KANOMAX
Filter
Showing all 8 results
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6822 / 6824 |
| Instrument Type | Vane Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.2–20.0 m/s |
| Accuracy | ±3% of reading or ±0.1 m/s (whichever is greater) |
| Operating Temperature | −20 to +100 °C |
| Operating Humidity | 5.0–95.0 %RH |
| Temperature Accuracy | ±1.0 °C |
| Probe Diameter | 70 mm |
| Power Supply | 3 × AA batteries |
| Battery Life | Approx. 150 hours |
| Dimensions (W×H×D) | 81 × 165 × 38 mm |
| Weight | 175 g (including batteries) |
| Air Volume Range | 0–9,999 CFM |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 6850+ |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Flow Rate Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage | 10,000 records with USB export capability |
| Measurement Media | Air and non-corrosive gases |
| Brand | Kanomax |
|---|---|
| Model | DALT6900 |
| Flow Range (Matrix) | 36–640 m³/h |
| Flow Range (Nozzle) | 4–36 m³/h |
| Flow Accuracy | ±2.5% of reading ±0.1 m³/h |
| Flow Resolution | 0.01 m³/h |
| Static Pressure Range | ±2500 Pa |
| Pressure Accuracy | ±1% of reading ±1 Pa |
| Pressure Resolution | 0.1 Pa |
| Temperature Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Barometric Pressure Range | 70–130 kPa |
| Baro Accuracy | ±2% of reading |
| Baro Resolution | 0.1 kPa |
| Power Supply | DALT6900-0E: 110–120 V, 1Φ, 50/60 Hz, 16 A |
| DALT6900-1E | 220–240 V, 1Φ, 50/60 Hz, 10 A |
| Net Weight | ~72 kg |
| Dimensions (W×D×H) | 54×50×120 cm |
| Data Storage | 1000 test records |
| Display | 5-inch color LCD touchscreen |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA HVAC Air Duct Leakage Testing Standard, GB 50243–2002 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KAN-1000 |
| Compliance Standards | EN 1507:2006, EN 12237:2002, Eurovent 2/2, DW/143, SMACNA Duct Construction Standards, GB 50243–2002 |
| Pressure Range | ±5000 Pa (adjustable) |
| Flow Measurement Range | 0.1–3000 m³/h (dependent on duct size and test configuration) |
| Data Storage | 1000 test records |
| Display | 4.7-inch capacitive touchscreen LCD |
| Environmental Operating Range | 0–40 °C, 10–90 % RH (non-condensing) |
| Interface | USB port for data export |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Certifications | CE, RoHS, ISO 9001-manufactured design |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KAN-7600 |
| Quotation | Upon Request |
| Airflow Range | 100–500 m³/h |
| Max. Cabin Static Pressure | ±2500 Pa (adjustable) |
| Standard Nozzle Diameters | Φ41 mm & Φ39 mm |
| Pressure Measurement Port | Integrated static pressure tap on flange |
| Control Method | Inverter-driven variable-speed blower with real-time feedback loop |
| Compliance | JIS D 1622 (Automotive Ventilation Performance Test), JIS B 8330 (Blower Testing and Inspection) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | Up to 7 h (battery) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Time Interval Setting | 10 s–1 h |
| Delay Start | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous mode |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Exhaust Filtration | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6113 |
| Instrument Type | Thermal Anemometer |
| Measurement Range | 0.1–50.0 m/s |
| Accuracy | ±(3% of reading + 0.1) m/s |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Pressure Range | −5 to +5 kPa |
| Pressure Accuracy | ±(3% of reading + 0.01) kPa |
| Data Storage Capacity | 100 sets |
| Communication Interface | RS-232C |
| Analog Output | 0–1 V (optional) |
| Built-in Thermal Printer | Yes |
| Power Supply | 6 × AA batteries |
| Dimensions | 210 × 120 × 133 mm |
| Weight | 1.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6850 |
| Measurement Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Wind Speed Range | 0.20–60.0 m/s |
| Wind Speed Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Wind Speed Resolution | 0.01 m/s |
| Airflow Volume Range | 0–999,999 m³/h |
| Airflow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive (FAT32 formatted) |