| Detection Time | 30 minutes |
| Detection Range | 0.0–2.0 g/100 mL |
| Detection Limit | 0.1 g/100 mL |
| Accuracy | ±2% |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with Data Logging, Parameter Configuration, Statistical Processing, and RS232 Communication |
| Sample Prep | Integrated Dedicated Pretreatment Module + Single-Use Reagent Cartridge Kit |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M (50 Parameters) |
| Price Range | USD 7,000 – 14,000 |
| Function Type | Multi-Analyte (Simultaneous Quantitative Screening) |
| Sample Applicability | Universal for Solid, Semi-Solid & Liquid Food Matrices |
| Optical Wavelength Range | 400 nm – 630 nm |
| Typical Analysis Time per Parameter | 3–10 minutes |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-103SC |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Matrix (Solid & Liquid) |
| Optical Wavelength | 538 nm |
| Detection Limit | 10.0 mg/kg (solid), 1.00 mg/L (liquid) |
| Quantification Range | 0.0–600.0 mg/kg (solid), 0.0–60.0 mg/L (liquid) |
| Accuracy | ±5% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 310 × 225 × 125 mm |
| Weight | <1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYQ-110S2 |
| Function Type | Multi-analyte (Methanol + Ethanol) |
| Sample Format | Single-sample dedicated format |
| Wavelengths | 412 nm, 595 nm |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SE2 |
| Function Type | Multi-analyte (POD, TVB-N, pH) |
| Sample Compatibility | Universal for raw meat, poultry, and aquatic products |
| Detection Limits | POD Absorbance ≥0.010 A |
| pH Resolution | 0.1 unit |
| Measurement Ranges | POD: 0.000–2.000 A |
| TVB-N | 0.0–150.0 mg/100g |
| pH | 0.2–14.0 |
| Accuracy | ±10% of full scale (per GB/T 5009.44-2003 validation protocol) |
| Interface | RS-232 & USB 2.0 |
| Data Handling | On-device storage, print output, PC synchronization |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SF |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Multi-Sample Universal Format |
| Detection Time | 10 minutes |
| Detection Limit | 0.1 mg KOH/g |
| Measurement Range | 0.0–30.0 mg KOH/g |
| Accuracy | ±5% (Relative Standard Deviation) |
| Reference Standard | GB/T 5009.37–2003 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-110SG |
| Function Type | Single-Analyte Quantitative Detection (Fatty Acid Value) |
| Sample Compatibility | Multi-sample Universal (Paddy Rice, Milled Rice, Rice Flour, and Processed Rice Products) |
| Detection Principle | Micro-titration with Standardized KOH Solution |
| Lower Detection Limit | 5.0 mg KOH / 100 g |
| Measurement Range | 0.0–500.0 mg KOH / 100 g |
| Construction | Chemically Resistant Housing & Precision Micro-burette Assembly |
| Regulatory Alignment | Designed for compliance with GB/T 20569–2006 (Chinese National Standard for Fatty Acid Value Determination in Stored Rice) and supports GLP-aligned documentation workflows |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-4000S |
| Function Type | Single-Analyte Detection (Iodine) |
| Sample Versatility | Multi-Sample Compatible |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–80.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤3 minutes per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging, parameter configuration, statistical processing, and RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-501S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Compatibility | Universal for Food & Biological Matrices |
| Wavelength Range | 400–700 nm |
| Throughput | 96-well plate in 5 seconds |
| Optical Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Photometric Repeatability | ≤ ±1% |
| Linearity | ±1% (0.000–2.000 A) |
| Absorbance Range | 0.0000–4.0000 A |
| Measurement Modes | Single-, Dual-, and Multi-Wavelength |
| Built-in Oscillation | Adjustable speed & duration |
| Interface | RS232 serial port, parallel port |
| Power Supply | AC 220 V / 110 V ±22 V, 50 Hz / 60 Hz ±1 Hz |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SA |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Method (Nessler Reagent) |
| Measurement Range | 0.00–5.00 mg/L as N |
| Accuracy | ±5% |
| Detection Limit | 0.10 mg/L as N |
| Light Source Wavelength | 430 nm |
| Compliance Standard | GB/T 5750.5–2006 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Analyzer |
| Model | GDYS-101SN2 |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Measured Parameter | Free Residual Chlorine |
| Measurement Range | 0.00–5.00 mg/L |
| Accuracy | ±5% of reading |
| Detection Limit | 0.05 mg/L |
| Analysis Time | ≤3 minutes per sample |
| Reagent Format | Single-use, pre-calibrated DPD reagent vials |
| Compliance | Designed for field-deployable water quality screening in accordance with standard methods aligned with APHA 4500-Cl G, ISO 7393-2, and EPA Method 334.0 |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Model | GDYS-101SN3 |
| Measurement Parameter | Free Residual Chlorine |
| Measurement Range | 0.00–2.50 mg/L |
| Accuracy | ±5% |
| Detection Limit | 0.01 mg/L |
| Light Source | High-Brightness LED |
| Wavelength | 520 nm |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYS-101SX |
| Pricing | Available Upon Request |
| Detection Limit | 0.01 mg/L |
| Measurement Range | 0.00–0.40 mg/L |
| Accuracy | ±5% |
| Method Compliance | GB/T 5750.5–2006 |
| Analysis Time | ≤20 minutes per sample |
| Reagent Format | Single-use, pre-packaged test kits |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-102SL2 |
| Price | Upon Request |
| Light Source | High-brightness LED |
| Wavelength | 470 nm |
| Detection Limit | 0.5 mg/L |
| Measurement Range | 0.0–4.0 mg/L |
| Accuracy | ±5% |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Brand | Jiada Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | GDYS-103SI |
| Detection Principle | Colorimetric Endpoint Titration with Integrated Micro-Dosing System |
| Detection Limit | 0.5 mg/L as CaCO₃ |
| Measurement Range | 0.00–8.00 mg/L as CaCO₃ |
| Reagent Format | Pre-packaged Single-Use Vials |
| Enclosure | Rugged ABS Hand-Carry Case with Foam Inserts |
| Compliance | Designed to support ASTM D1067 and ISO 9963-1 field-adapted protocols |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Water Quality Analyzer |
| Model | GDYS-104SI |
| Detection Target | Bromate (BrO₃⁻) |
| Measurement Range | 0.004–0.040 mg/L |
| LOD | 0.004 mg/L |
| Accuracy | ±0.001 mg/L |
| Analysis Time | ≤30 min (sample-to-result) |
| Light Source Lifetime | ≥100,000 hours |
| Control System | Embedded Microcontroller |
| Display | Large LCD Screen |
| Data Output | Built-in Thermal Printer Support |
| Regulatory Context | Designed for compliance with GB/T 5750.10–2023 (China Standard Methods for Examination of Drinking Water – Disinfection By-products), suitable for routine monitoring under ISO/IEC 17025-accredited laboratories |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-104SM |
| Light Source | High-brightness LED |
| Wavelength | 510 nm |
| Detection Limit | 5 mg/L |
| Measurement Range | Low Range: 5.0–500.0 mg/L |
| High Range | 0.05–65% (requires sample dilution) |
| Accuracy | ±5% |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-104SN |
| Light Source | High-Brightness LED |
| Wavelength | 430 nm |
| Detection Limit | 1.0 mg/L |
| Measurement Range | 0.0–50.0 mg/L |
| Accuracy | ±5% |
| Power Supply | DC 9 V |
| Dimensions | 190 × 110 × 95 mm |
| Weight | 0.4 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Model | GDYS-302S |
| Instrument Type | Portable/handheld water quality analyzer |
| Detection Parameters | Ammonia nitrogen (NH₃-N), Nitrite nitrogen (NO₂⁻-N), Nitrate nitrogen (NO₃⁻-N) |
| Optical Source | High-brightness LED |
| Wavelengths | 430 nm, 538 nm |
| LOD | NH₃-N: 0.1 mg/L (as N), NO₂⁻-N: 0.01 mg/L (as N), NO₃⁻-N: 0.5 mg/L |
| Measurement Ranges | NH₃-N: 0.00–5.00 mg/L (as N), NO₂⁻-N: 0.00–0.40 mg/L (as N), NO₃⁻-N: 0.0–20.0 mg/L |
| Accuracy | ±5% FS |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% or rechargeable Li-ion battery (7.4 V, 900 mAh) |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYS-501M |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurable Parameters | Nitrite Nitrogen (A & B), Dissolved Oxygen, Sulfide, Ammonia Nitrogen, Nitrate Nitrogen, Volatile Phenols, Temperature, pH, Salinity |
| Light Source | High-Brightness LEDs |
| Wavelengths | 430 nm, 520 nm, 538 nm, 630 nm |
| Detection Limits | Nitrite-N (A): 0.01 mg/L |
| Nitrite-N (B) | 0.001 mg/L |
| DO | 0.1 mg/L |
| Sulfide | 0.02 mg/L |
| NH₃-N | 0.10 mg/L |
| NO₃⁻-N | 0.5 mg/L |
| Volatile Phenols | 0.10 mg/L |
| Temp | ±0.2 °C |
| pH | ±0.2 |
| Salinity | ±0.2% |
| Measurement Ranges | Nitrite-N (A): 0.00–0.40 mg/L |
| Nitrite-N (B) | 0.000–0.100 mg/L |
| DO | 0.0–10.0 mg/L |
| Sulfide | 0.00–1.00 mg/L |
| NH₃-N | 0.00–5.00 mg/L |
| NO₃⁻-N | 0.0–20.0 mg/L |
| Volatile Phenols | 0.10–5.00 mg/L |
| Temp | −50 to +300 °C |
| pH | 0.2–14.0 |
| Salinity | 0.2–28.0% |
| Accuracy | ±5% FS |
| Power Supply | AC Adapter (220 V ±10%, 50 Hz ±1 Hz) or Rechargeable Li-ion Battery (7.4 V, 900 mAh) |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Brand | Jiada Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYS-601S |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurable Parameters | Nitrite Nitrogen, Ammonia Nitrogen, Dissolved Oxygen, pH, Salinity, Temperature |
| Measurement Range | Nitrite-N: 0.01–0.40 mg/L |
| Ammonia-N | 0.1–9.0 mg/L |
| DO | 0.1–10.0 mg/L |
| pH | 0.0–14.0 |
| Salinity | 0.2–28% |
| Temperature | −50 to +150 °C |
| Accuracy | Nitrite-N: ±5% |
| Ammonia-N | ±5% |
| DO | ±5% |
| pH | ±0.2 |
| Salinity | ±2% |
| Temperature | ±1% |
| Analysis Time | 3–20 min per parameter |
| Methodology | Standardized Colorimetric Methods (GB-based) |
| Reagent Format | Single-use, parameter-specific test kits |
| Display | Direct digital concentration readout |