KA Imaging
Filter
Showing all 5 results
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BrillianSe |
| Quotation | Upon Request |
| Detector Type | High-Resolution CMOS Semiconductor Chip |
| Scanning Method | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| X-ray Energy Range | Up to 120 kV |
| Spatial Resolution | Up to 5.6 µm (0.1 MTF at 90 cycles/mm) |
| Dimensions | 269 mm × 245 mm × 117 mm (L × W × H) |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Model | inCiTe 3D |
| Detector Type | High-Resolution CMOS-Based Direct-Conversion a-Se (BrillianSe) Sensor |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Up to 5.6 μm (0.1 MTF at 90 cycles/mm) |
| X-ray Energy Range | 40–110 kV |
| Field of View | 32 mm × 32 mm (direct detection) |
| Maximum Sample Dimensions | Ø25 mm × 100 mm (diameter × height/length) |
| System Footprint | 1500 mm × 580 mm × 500 mm (L × W × H) |
| Pixel Pitch | 8 μm |
| Detector Resolution | 4096 × 4096 (16.8 MP) |
| Effective DQE | High across 40–120 keV |
| Phase-Contrast Mechanism | Propagation-Based (Grating-Free, In-Line) |
| Minimum Focal Spot Size | 2 μm |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | inCiTe |
| Detector Type | High-Resolution CMOS-Based Direct-Conversion Semiconductor Detector (BrillianSe™) |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | Up to 5.6 µm (0.1 MTF at 90 cycles/mm) |
| X-ray Source Spot Size | ≤5 µm |
| X-ray Energy Range | 40–100 kV |
| Maximum Sample Volume | Ø25 mm × 100 mm (diameter × height/length) |
| System Dimensions | 1500 mm × 580 mm × 500 mm (L × W × H) |
| Pixel Pitch | 8 µm |
| Detector Format | 16 MP (4096 × 4096) |
| Field of View | 32 mm × 32 mm |
| Phase-Contrast Mechanism | Propagation-Based (Grating-Free, In-Line) |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Model | Reveal 35C |
| Compliance | ASTM F792222-17 |
| Detector Architecture | Triple-layer stacked scintillator design |
| Imaging Modes | Single-exposure spectral DR (conventional DR, low-density image, high-density image) |
| Connectivity | Wireless (Wi-Fi 5/6), USB-C interface |
| Form Factor | Portable, battery-operated (optional), ruggedized enclosure for field NDT use |
| Software | SpectralDR® acquisition and material-separation suite with color-coded density mapping |
| Brand | KA Imaging |
|---|---|
| Origin | Canada |
| Model | REVEAL R 35C |
| Detection Principle | Spectral Digital Radiography (SpectralDR®) |
| Energy Discrimination | Triple-energy single-exposure acquisition |
| Connectivity | Wireless (Wi-Fi 6) |
| Compliance | ASTM F792–22 (formerly F792222-17) |
| Portability | Integrated battery-powered operation, ruggedized IP54 enclosure |
| Software Platform | Reveal™ Acquisition & Analysis Suite v4.2 |