| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200R |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | Standard 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| Refractive Index (RI) Detection Range | 1.00–1.75 RIU |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aseeker-100Plus |
| Instrument Category | Fast Liquid Chromatography System |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure Rating | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Injection Vial Capacity | 2 mL |
| Temperature Control Range | 10–50 °C |
| Wavelength Detection Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Pump Flow Range | 0.1–50 mL/min |
| Standard Extraction Cell Volume | 40 mL (optional: 10 mL / 20 mL) |
| Standard Collection Vial Volume | 250 mL (optional: 60 mL) |
| Solvent Mixing Capability | Up to 4 solvents |
| Typical Extraction Duration | 20–30 min |
| Solvent Consumption | ~10 mL per 10 g sample |
| Required Gas Supply | Nitrogen, 0.4–1 MPa |
| Max Power Consumption | 600 W |
| Electrical Input | 100–240 VAC ±10%, 50–60 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aseeker-350Plus |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Temperature Control Range | 10–50 °C |
| Wavelength Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Cell Volume (Standard) | 120 mL |
| Pressure Accuracy | ±0.3 MPa |
| Temperature Accuracy | ±0.5 °C |
| Solvent Channels | 4 |
| Simultaneous Extraction Positions | 5 |
| Extraction Time per Batch (5 samples) | ≤20 min |
| Power Consumption | ≤1.7 kW |
| Gas Supply Requirement | N₂, 0.4–1 MPa |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aseeker-600 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 20 mL / 40 mL |
| Throughput | 6 samples in 20 min |
| Dimensions (W×D×H) | 770 mm × 608 mm × 755 mm |
| Weight | 95 kg |
| Solvent Consumption per Sample | 5–200 mL |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Requirement | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.7 kW |
| Gas Supply | Lab-grade nitrogen, 0.4–1 MPa |
| Solvent Mixing Capability | Up to 4 solvents |
| Collection Vial Capacity | 250 mL |
| Cleaning Stations | 6 |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | CoolMax-3000 |
| Price | USD 28,000 (approx.) |
| 雾化方� | �: FocusJet coaxial flow design |
| 流动相流速 | 0.2–2 mL/min |
| 材料 | 316 stainless steel, PEEK, fused silica, PTFE |
| 数字数据采集速率(最大) | 100 Hz |
| 数字噪声滤波 | 4th-order low-pass Bessel filter |
| 模拟信号输出 | 0–1 V DC (optional) |
| 蒸发温度 | 35 °C or 50 °C |
| 预热时间 | <15 min to 35 °C |
| 气体进口压力 | 70–80 psi (0.4–0.5 MPa) |
| 气体消耗 | 4 L/min |
| 气体压力控制 | Manual |
| 控制方� | �: PC + touchscreen interface |
| 氮气发生器原理 | Membrane separation |
| 氮气输出流量 | 5 L/min |
| 氮气输出压力 | 0.6 MPa |
| 氮气纯度 | 99.9% |
| 露点 | −45 °C |
| AD转换器 | 24-bit |
| 检测限 | pg-level |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–120 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 145 psi (1.0 MPa) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU @ 254 nm |
| Fraction Collection | X-Y Robotic Matrix with 135-tube Capacity (standard 15 × 150 mm tubes) |
| Detection Options | Dual-Wavelength UV Detector (D₂ + Tungsten lamp) |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000Pro |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–200 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 200 psi (13.8 bar) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU/30 min @ 254 nm |
| Flow Path Configuration | Binary Solvent Delivery |
| Fraction Collection | X-Y Robotic Matrix (135-tube capacity, standard 15 × 150 mm tubes) |
| Detection Options | UV/Vis Detector (D₂ + Tungsten lamp), optional ELSD |
| Column Compatibility | Normal-phase (e.g., silica, 12 g & 25 g), reversed-phase (C18, 40 g), and empty loading columns (12 g) |
| Software Features | Method-based fraction triggering, peak integration & quantitation, audit trail, user management, lamp life monitoring, intensity calibration, TLC-guided method recommendation |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | FlashDoctor-1500 |
| Instrument Type | Medium-Pressure Flash Chromatography System |
| Application Scope | General-Purpose Preparative Purification |
| Flow Rate Range | 0–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Accuracy | ±1.5% |
| Injection Capacity | Manual or Optional Autosampler |
| Injection Volume Range | 0.1–50 mL (via syringe or loop) |
| Temperature Control | Ambient-only (no active column oven) |
| Wavelength Range (DAD) | 200–800 nm |
| Data Acquisition Rate | Up to 20 Hz |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-2000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±2.0% |
| Flow Precision | <1.5% |
| Maximum Pressure | 300 psi (2.07 MPa) |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Spectral Bandwidth | 8 nm |
| Flow Cell Path Length | 0.3 mm |
| Detection Modes | UV-Vis (DAD), optional ELSD |
| Fraction Collection | 2D X-Y robotic collector (135-tube capacity, standard 15 × 150 mm tubes) |
| Column Compatibility | Reversible normal-phase and reversed-phase (e.g., C18), flash columns up to 40 mm ID |
| Software Compliance | Audit trail, user management, electronic signature support per FDA 21 CFR Part 11 requirements |
| System Architecture | Integrated benchtop unit, ventilated cabinet compatible |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-1000 |
| Flow Rate Range | 0–10 mL/min |
| UV Detection Wavelength | 254 nm |
| Column Dimensions | 25 × 400 mm |
| Packing Material | Bio-Beads S-X3, 200–400 mesh |
| Solvent System | Ethyl Acetate–Cyclohexane (1:1 v/v) |
| Standard Loop Volume | 5 mL |
| Pump Type | Precision Plunger Pump |
| Detector Type | Single-Wavelength UV Detector |
| Sample Introduction | Manual Injection Valve with Solvent Recovery Three-Way Valve |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-2000 |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | Not Specified |
| Flow Stability | High (Dual-Piston Pump Architecture) |
| UV Detector Wavelength Range | 190–800 nm |
| GPC Column | 20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), Eluent: Ethyl Acetate/Cyclohexane (3:7 v/v) |
| Fraction Collector | Standard 160-position rack for 20 mL tubes |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-3000 |
| Flow Rate | 0–10 mL/min |
| Max Pressure | 1 psi |
| Flow Stability | ±0.5% RSD |
| Auto-sampler Volume | 5 mL (standard loop, customizable) |
| Auto-sampler Capacity | 160 × 20 mL tubes (standard) |
| UV Detection Range | 190–800 nm |
| Column Dimensions | 20 × 300 mm |
| Packing Material | Bio-Beads S-X3 (200–400 mesh) |
| Solvent System | Ethyl Acetate/Cyclohexane (3:7 v/v) |
| Fraction Collector Options | 20 mL (160-position), 80 mL (40-position), 150 mL (12-position), 250–300 mL (8-position) |
| Solvent Recovery Valve | Integrated three-way valve for solvent recycling |
| [Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-5000 |
| Automation Level | Fully Automated |
| Channel Count | 12 parallel channels |
| Extraction Format | Cartridge-based SPE |
| Flow Rate Control | 0.1–120 mL/min |
| Solvent Selection Capacity | Up to 8 solvents (standard configuration: 7) |
| Sample Throughput | 12 samples per run |
| Sample Load Volume | 1 mL to unlimited |
| Wetted Materials | Stainless steel (316), PTFE, borosilicate glass |
| Pressure Output Range | 0–30 psi (0–2.07 bar) |
| Input Max | 100 psi (6.9 bar) |
| Valve Type | Non-metallic 12-position rotary valve |
| Syringe Pump Volume | 10 mL per channel |
| Positioning Accuracy | ±0.1 mm |
| Liquid Handling Accuracy | ≥99% |
| Fraction Collection Volumes | Standard 15 mL (customizable) |
| Data Interface | USB |
| Operating System Compatibility | Windows XP/7/8 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AllSmall-40 |
| Instrument Type | Automated Stomacher-Type Homogenizer |
| Effective Volume | 3–400 mL |
| Timer Range | 0–999 s |
| Adjustable Speed | 0–9 strokes/sec |
| Display | LCD |
| Motor Power | 200 W |
| Dimensions (W×D×H) | 450 × 270 × 290 mm |
| Weight | 16.5 kg |
| Power Supply | 220 V / 50 Hz |
| Stomacher Bag Size | 30 × 170 mm |
| Safety | Hall-effect interlock door switch |
| Material | Full stainless steel construction |
| Bag Compatibility | Disposable sterile filter bags (30 × 170 mm) |
| Cleaning | Fully opening door + transparent viewing window |
| Waste Containment | Integrated leak-proof waste tray |
| Sample Isolation | Non-contact homogenization (no internal wetted parts) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Anters-1500G |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–10 mL/min |
| Pump Pressure Range | 0–40 MPa |
| Refractive Index Detector Drift | <1×10⁻⁷ RIU/h |
| RI Detector Cell Volume | 9 µL |
| UV Detector Wavelength Range | 100–200 nm |
| UV Detector Noise | <0.25×10⁻⁵ AU |
| Column Oven Temperature Range | 4 °C to 40 °C above ambient |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Anters-1500G (with Column Kit) |
| Instrument Type | High-Temperature GPC System |
| Key Specifications | Pump Flow Range: 0.001–10 mL/min |
| Max Pressure | 40 MPa |
| Flow Precision | <0.3% RSD |
| Flow Accuracy | <0.06% |
| Autosampler Capacity | 144 × 2 mL vials (standard) |
| Injection Volume | 0.1–100 µL |
| Injection Precision | <0.3% RSD |
| Carryover | <0.1% |
| Column Oven Temp Range | 4–100 °C |
| Temp Stability | ±0.15 °C |
| RI Detector Range | 1.00–1.75 RIU |
| Noise | ≤5×10⁻⁷ RIU |
| Drift | ≤5×10⁻⁶ RIU/30 min |
| Flow Cell Volume | 8 µL |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Aseeker-100 |
| Instrument Category | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 11 mL / 22 mL / 33 mL |
| Collection Vial Capacities | 40 mL / 60 mL |
| Solvent Flow Rate | 0.1–50 mL/min |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Gas Supply Requirement | Nitrogen, 0.4–1 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max. Power Consumption | 600 W |
| Dimensions (W×D×H) | 450 mm × 500 mm × 530 mm |
| Weight | 30 kg |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection with automatic shutdown, liquid-level sensing with overflow prevention, integrated post-extraction filtration |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aseeker-200 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 34 mL / 66 mL / 100 mL |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Pump Flow Rate | 0.1–50 mL/min |
| Collection Vial Capacities | 60 mL / 250 mL |
| Gas Supply Requirement | Nitrogen at 0.9–1.2 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.2 kW |
| Dimensions (W×D×H) | 508 mm × 485 mm × 745 mm |
| Weight | 40 kg |
| Wetted Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection, liquid-level sensing, pressure-deficiency alarm, automatic filtration post-extraction, dual-needle purge system to prevent splashing |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Aseeker-500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 10 MPa (±0.5 MPa) |
| Extraction Cell Volume | Standard 34 mL (optional: 1, 5, 10, 22, 66, 100 mL) |
| Extraction Time per Sample | 20 min |
| Instrument Dimensions | 800 mm × 738 mm × 685 mm |
| Sample Capacity | 24 extraction cells |
| Collection Vials | Standard 19 × 250 mL or up to 28 × 60 mL + 5 × 250 mL with adapter |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Consumption | ≤1.2 kW |
| Input Voltage | 100–240 VAC ±10 %, 50–60 Hz |
| Solvent Mixing Capability | Up to 4 solvents |
| Cleaning Stations | 2 |
| Weight | 70 kg |
| Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Electronic over-pressure/over-temperature protection, leak detection with automatic shutdown and sequence bypass, external air supply pressure monitoring, infrared liquid-level sensing at collection vials |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CoolMax-2000 |
| Price | ¥200,000 |
| Nebulization Method | FocusJet concentric flow design |
| Mobile Phase Flow Rate | 0.2–2 mL/min |
| Construction Materials | 316 stainless steel, PEEK, fused silica, PTFE |
| Digital Data Acquisition Rate (max) | 100 Hz |
| Digital Noise Filtering | 4th-order low-pass Bessel filter |
| Analog Output Option | 0–1 V DC |
| Evaporation Temperature Settings | 35 °C or 50 °C |
| Preheat Time to 35 °C | <15 min |
| Gas Inlet Pressure | 70–80 psi (0.4–0.5 MPa) |
| Gas Consumption | 4 L/min |
| Gas Pressure Control | Manual |
| Control Interface | PC + integrated touchscreen |
| AD Converter Resolution | 24-bit |
| Detection Limit | pg-level |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 195–650 nm (Excitation), 200–800 nm (Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Flow Rate Range | 0–10 mL/min |
| Flow Accuracy | ±0.3% |
| Flow Precision (RSD) | ≤0.1% |
| Injection Valve Pressure Rating | 35.0 MPa (5000 psi) |
| Spectral Bandwidth | 10 nm / 20 nm |
| AD Resolution | 24-bit |
| Software Platform | FStar-2000 Chromatography Data System (CDS) for Windows 7/8/10 |
| Compliance | Fully aligned with Chinese Pharmacopoeia (2015 Edition), GLP/GMP principles, and FDA 21 CFR Part 11 audit trail requirements |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-4000 |
| Flow Rate | 0–50 mL/min |
| Auto-sampler Volume | 5 mL standard loop (customizable), 66-position 20 mL vial tray |
| Fraction Collector Capacity | 96-position 60 mL vial tray (customizable) |
| UV Detection Wavelength Range | 190–800 nm |
| GPC Column | 20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), eluent: ethyl acetate/cyclohexane (3:7, v/v) |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodSee-20E |
| Instrument Type | TLC Imaging System |
| Imaging Wavelengths | 254 nm UV, 365 nm UV, Visible Light |
| Maximum Imaging Area | 200 × 200 mm |
| Camera Resolution | ≥12 MP |
| Power Supply | 220 V, 50 Hz, 90 W |
| Light Source Power | 30 W per channel |
| Scanning Speed | Up to 100 mm/s |
| Interface | USB |
| Software Platform | Windows 7 / 10 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Optional Nitrogen Purge |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GOODSPE-1200 |
| Automation Level | Fully Automatic |
| Channel Count | 1 |
| Extraction Mode | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min |
| Solvent Selection | 5 Independent Solvent Channels |
| Sample Capacity | Up to 288 Samples per Unattended Run |
| Sample Loading Volume | 20 mL – 20 L |
| Wetted Materials | PTFE, Borosilicate Glass |
| Valve Type | Non-Metallic 12-Port Rotary Valve |
| Pressure Output | 0–30 psi (0–1.4 bar) |
| Air Injection | Integrated 10 mL Air Syringe |
| Liquid Injection | Integrated 10 mL Liquid Syringe |
| Positioning Accuracy | 0.1 mm |
| Dispensing Accuracy | ≥99% |
| Data Interface | USB |
| Operating Voltage | 100–240 V AC, 50/60 Hz |
| Compliance | EPA Method-Compliant for Aqueous Matrix Analysis (e.g., EPA 508, 525.3, 8270) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GOODSPE-2000 |
| Price Range | USD 14,000–35,000 (FOB Shanghai) |
| Automation Level | Fully Automated |
| Channel Configuration | Single-Channel (Optional Dual-Channel) |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min |
| Solvent Selection Capacity | Up to 12 Solvents via Non-Metallic 12-Port Valve |
| Sample Throughput | 40 Samples per Batch |
| Sample Loading Volume | 1–50 mL |
| Wetted Materials | Borosilicate Glass, PTFE |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GOODSPE-3000 |
| Automation Level | Fully Automated |
| Number of Channels | 4 Parallel Channels |
| Extraction Mode | Cartridge-Based SPE |
| Flow Rate Control | 0–30 mL/min per channel |
| Solvent Selection | Up to 5 Pre-Loaded Solvents (Expandable to 10 via Custom 12-Position Non-Metallic Rotary Valve) |
| Sample Capacity | Up to 144 Sequential Samples |
| Sample Loading Volume | 1–50 mL |
| Wetted Materials | PTFE, Borosilicate Glass |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GOODSPE-3000B |
| Automation Level | Fully Automated |
| Channel Configuration | Modular — configurable as 1-, 2-, or 4-channel |
| Extraction Format | Cartridge-based SPE |
| Flow Rate Control | 0–30 mL/min per channel |
| Solvent Reservoirs | 8 independent solvent ports |
| Maximum Sample Capacity | 144 samples (using 1 mL cartridges) |
| Sample Loading Volume | 1–50 mL per run |
| Wetted Materials | PTFE and borosilicate glass |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-6000 |
| Automation Level | Fully Automatic |
| Channel Count | 6 parallel channels |
| Extraction Mode | Column-based and disk-based SPE |
| Flow Rate Control | 0.1–120 mL/min |
| Solvent Selection | Up to 5 independently programmable solvents |
| Sample Capacity | 6 samples simultaneously |
| Sample Load Volume | 20 mL – 20 L |
| Elution Pump | Dual syringe pump (10 mL liquid + 10 mL air) |
| Contact Materials | PTFE and borosilicate glass |
| Pressure Source | Regulated air supply (0–30 psi / 0–1.4 bar output |
| Valve Type | Non-metallic 12-position rotary valve |
| Waste Separation | Dedicated aqueous and organic waste lines |
| Compliance | EPA Method-compliant for water analysis (e.g., EPA 508, 525.3, 537, 8270) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-80 |
| Automation Level | Fully Automatic |
| Number of Channels | 8 |
| Extraction Mode | Column-Based SPE |
| Flow Rate Control Range | 0.01–15 mL/min |
| Solvent Selection | Up to 4 independent solvent lines |
| Sample Capacity | Simultaneous processing of up to 8 samples |
| Sample Loading Volume | 1–30 mL per channel |
| Wetted Materials | Stainless steel (316), PTFE, borosilicate glass, PEEK |