Jipeng
Filter
Showing all 3 results
| Brand | Jipeng |
|---|---|
| Origin | Shanghai, China |
| Model | BT-100ST |
| Pump Head | YZ1515 |
| Flow Range | 0.06–2290 mL/min |
| Speed Range | 0.1–350 rpm (bidirectional) |
| Display | 4.5-inch HD capacitive touchscreen (Chinese UI) |
| Flow Accuracy | ±0.5% |
| Maximum Pressure | ≥3 kg/cm² |
| Compatible Tubing | #13, #14, #16, #17, #18, #19, #25 |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 330 × 170 × 170 mm |
| Weight | 3.56 kg |
| Control Interface | External TTL-level start/stop trigger |
| Calibration Function | Yes |
| Memory Retention | Yes (parameter auto-save on power-off) |
| Full-Speed Mode | One-button activation |
| Timing Resolution | 0.1 s (operation), 1 ms (internal) |
| Dispensing Range | 0.1 mL – 99999.9 mL |
| Timer Range | 0.1 s – 99999.999 h |
| Sleep Timer | 0 s – 9 h 59 min 59 s |
| Distribution Cycles | 0–9999 (0 = continuous) |
| Distribution Interval | 0–6553.5 s |
| Brand | Jipeng |
|---|---|
| Origin | Shanghai, China |
| Model | HL-2S |
| Pump Type | Peristaltic Pump |
| Flow Rate Range | 2 × (0.5–900) mL/h |
| Speed Range | 0–65 rpm |
| Pressure Rating | ≥3 kg/cm² |
| Display | Gold LED Digital Display |
| Pump Head | Dual-channel, 6-roller, PTFE-lined |
| Tube Compatibility | 1.2×3 mm and 3×5 mm silicone/PTFE tubing |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (L×W×H) | 125×150×180 mm |
| Weight | 1.5 kg |
| Direction Control | Reversible (forward/reverse) |
| External Control Interface | Yes |
| Housing Material | ABS plastic, injection-molded, ergonomic 80° angled panel |
| Brand | Jipeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2880Plus |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 3096(H) × 2080(V), 6.4 Megapixels |
| Bit Depth | 16-bit |
| Dynamic Range | 4.5 OD |
| CCD Sensor Size | 1/2.5" |
| Detection Sensitivity | ≤ 0.01 ng double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | ≥ 56 dB |
| Lens | Motorized optical zoom lens, 8–48 mm, 6× zoom, f/1.2 aperture |
| Transmission UV Source | 302 nm (standard), optional 254 nm / 365 nm reflectance UV |
| Transilluminator Area | 210 × 260 mm (UV), 210 × 300 mm (blue/white light panel) |
| Filter | Standard 590 nm emission filter, compatible with EB, SYBR Safe, GoldView, and other common nucleic acid stains |
| Software | JP-GEL 1D Image Analysis Suite |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 380 × 430 × 730 mm |
| Weight | 18.1 kg |